                                Test and Measurement
                                Division




             Operating Manual


             SIGNAL GENERATOR
             SMG
             8Ol.OOOl.52




Printed in the Federal
Republic of Germany
              Certified Quality System




Qualitatszertifikat                  Certificate of quality                Certificat de qualit6
Sehr geehrter Kunde,                 Dear Customer,                        Cher client,

Sie haben sich fur den Kauf eines    You have decided t o buy a            Vous avez choisi d'acheter un
Rohde & Schwarz-Produktes ent-       Rohde & Schwarz product. You          produit Rohde & Schwarz. Vous
schieden. Hiermit erhalten Sie ein   are thus assured of receiving a       disposez donc d'un produit fabri-
nach modernsten Fertigungsme-        product that is manufactured          que d'apres les methodes les plus
thoden hergestelltes Produkt. Es     using the most modern methods         avancees. Le developpement, l a
wurde nach den Regeln unseres        available. This product was de-       fabrication et les tests respectent
Qualitatsmanagementsystems           veloped,    manufactured       and    nos normes de gestion qualite.
entwickelt, gefertigt und gepruft.   tested in compliance with our         Le systeme de gestion qualite de
Das Rohde 8 Schwarz-Qualitats-       quality management system stan-       Rohde & Schwarz a kt6 homolo-
managementsystem ist nach I S 0      dards.                                gue conformement a la norme
9001 zertifiziert.                   The   Rohde & Schwarz       quality   I S 0 9001.
                                     management system is certified
                                     according t o I S 0 9001.
Safety Instructions
This unit has been designed and tested according to the standards outlined overleaf and has leff the
manufacturer's premises in a state fully complying with the safety standards.

In order to maintain this state and to ensure safe operation, observe the following instructions, symbols
and precautions.

    When the unit is to be permanently cabled, first connect protective ground conductor before
    making any other connections.

    Built-in units should only be operated when properly fitted into the system.

    For permanently cabled units without built-in fuses, automatic switches or similar protective
    facilities, the AC supply line shall be fitted with fuses rated to the units.

    Before switching on the unit ensure that the operating voltage set at the unit matches the line
    voltage.
    If a different operating voltage is to be set, use a fuse with appropriate rating.

    Units of protection class I with disconnectible AC supply cable and plug may only be operated
    from a power socket with protective ground contact.
    The protective ground connection should not be made ineffective by an extension cable.
    Any breaking of the protective ground conductor within or outside of the unit or loosening of the
    protective ground connection may cause the unit to become electrically hazardous.
    The protective ground conductor shall not be interrupted intentionally.

    Before opening the unit, isolate it from the AC supply.
    Adjustment and replacement of parts as well as maintenance and repair should be carried out only
    by specialists approved by R & S.
    Observe safety regulations and rules for the prevention of accidents.
    Use only original parts for replacing parts relevant to safety (e.g. power onfoff switches, power
    transformers or fuses).

    Also observe the additional safety instructions specified in this manual.


Explanation of Symbols Used


A          - Read operating manual, observe the safety symbols used
           - Caution, shock hazard
 A     ,
 @         - Protective ground connection

           - Unit ground
           - Equipotential (floating ground)
                                                    EC Certificate of Conformity




Certificate No.: 9502164


This is to certify that:


             Equipmenttype   Order No.              Desiqation

             SMG-B1          0802.0005.02           Reference Oscillator OCXO
             SMG-B2          0802.0405.02           AF Synhesizer
             SMG-B3          0801.9609.02           X Output


complies with the provisions of the Directive of the Council of the European Union on the
approximation of the laws of the Member States

-   relating to electromagnetic compatibility
    (891336lEEC revised by 91/263/EEC, 92/31IEEC)

Conformity is proven by compliance with the following standards:




Affixing the EC conformity mark as from 1995



                                                 ROHDE & SCHWARZ GmbH & Co. KG
                                                 Miihldorfstr. 15, D-81671 Miinchen

Munich, 27.1 1.95                                Central Quality Management FS-QZ/ Becker
Contents of SMG Manual




