Service Manuals, User Guides, Schematic Diagrams or docs for : . Various Fordlian AGP-ALI

<< Back | Home

Most service manuals and schematics are PDF files, so You will need Adobre Acrobat Reader to view : Acrobat Download Some of the files are DjVu format. Readers and resources available here : DjVu Resources
For the compressed files, most common are zip and rar. Please, extract files with Your favorite compression software ( WinZip, WinRAR ... ) before viewing. If a document has multiple parts, You should download all, before extracting.
Good luck. Repair on Your own risk. Make sure You know what You are doing.




Image preview - the first page of the document
Fordlian AGP-ALI


>> Download Fordlian AGP-ALI documenatation <<

Text preview - extract from the document
Table of Contents

Chapter 1: Introduction                                                         1

        -

Chapter 2

        2.1 Connectors Jumpers ----------------------------------------- 3

        2.2 Install The System CPU Processor------------------------            7

        2. 3 Set CPU Voltage------------------------------------------------    8

        2. 4 Install 586 CPU ---------------------------------------------- 9
        2.4-1 Quick to Setting for BUS Clock 100 MHZ
               frequency CPU-------------------------------------------------   9
        2.4-2 Quick to Setting for INTEL PENTIUM
             MMX/AMD K6 MMX/CYRIX M2 MMX CLK
             &Voltage------------------------------------------------------ 12
        2.4-3 Quick to Setting to INTEL PENTIUM &AMD
             K5 CPU CLK & Voltage----------------------------------- 18
        2.4-4 Quick to Setting for CYRIX 6X86 CPU CLK&
                                                                                20
        Voltage--------------------------------------------------------
        2.5 PCB Layout and Relevant Positions for CLK &
                                                                                21
        Voltage--------------------------------------------------------
        2.6 CPU Multi Ratio & BUS CLK,AGP CLK &PCI
                                                                                22
        CLK------------------------------------------------------------
        2.7 Support 168 pin DIMMX2 &72 pin SIMMX2
            FOR SDRAM/FPM/EDO DRAM------------------------- 23

        2.8 Install DRAM AND SDRAM                                              25
        Memory--------------------

Chapter 3



                                            1
3.1 Main Menu -------------------------------------------------- 26

3.2 Standard CMOS Setup ------------------------------------ 28

3.3 BIOS Features Setup ---------------------------------------   32

3.4 Supervisor/User Password Setting ------------------------ 37

3.5 Setup/Integrated Peripherals Features Setup ------------- 38

3.6 Setup Power Management ---------------------------------- 43

3.7 Setup PnP/PCI Configuration ------------------------------ 47




                               2
Chapter 1                                         INTRODUCTION
This main board is a high performance system hardware based on Intel Pentium
processor and is equipped with three master PCI slots, four 16-bit ISA slot, two
serial ports with 16550 high speed, one parallel with ECP/EPP bi-direction, one
PS/2 Mouse port, one infrared port (IR), dual enhanced PCI IDE ports for 4 IDE
device mode 5 and DMA mode 2, one FDD port. The dimension is 22*25 cm.

Features:
CPU ZIF Socket
   ZIF 321-pin ZIF socket. Socket 7.
   Intel Pentium 90, 100, 120, 133, 150, 166, 180, and 200MHz.
   Intel Pentium-MMX 166/200/233 MHZ
   Switch Voltage Regulator for P55C
   Cyrix M1 P120+/P133+/P150+/P166+/CYRIX M2(MMX)
   AMD K5 /K6 (MMX) CPU

Chipset
 Main board: ALI ALADDIN M1543/M1542 CHIPSET
 Host bus at 60,66,75,83,100MHZ

Memory, SIMM 1-2,DIMMx2
    The RAM MODULE assortment is flexible.
   There are two 168 pin DIMM sockets and two 72 pin SIMM sockets on the
   motherboard.
   You can use 3.3V SDRAM and 5V EDO RAM on the 168 pin DIMM socket
   of the motherboard. The total capacity is up to 256MB.
   Otherwise, you can use 5V EDO RAM and FPM RAM on the 72 pin SIMM
   socket of the motherboard. The total capacity is up to 128MB.
    SIMM RAM MODULE and DIMM RAM MODULE, The total capacity is
    up to 384MB.