Operating Manual

1 . Data Sheet

2.   Preparation for Use and Operating Instructions
3 . Maintenance




Service Manual

4.   Service Manual for Complete Instrument

5.   Service Instructions for the Individual PC Boards
                                              Order No.            Index
     Keyboard/Display  ...................
               ...........................    801.1366.02   ....... 21
                                                            .......
     FRN LOOP
     RF Oscillator
     Output Stage
                    ......................
                   .......................
                                              801.3917.02
                                              801.5110.02   ....... 3
                                                            ....... 45
     Processor  ..........................
                   .......................
                                              801.3217.02
                                              801.2410.02   .......
                                                            ....... 7
     AF Generator
     Power Pack  .........................
     RF Attenuation Set  .................
                                              801.7312.02
                                              801.1614.02
                                              801.1108.02
                                                            ....... 8
                                                            .......
                                                                     6


     Reference Oscillator, OCXO
     (Option SMG-B1)  ....................
     AF Synthesizer (Option SMG-B2, B 2 1 )
                                              802.0005.02
                                              802.0405.02
                                                            ....... 9
                                                            ....... 10
     X Output (Option SMG-B3)  ......,....    801.9609.02   ....... 10
Table of Contents

                                                             Paqe
1          Data Sheet

2          Preparation for Use and Operation

21
 .         Legend to Front and Rear Views Figs 2-1 and 2-2    21
                                                               .

2.2        Preparation for Use  ............................. 2.5
2.2.1      Power Supply Fuse  ............................... 2.5
2.2.2      AC Power Supply  ................................. 2.5
2.2.3      Rack Mounting  ................................... 2.5
           Operation ....................................... 2.6
           Status Upon Switchinq On ........................ 2.13
           Internal/External Reference Frequency ........... 2.14
           Frequency (RF) .................................. 2.16
           Frequency Offset (RF OFFSET) .................... 2.17
           Level ........................................... 2.19
           Level Offset .................................... 2.20
           Non-interruptinq Level Setting .................. 2.21
           Level Control Without Function .................. 2.22
           Level EMF ....................................... 2.22
           Internal AF Modulation Frequency ................ 2.23
           AF Amplitude .................................... 2.25
           Modulation. AM .................................. 2.27
           Modulation. FY .................................. 2.29
           Modulation. O M .................................. 2.31
           Modulation. FSK ................................. 2.33
           Pulse Modulation. PM ........................... 2.34
           Pulse Modulation (Code 29) ...................... 2.34
           Pulse Modulation with Level Control Voltaqe
           from Table ...................................... 2.34b
2.3.16.3   Pulse Modulation (Code 19) ...................... 2.34~
2.3.17     Modulation. External Source ..................... 2.35
2.3.18     Modulation. Two-tone ............................ 2.37
2.3.19     Variation. Rotary Knob .......................... 2.38
2.3.20     Rotary Knob. Step Size .......................... 2.40
2.3.21     Variation. HOLD ................................. 2.41
2.3.22     Variation. AREF ................................. 2.41
2.3.23     Variation. Step ................................. 2.42
                                                             Page


      Sweep (RF)    ................................... .
      Sweep (RF). Parameter Entry     .....................
      Sweep (RF). Operatinq Modes     .....................
      Sweep (RF). Display    .............................
      Sweep (RF). Logarithmic     .........................
      Sweep (AF)    ......................................
      Sweep (AF). Parameter Entry     .....................
      Sweep (AF). Operating Modes     .....................
      Sweep (AF). Display    .............................
      Sweep (AF). Logarithmic     .........................
      Sweep (RF. AF). X Output and Z Output      ...........
      Store   -
              Recall    ..................................
      Sequence    ........................................
      Special Functions    ...............................
      Self-test    .......................................
      Status    ...........................................
      Instrument Preset    ...............................
      IEC-bus Address    .................................
      . Remote Control of Instrument via IEC Bus ........
        Interface Description ...........................
        Setting the Device Address ......................
        Local/Remote Switchover .........................
        Interface Messages ..............................
        Universal Commands ..............................
        Addressed Commands ..............................
        Device Messages .................................
        Commands Received by the SMG in Listener Mode ...
        Messages Transmitted by SMG in Talker Mode ......
        Common Commands .................................
        Device-specific Commands ........................
        Alternatives for the Command Syntax .............
        Service Request and Status Reqister .............
        Timing of Command Processing and Synchronization
        Error Handling ..................................
        Resetting Device Functions ......................


2.5    Options   .........................................   2.108
Contents


                                                                          Page

           Maintenance

                                                                  .....
           R e q u i r e d M e a s u r i n g Equipment and Accessories     3.1

           T e s t i n g t h e Performance Data   .....................    3.3

           D i s p l a y and Keyboard        ............................. 3.3
           Frequency S e t t i n g        ............................... 3.3
           Reference Frequency              .............................. 3.3
           S e t t l i n q Time     .................................... 3.4
           Output Level           ..................................... 3.5
           Attenuation Set              .................................. 3.5
           Non-interrupting Level S e t t i n q        ................... 3.6
                                                      .................... 3.6
           Output R e f l e c t i o n C o e f f i c i e n t
           ~armonics          ........................................ 3.7
           Spurious         ......................................... 3.8
           SSB P h a s e N o i s e      .................................. 3.8
           Broadband N o i s e          .................................. 3.10
           Residual F        M   ...................................... 3.11
           Modulation Generator              ............................. 3.12
           Function T e s t of t h e External Modulation
           Level Monitoring              ................................. 3.12
           AM M o d u l a t i o n Depth     .............................. 3.13
           AM D i s t o r t i o n   .................................... 3.13
           AM F r e q u e n c y Response      ............................ 3.13
           AM DC       ............................................ 3.14
           R e s i d u a l AM    ...................................... 3.14
           I n c i d e n t a l cbM a t AM   ............................. 3.14
           F Deviation Setting
           M                                 ............................. 3.15
           F Distortion
            M                       .................................... 3.15
           F Frequency Response
            M                                 ............................ 3.15
           F r e q u e n c y O f f s e t a t F DC
                                             M    ........................ 3.15
           ~ n c i d e n t a lAM a t F   M  .............................. 3.16
           @ M Deviation S e t t i n g       ............................. 3.16
           @M Distortion            .................................... 3.16
           O M F r e q u e n c y Response     ........................... 3.17
           Overvoltaqe Protection              ........................... 3.17
           P u l s e Modulation          ................................. 3.17
           P e r f o r m a n c e T e s t Report .........................  3.18
2        Preparation for Use and Operation
The values specified in this section are not guaranteed; only the
specifications of the data sheet are binding.
All underlined numbers refer to the items of front and rear
views Figs. 2-1 and 2-2 in the Appendix.


21
 .       Legend to Front and Rear Views Figs 2-1 and 2-2

        Label                     Function

        FREQUENCY                 RF display. Further informa-
                                  tion in section 2.3, Opera-
                                  tion.


        PARAMETER        ON/OFF   The PARAMETER ON/OFF keypad
                                  is used to set the parameter
                                  to which numerical entries
                                  and variations then apply.
                                  Parameters can be switched on
                                  or off using the ON/OFF keys.
                                  Further information in sec-
                                  tion 2.3, Operation.


       MODULATION                 Display of the modulation
                                  depth, deviation and AF.
                                  Further display functions in
                                  section 2.3, Operation.


        DATA        ENTER/UNITS   Numerical keypad for the
                                  parameter set in the PARA-
                                  METER keypad.
                                  Further information in sec-
                                  tion 2.3, Operation.


       AMPLITUDE                  Display of the RF or AF
                                  level. Further display func-
                                  tions in section 2.3, Opera-
                                  tion.
            Function                        I
VARIATION   Keypad to vary the parameter
            set in the PARAMETER keypad
            using the rotary knob or the
            STEP ++ keys.
            Further information in sec-
            tion 2.3, Operation.


SWEEP       Keypad to select the operat-
            ing mode and to switch the
            sweep on and off.
            Further information in sec-
            tion 2.3, Operation.


            BNC output of internal AF
            signal; level adjustable
            with SMG-B2 AF synthesizer
            option. Further information
            in sections "Internal AF
            Modulation Frequency" and
            "AF Arnpli tude"    .
            BNC inputs for external modu-
            lation signals. Input impe-
            dance 100 ki2 ( 6 0 0 a ) .
            Further information in sec-
            tion "Modulation, External
            Source".