Pipe Line Cache
 64 bit Cache.
 Implements level two (L2), external cache write through or write-back
 design, featuring two pipe line sram on board.
 External cache size is on board 512K Cache RAM.
Expansion Slots, ISA1-ISA3,PCI1-PCI3, AGP1


                                      3
 Builds three 16-bit ISA slots and three 32-bit PCI slots (PCI 1 to PCI 3)
 Support one AGP (Accelerated Graphics Port) slot, 66MHZ protocol.

Enhanced PCI IDE & ISA I/O
 Built in enhanced PCI Local Bus IDE controller.
 Ultra DMA/33 Support BUS master IDE
 Supports 4 PCI IDE devices. PIO Mode 5 and DMA Mode 2 and CDROM
 driver. BIOS auto detects HDD.
 Two serial ports with 16550, Infrared port (IR), one Parallel port with
 ECP/EPP pocket device, bi-dirction, one PS/2 mouse port, two FDD.
 Through ECP/EPP, the board increases the performance of printer or
 connect SCSI or IDE devices.
 Controlled by BIOS. Disable I/O function by BIOS in order to Install an
 I/O card. Set COM 1 and COM 2 as COM 3 and COM 4 by BIOS.

System Green BIOS
 Flash BIOS option on board, AWARD deep green BIOS, PLUG & PLAY,
 PnP function.
 Auto configuration for PCI add-on cards.
 I/O Device`s power saving, APM & SMI.
 Implements the EPA Energy Star PC specification with Deep Green system
 design.

          # Full-on : System runs in full speed CPU clock.
          # Doze : System scales-down CPU clock.
          # Standby : System scales-down the CPU clock, and turns off video
                      display, and spin-off hard disk driver.
          # Suspend : With SMM CPU, stop CPU clock in suspend mode.

ACPI (ATX Power Supply Mode)
 power management. Soft-off Control
 Support Modem Ring-in
 RTC Alarm wake up

 Power Connect
 AT/ATX option




                                     4
2.1 Connectors & Jumpers




               5
FRONT1:Power LED, Speaker, SLEEP LED, ATX POWER SWITCH,
       Reset, Hard disk LED, Turbo LED, Turbo Switch.

          Speaker              Sleep      Power
                               LED        LED
         10   9      8 7 6        5 4 3           2 1
         20   19    18 17 16     15 14 13         12 11
              Tubro   Tubro            HDD ATX
         RESET Switch   LED             LED POWER
                                        SWITCH
FRONT1(1-3): Power LED
     PINOUT                             ASSIGNMENTS
       1                                LED OUTPUT
       2                                NC
       3                                GND

FRONT1(4-5): SLEEP LED
     PINOUT                             ASSIGNMENTS
       1                                LED OUTPUT
       2                                HIGH

FRONT1(6): NOT CONNECT

FRONT1(7-10): Speaker Connect
     PINOUT                             ASSIGNMENTS
       1                                speaker output
       2                                GND
       3                                GND
       4                                VCC

FRONT1(11-12): ATX POWER Switch Connect
FRONT1(13-14): Hard Disk LED connect
     PINOUT                       ASSIGNMENTS
       1                          VCC
       2                          LED1 Signal




                                   6
FRONT1(15-16): Turbo LED connect
     PINOUT                           ASSIGNMENTS
       1                              VCC
       2                              LED1 Signal

FRONT1(17-18): Turbo switch connect (Default close)
FRONT1(19-20): RESET switch connect




                                  7
JP1: CPU CLK SELECT.            Please refer section 2-4 relating
JP2: IR connect.
        PINOUT                            ASSIGNMENTS
          1                               VCC
          2                               FIRRX Signal
          3                               IRRX2 Signal
          4                               GND
          5                               IRTX2 Signal

JP3: COMS CLEAR SETTING
       JP3              Function
       1-2              NORMAL
       2-3              CMOS CLEAR

JP5: FOR 168 PIN SDRAM (Synchronous DRAM)
     OR FPM/EDO DRAM Voltage SELECT

        JP5                     Function
      1-2,1-2                   +5V      EDO/FPM
      2-3,2-3                   +3.3V       SDRAM

JP6: FAN +12 POWER

     +12V                 GND

JP7: CPU Voltage Jumper setting. Please refer section 2-3 relating.