POWER       Power switch
                                            I
            RF output,
            N socket 50    Q.



LOCAL       Key for switching to manual
            operation and for entry or
IEC ADDR    display of IEC-bus address.
            Further information in sec-
            tion "IEC-bus Address".
      -

No.   Label                           Function
-
-
13    REMOTE                          LED t o i n d i c a t e t h e remote
                                      state.


      SHIFT                           Key t o s e l e c t t h e SHIFT f u n c -
                                      tions. Further information
                                      i n s e c t i o n 2.3, O p e r a t i o n .


      STATUS                          Key f o r s t a t u s c h e c k or f o r
                                      instrument preset. Further
      INSTR PRESET                    information i n sections
                                      " S t a t u s " and " I n s t r u m e n t
                                      Presetn    .
      MEMORY                          Keypad t o s t o r e i n s t r u m e n t
                                      s e t t i n g s , t o c a l l stored
                                      s e t t i n g s and f o r t h e s e q u e n c e
                                      function. Further information
                                      i n section "Store            - Recall"
                                      and "Sequence".


      O p t i o n SMG-B1              The i n s t r u m e n t i s f i t t e d w i t h
      Reference O s c i l l a t o r   o p t i o n s a s g i v e n by t h e ad-
                                      hered l a b e l s .
      O p t i o n SMG-B2
      AF S y n t h e s i z e r
      O p t i o n SMG-B3
      X Output


                                      Fuse v a l u e s f o r t h e d i f f e r e n t
                                      AC power s u p p l ies.



                                      F u s e h o l d e r and power s u p p l y
                                      selector.



                                      Power s u p p l y c o n n e c t i o n .
    Label                                   Function

    -@      AM EXT ( X-Axis)                3 cut-outs provided e i t h e r
                                            f o r f i t t i n q t h e corresponding
    -@      FM/@M EXT ( Z - A x i s )       f r o n t panel sockets to t h e
                                            r e a r p a n e l or f o r accommodat-
            AF INT                          i n q t h e s o c k e t s X-Axis a n d
                                            Y-Axis i f t h e X O u t p u t o p t i o n
                                            SMG-B3 is f i t t e d .

                                            Output of t h e i n t e r n a l r e f e r -
                                            e n c e f r e q u e n c y ( l e v e l 0 dBm)
                                            w i t h an i n t e r n a l r e f e r e n c e .
                                            Input of t h e external refer-
                                            e n c e f r e q u e n c y ( l e v e l > I 0 0 mV
                                            s i n e wave or TTL) w i t h a n
                                            external reference.
                                        I   The i n p u t or o u t p u t f r e q u e n c y
                                            c a n be s e l e c t e d a s 5 MHz or
                                        '   1 0 MHz u s i n g a n i n t e r n a l
                                            jumper.
                                            F u r t h e r i n f o r m a t i o n i n sec-
                                            t i o n " I n t e r n a l / E x t e r n a l Ref-
                                            e r e n c e Frequency".


'     fEC 6 2 5          I E E E 488        IEC-bus c o n n e c t o r f o r remote
                                            control.


                                        I   Cut-out provided f o r f i t t i n g
                                        1   t h e f r o n t p a n e l RF o u t p u t t o
                                        1   t h e r e a r panel.


                                            BNC i n p u t f o r p u l s e modula-
                                            t i o n (TTL i n p u t ) .
                                            I f t h e TTL s i g n a l is a t LOW               ':
                                            l e v e l , t h e RF l e v e l i s
                                            blanked.
                                            F o r f u r t h e r i n f o r m a t i o n , see    '



                                            s e c t i o n " M o d u l a t i o n , PMn.
2.2             P r e p a r a t i o n f o r U s-
                                               e



2.2.1           Power S u p p l y F u s e

  he power s u p p l y f u s e is l o c a t e d         i n t h e h o l d e r 2 ( F i g s . 2-2 a n d
2 - 3 ) . The v a l u e o f t h e f u s e f o r        d i f f e r e n t power s u p p l i e s c a n b e
o b t a i n e d f r o m t h e l a b e l 18 ( F i g .   2-2). The f u s e h o l d e r c a n b e r e -
moved by i n s e r t i n g a s c r e w d r i v e r     i n t o t h e cut-out on t h e r i g h t ,