JP8: Flash ROM VCC Select

       JP8                Function               REMARK
      1-2 1-2            +12V      VPP           Reserved
      2-3 2-3            +5V       VPP           Factory Default




                                      8
MOUSE1: PS/2 MOUSE CONNECT
     PINOUT                       ASSIGNMENTS
       1                          MDATA
       2                          N.C
       3                          GND
       4                          VCC
       5                          MSCLK

KBCONN1: AT KEYBOARD CONNECT
J1: ATX POWER SUPPLY CONNECT
CN1: AT POWER SUPPLY CONNECT
CN4: Primary IDE CONNECT
CN5: Secondary IDE CONNECT
CN3: Floppy CONNECT
CN2: PRINT CONNECT
COM1: COM1 CONNECT
COM2: COM2 CONNECT
USB-1: USB-1 CONNECT
       PINOUT                ASSIGNMENTS
         1                   VCC
         3                   USBP0-
         5                   USBP0+
         7                   GND_A
         9                   GND_B




USB-2: USB-2 CONNECT
       PINOUT                     ASSIGNMENTS
         2                        VCC
         4                        USBP1-
         6                        USBP1+
         8                        GND_A
        10                        GND_B

SIMM 1-2: 72 pin DRAM Module Socket
DIMM 1-2: 168 pin SDRAM Module Socket


                              9
U11: LM 75 FOR CPU Temperature detect
U10: CPU ZIF SOCKET 7
2.2 Install The System CPU Processor
    Install 586 CPU on the ZIF Socket 7

 Locate the 321-pin ZIF Socket.

 Raise the ZIF Socket retaining arm to the open position. Pin Coordinates
 A-1 will be the arm corner.

 Position the notched corner of microprocessor over the notched corner of
 the ZIF Socket and align the pins of CPU over the Socket.

 Carefully insert the aligned CPU into the ZIF Socket and press Firmly.
 After CPU inserted, press ZIF retaining arm downwards.

 Examine the installed CPU to ensure it is install in the correct direction and
 pin aligned properly.




                                      10
JP7:   SET CPU VOLTAGE


  CPU POWER                          CPU POWER
    MODE    JP7     EXAMPLE            MODE         JP7     EXAMPLE

   ONLY 3.52V        AMD-K5              DUAL               FOR
                    CYRIX M1          2.7V & 3.3V         FUTURE CPU

   ONLY 3.4V        FOR                  DUAL               FOR
                  FUTURE CPU          2.6V & 3.3V         FUTURE CPU

   ONLY 3.3V         INTEL               DUAL               FOR
                    PENTIUM           2.5V & 3.3V         FUTURE CPU

  DUAL 3.2V &       AMD K6              DUAL                AMD K6-3
                                     2.4V&3.3V
     3.3V          PR-233 MHZ                               400/500

  DUAL 3.1V &        FOR                DUAL               FOR
                                     2.3V & 3.3V
     3.3V         FUTURE CPU                              FUTURE CPU
                                 DUAL 2.2V&3.3V
  DUAL 3.0V &       FOR                                     AMD-K6
                                 DUAL 2.2V&3.45V
     3.3V         FUTURE CPU                               266 /300MHZ

  DUAL 2.9V &      IBM 6X86MX          DUAL                 FOR
     3.3V            AMD -K6         2.1V & 3.3V          FUTURE CPU
                    CYRIX M2
     DUAL           IBM 6X86L          DUAL                 FOR
   2.8V & 3.3V        INTEL           2.0V & 3.3V         FUTURE CPU
                  PENTIUM MMX




                                11
INSTALL 586 CPU
2.4-1 QUICK TO SETTING FOR BUS CLOCK 100HZ FREQUENCY
CPU
A: AMD-K6-2
(1) CPU CLK

Product Name   CPU Speed    BUS CLK        JP1        Multiplier
               (MHZ)       (MHZ)

                                      1          2

AMD-K6-         200(MHZ)    100       3          4
PR200                                 5          6      2X

                                      7          8

                                      9          10

                                      11         12


                                      1          2

AMD-K6-PR25      250         100      3          4      2.5X
0                                     5          6

                                      7          8

                                      9          10

                                      11         12


                                      1          2

AMD-K6-PR30     300         100       3          4       3X
0
                                      5          6

                                      7          8

                                      9          10

                                      11         12




                              12
Product Name   CPU Speed   BUS CLK        JP1   Multiplier
               (MHZ)       (MHZ)
                                     1     2


AMD-K6-PR35     350         100      3     4       3.5X
0
                                     5     6

                                     7     8

                                     9     10

                                     11    12

                                     1     2


AMD-K6-PR40     400         100      3     4       4X
0
                                     5     6

                                     7     8

                                     9     10

                                     11    12

                                     1     2


AMD-K6-PR45     450         100      3     4       4.5X
0
                                     5     6

                                     7     8

                                     9     10

                                     11    12




                             13
  Product Name   CPU Speed      BUS CLK                JP1         Multiplier
                                 (MHZ)
                                                 1        2


  AMD-K6-             500       100              3        4           5X
  PR500
                                                 5        6

                                                 7        8

                                                 9        10

                                                 11       12

                                                 1        2

  AMD-K6-             550       100              3        4           5.5X
  PR550
                                                 5        6


                                                 7        8


                                                 9        10


                                                 11       12


(2) SET CPU Voltage

  CPU POWER                                JP7
  TYPE/JUMPER
  DUAL 2.2V & 3.3V
         OR                     7         5           3        1
  DUAL 2.2V & 3.45V             8         6           4        2


In case the marking voltage on CPU is not meet up with our manual,
Please setup according to CPU marking, You can reference our manual
section 2-3: the jumper setting of CPU Voltage.
For better reliability,we suggest Using PC-100 SDRAM for 100MHZ CPU.



                                14
AMD K6-III
(1) CPU CLK


PRODUCT CPU SPEED     BUS           MULTIPLIER
 NAME         MHZ     MHZ     JP1


AMDK6-III     400      100              4X
   400



AMDK6-III     450      100             4.5X
   450



AMDK6-III     475      95               5X
   475



AMDK6-III     500      100              5X
   500



(2)SET CPU VOLTAGE


  CPU POWER
 TYPE / JUMPER       JP7



DUAL 2.4V&3.3V




                             15
B: CYRIX-M2
(1) CPU CLK

Product Name     CPU Speed   BUS         JP1        Multiplier


                                    1          2

                                    3          4
Cyrix-M2-PR233     200       100                      2X
                                    5          6

                                    7          8

                                    9          10

                                    11         12



                                    1          2

CYRIX-M2-PR333     250        100   3          4       2.5X

                                    5          6


                                    7          8

                                    9          10

                                    11         12


                                    1          2

CYRIX-M2-PR350    300         100   3          4        3X

                                    5          6

                                    7          8


                                    9          10

                                    11         12




                             16
(2) SET CPU VOLTAGE

    CPU POWER                              JP7
    TYPE/JUMPER


                                 7        5         3        1
    DUAL 2.9V & 3.3V             8        6         4        2




In case the marking voltage on CPU is not meet up with our manual,
Please setup according to CPU marking,
You can reference our manual section 2-3: the jumper setting of CPU
Voltage.

For better reliability,we suggest Using PC-100 SDRAM for 100MHZ CPU.




                                     17
2.4-2 QUICK TO SETTING FOR INTEL PENTIUM MMX /AMD K6
MMX /CYRIX M2 MMX CLK & VOLTAGE
A/ INTEL PENTIUM MMX
(1) CPU CLK

Product Name   CPU Speed   BUS CLK         JP1        Multiplier

                                      1          2


                                      3          4

                                      5          6
PENTIUM         166        66                         2.5x
MMX-166
                                      7          8

                                      9          10


                                      11         12

                                      1          2

                                      3          4

PENTIUM-M                             5          6
MX-200           200        66                         3X
                                      7          8

                                      9          10

                                      11         12


                                      1          2

                                      3          4

                                      5          6
PENTIUM-M       233        66
MX- 233                                                3.5X
                                      7          8

                                      9          10


                                      11         12


                                 18
CPU POWER                       JP7
TYPE/JUMPER


DUAL 2.8V & 3.3V   7        5    3    1
                   8        6    4    2




                       19
AMD K6 MMX

(1) CPU CLK

  Product Name   CPU Speed   BUS CLK        JP1        Multiplier


                                       1          2


                                       3          4

                                       5          6
  AMD K6-166      166        66                        2.5X

                                       7          8

                                       9          10


                                       11         12

                                       1          2

                                       3          4

                                       5          6
  AMD K6-200      200         66                        3X
                                       7          8