Fig.    2-3     Power s u p p l y p l u g , v o l t a g e selector a n d f u s e h o l d e r



2.2.2           AC P o w e r S u p p l y

The SMG c a n b e u s e d w i t h power s u p p l i e s o f 400 V, 1 2 0 V, 2 2 0 V
a n d 240 V. Check t h a t t h e v o l t a g e s e l e c t o r 1s s e t t o t h e c o r r e c t
s u p p l y b e f o r e u s i n g t h e i n s t r u m e n t . To a d j u s t t o the l o c a l s u p -
p l y , i n s e r t t h e r e q u i r e d f u s e d i n s e r t t h e f u s e h o l d e r a g a i n and
r o t a t e u n t i l t h e v a l u e o f t h e power s u p p l y is a t t h c t o p u n d e r -
n e a t h t h e arrow,

A f u s e t y p e T 2 . 0 D is r e q u i r e d f o r 1 0 0 V a n d 1 2 0 V a n d t y p e
T 1 . 6 D f o r 220 V a n d 240 V.



2.2.3           Rack H o u n t i n g

T h e SMG c a n       be f i t t e d i n t o a n y       19"    rack u s i n g the         19"   adapter
ZZA-93 ( O r 4 .      No. 3 9 6 . 4 8 9 2 . 0 0 ) ,

When f i t t i n q i n t o a r a c k , e n s u r e t h a t the a i r i n l e t t h r o u g h t h e
p e r f o r a t i o n s i n t h e s i d e p a n e l s ?r.d ".he a i r o u t l e t a t t h e r e a r
a r e not i m p e d e d .

F i t t i n q i n s t r u c t i o n s a r e i n c l u d e d w i t h t h e 19" a d a p t t r ,
The s i g n a l g e n e r a t o r SMG o u t p u t s s i q n a l s b e t w e e n 1 0 0   kHz   and
1 0 0 0 MHz a t t h e RF o u t p u t i n a l e v e l r a n q e f r o m 4 3 dBm1         (16 dRm)
t o - 1 4 0 . 4 dBm w i t h AM, PM, F or + M . Two-tone m o d u l a t i o n
                                             M                                          is a l s o
p o s s i b l e a s w e l l a s s i m u l t a n e o u s AM a n d P M o r AM a n d       QM.  The
o u t p u t s i q n a l may b e set a t a f i x e d f r e q u e n c y o r s w e p t ,

A s i q n a l i n t h e f r e q u e n c y r a n a e f r o m 10 Hz t o 1 0 0 kHz w i t h a n am-
p l i t u d e r a n g e f r o m 1 m t o 1 V (Vrms) i s a v a i l a b l e a t t h e AP
                                       V
o u t p u t i f t h e SMG is f i t t e d w i t h t h e o p t i o n AF S y n t h e s i z e r SMG-
B2.

The S G can h e s e t v i a t h e k e y b o a r d ,
     M                                                  r o t a r y k n o b and t h e IEC-bus
interface.




Fig,   2-4     S G front panel
                M
Selecti~nof p a r a m e t e r s

The PAWETER ON/ PF keypad 2 i s u s e d t o s e t t h e p a r a m e t e r f o r
w h i c h n u m e r i c a l e n t r i e s and v a r i a t i o n s t h e n a p p l y . The s e t p a r a -
meter i s i n d i c a t e d by a n LED. O n l y o n e p a r a m e t e r c a n be s e t a t a
t i m e . The o n l y e x c e p t i o n i s t h e STEP p a r a m e t e r which c a n be s e t
a t t h e same time as a n o t h e r p a r a m e t e r ( t o . e n t e r t h e s t e p s i z e f o r
t h e STEP f u n c t i o n ) .

The      SHIFT   parameters          (blue     label)          



◦ Jabse Service Manual Search 2024 ◦ Jabse PravopisonTap.bg ◦ Other service manual resources online : FixyaeServiceinfo