                                       9          10

                                       11         12


                                       1          2

                                       3          4

                                       5          6
  AMD K6- 233    233         66                        3.5X
                                       7          8


                                       9          10


                                       11         12


                               20
Product Name   CPU Speed   BUS CLK           JP1        Multiplier

                                     1             2

                                     3             4

                                     5             6
AMD K6-266       266         66                          4X
                                     7             8

                                     9             10

                                     11            12


                                     1             2

                                     3             4

                                     5             6
AMD K6- 300     300         66                          4.5X
                                     7             8

                                     9             10

                                     11            12
                                     1             2

                                         1
                                     3             4

                                         3
AMD K6-333      333          66      5             6     5X
                                         5
                                     7             8
                                         7
                                     9             10
                                      9
                                     11            12

                                         11
                                     1             2
                                         1
                                     3             4
                                         3
                                     5             6
AMD K6- 333    333          95           5              3.5X
                                     7             8
                                         7
                                     9             10

                                     11            12

                             21
Product Name   CPU Speed   BUS CLK        JP1        Multiplier

                                     1          2

                                     3          4

                                     5          6
AMD K6-366       366            66                    5.5X
                                     7          8

                                     9          10

                                     11         12


                                     1          2

                                     3          4

                                     5          6
AMD K6- 380     380         95                       4X
                                     7          8

                                     9          10

                                     11         12




                           22
SET CPU VOLTAGE


 CPU TYPE         CPU POWER                  JP7
                  TYPE /JUMPER




AMD-K6-166/200    DUAL 2.9V & 3.3V   7    5         3   1
                                     8    6         4   2




                                     7    5         3   1
AMD-K6-233 /266   DUAL 3.2V & 3.3V   8    6         4   2




                                     7   5         3     1
AMD-K6-266/300    DUAL 2.2V &3.3V
                                     8   6         4     2
AMD-K6-333        DUAL 2.2V &3.45V




                              23
In case the marking voltage on CPU is not meet up with our manual,
Please setup according to CPU marking,
You can reference our manual section 2-3: the jumper setting of CPU
Voltage.
Only use ICS9148B-36 freqency Generator can be support bus CLK 95
MHZ.
For better reliability,we suggest Using PC-100 SDRAM for 100MHZ CPU.




                                24
CYRIX M2 MMX
(1) CPU CLK


  Product Name     CPU Speed    BUS CLK        JP1        Multiplier
                   (MHZ)        (MHZ)

                                          1          2

                                          3          4
  Cyrix-M2-PR166     150            60                      2.5X
                                          5          6

                                          7          8

                                          9          10

                                          11         12



                                          1          2

  CYRIX-M2-PR166     133            66    3          4      2X

                                          5          6


                                          7          8

                                          9          10

                                          11         12


                                          1          2

  CYRIX-M2-PR200    166             66    3          4      2.5X

                                          5          6

                                          7          8


                                          9          10

                                          11         12



                               25
Product Name     CPU Speed   BUS CLK        JP1        Multipli
                 (MHZ)       (MHZ)                     er

                                       1          2

                                       3          4
Cyrix-M2-PR200     150        75                         2X
                                       5          6

                                       7          8

                                       9          10

                                       11         12


                                       1          2

                                       3          4
CYRIX-M2-PR233     188            75                    2.5X
                                       5          6

                                       1          2
                                       7          8

                                       3          4
                                       9          10

                                       5          6
                                       11         12



                                       1          2

CYRIX-M2-PR233    166             83   3          4      2X

                                       5          6


                                       7          8

                                       9          10

                                       11         12




                             26
Product Name     CPU Speed   BUS CLK        JP1        Multiplier
                  (MHZ)       (MHZ)

                                       1          2

                                       3          4
Cyrix-M2-PR266     208       83                          2.5X
                                       5          6

                                       7          8

                                       9          10

                                       11         12


                                       1          2

                                       3          4
CYRIX-M2-PR300     233        66                          3.5X
                                       5          6


                                       7          8

                                       9          10

                                       11         12



                                       1          2

CYRIX-M2-PR300    225         75       3          4        3X

                                       5          6


                                       7          8

                                       9          10

                                       11         12




                             27
Product Name     CPU Speed   BUS CLK        JP1   Multiplier

                                       1    2


                                       3    4
Cyrix-M2-PR333     250       83                     3X
                                       5    6

                                       7    8

                                       9    10

                                       11   12


                                       1    2

                                       3    4
CYRIX-M2-PR333     263        75                     3.5X
                                       5    6


                                       7    8

                                       9    10

                                       11   12



                                       1    2

CYRIX-M2-PR350    291         83       3    4         3.5X

                                       5    6


                                       7    8

                                       9    10

                                       11   12




                              28
  Product Name       CPU Speed     BUS CLK              JP1             Multiplier

                                               1        2


  CYRIX-M2-PR350       300             75      3        4                   4X

                                               5        6


                                               7        8

                                               9        10

                                               11       12



(2) SET CPU VOLTAGE

     CPU TYPE             CPU Power                           JP7
                          Type/Jumper

  IBM-6X86MX
  /PR166/PR200          DUAL 2.9V & 3.3V            7       5       3      1
  /PR233/PR266                                      8       6       4      2
  /PR300/PR333




In case the marking voltage on CPU is not meet up with our manual,
Please setup according to CPU marking,
You can reference our manual section 2-3: the jumper setting of CPU
Voltage.




                                  29
2-4-3 QUICK TO SETTING FOR INTEL PENTIUM & AMD K5 CPU
CLK & VOLTAGE

 Product Name   CPU Speed   BUS CLK         JP1   Multiplie

                                       1     2


                                       3     4

                                       5     6
 PENTIUM -90     90          60                   1.5x
 AMD K5-PR90
                                       7     8
 AMD
 K5-PR120                              9     10


                                       11    12

                                       1     2

                                       3     4

 PENTIUM-100                           5     6
 AMD             100          66                   1.5X
 K5-PR100                              7     8
 AMD
                                       9     10
 K5-PR133
                                       11    12


                                       1     2

                                       3     4

                                       5     6
 PENTIUM-120    120          60
 AMD                                   7     8     2X
 K5-PR150
                                       9     10


                                       11    12




                                  30
Product Name   CPU Speed   BUS CLK        JP1   Multiplie

                                     1     2


                                     3     4

                                     5     6
PENTIUM         133         66                  2x
-133
                                     7     8

                                     9     10


                                     11    12

                                     1     2

                                     3     4

                                     5     6
PENTIUM-150    150              60               2.5X
                                     7     8

                                     9     10

                                     11    12


                                     1     2

                                     3     4

                                     5     6
PENTIUM-166    166          66
AMD                                  7     8     2.5X
K5-PR166
                                     9     10


                                     11    12




                           31
Product Name    CPU Speed   BUS CLK                JP1       Multiplie

                                          1         2


                                          3         4

                                          5         6
PENTIUM           180        60                              3X
-180
                                          7         8

                                          9         10


                                          11        12

                                          1         2

                                          3         4

                                          5         6
PENTIUM-200       200         66                              3X
                                          7         8

                                          9         10

                                          11        12




PENTIUM        ONLY 3.3V
90-200                                7        5         3    1
                                      8        6         4    2


AMD-K5
                                      7        5         3    1
PR90-PR166     ONLY 3.52V
                                      8        6         4    2




                              32
2.4-4 QUICK TO SETTING FOR CYRIX 6X86 CPU CLK & VOLTAGE

   Product Name   CPU Speed   BUS CLK        JP1   Multiplie

                                        1     2


                                        3     4

                                        5     6
   6X86-P150-GP    120         60                  2X

                                        7     8

                                        9     10


                                        11    12

                                        1     2

                                        3     4

                                        5     6
   6X86-P166-GP   133          66                   2X
                                        7     8

                                        9     10

                                        11    12


                                        1     2

                                        3     4

                                        5     6
   6X86-P200-GP   150          75
                                        7     8     2X


                                        9     10


                                        11    12




                                33
SET CPU VOLTAGE

          CPU Power                 JP7
          Type/Jumper

        ONLY 3.52V
                               7   5      3   1
                               8   6      4   2



        ONLY 3.3V
                              7     5     3   1
                              8     6     4   2



                              7     5     3   1
       ONLY 2.8V &3.3V
                              8     6     4   2




                         34
CYRIX M2 MMX
CPU CLK
Product Name
 Product Name   CPU Speed
                CPU Speed    BUS CLK
                            BUS CLK     JP1   JP1   Multiplier
                                                         Multiplie

                                         1     2


                                         3     4

                                         5     6
 CYRIX-M2-PR     150(MHZ)    60                          2.5x
 166
                                         7     8

                                         9     10


                                         11    12

                                         1     2

                                         3     4

 CYRIX-M2-PR                             5     6
 166             133          66                          2X
                                         7     8

                                         9     10

                                         11    12


                                         1     2

                                         3     4

 CYRIX-M2-PR                             5     6
 200             166         66
                                                          2.5X
                                         7     8


                                         9     10


                                         11    12




                                   35
Product Name   CPU Speed   BUS CLK        JP1   Multiplie

                                     1     2


                                     3     4

                                     5     6
CYRIX-M2-PR     150         75                  2x
200
                                     7     8

                                     9     10


                                     11    12

                                     1     2

                                     3     4

CYRIX-M2-PR                          5     6
233            188           75                  2.5X
                                     7     8

                                     9     10

                                     11    12


                                     1     2

                                     3     4

CYRIX-M2-PR                          5     6
233            166          83
                                     7     8     2X


                                     9     10


                                     11    12




                              36
Product Name   CPU Speed   BUS CLK        JP1   Multiplie

                                     1     2


                                     3     4

                                     5     6
CYRIX-M2-PR     208         83                  2.5x
266
                                     7     8

                                     9     10


                                     11    12

                                     1     2

                                     3     4

CYRIX-M2-PR                          5     6
300            233           66                  3.5X
                                     7     8

                                     9     10

                                     11    12


                                     1     2

                                     3     4

CYRIX-M2-PR                          5     6
300            225          75
                                     7     8     3X


                                     9     10


                                     11    12



                            37
Product Name   CPU Speed   BUS CLK        JP1   Multiplie

                                     1     2


                                     3     4

                                     5     6
CYRIX-M2-PR     250         83                  3x
333
                                     7     8

                                     9     10


                                     11    12

                                     1     2

                                     3     4

CYRIX-M2-PR                          5     6
333            263           75                  3.5X
                                     7     8

                                     9     10

                                     11    12


                                     1     2

                                     3     4

CYRIX-M2-PR                          5     6
350            291          83
                                     7     8     3.5X


                                     9     10


                                     11    12




                              38
Product Name   CPU Speed        BUS CLK            JP1            Multiplie

                                              1        2

                                              3        4

CYRIX-M2-PR                                   5        6
350                300              75
                                              7        8           4X


                                              9        10


                                              11       12




 SET CPU VOLTAGE

CPU POWER                CPU TYPE                           JP7
TYPE/JUMPER
DUAL 2.9V & 3.3V         IBM-6X86MXPR16
                         6/PR200/PR233    7        5          3         1
                         PR266            8        6          4         2
                         PR300/PR333




                                     39
 2.8 Install DRAM AND SDRM Memory

The Board supports different types 72-pin SIMM and DIMM whatever single
side or double side. There is no jumper nor connector needed for memory
configuration. The RAM MODULE assortments is flexible. There are two 168
pin DIMM sockets and two 72 pin SIMM sockets on the motherboard.
You can use 3.3V SDRAM and 5V EDO RAM on the 168 pin DIMM socket of
the motherboard. The total capacity is up to 256MB. Otherwise, you can use 5V
EDO RAM and FPM RAM on the 72 pin SIMM socket of the motherboard. The
total capacity is up to 128MB. SIMM RAM MODULE and DIMM RAM
MODULE, The total capacity is up to 384MB.

It also supports both fast page DRAM or EDO DRAM SIMM, but can't use
them at same bank, i.e. one SIMM is fast page DRAM and the other is EDO
SIMM.

SIMM can be use parity (x36) or none parity (x32). The 70ns fast page SIMM
or 60ns EDO DRAM needed, at least.

Example:
 BANK 0&1, DIMM         BANK 2&3, DIMM2       BANK 4&5, SIMM1,2      TOTAL
        8MB                   NONE                   NONE              8MB
       NONE                    8MB                   NONE              8MB
       NONE                   NONE                    8MB              8MB
        8MB                    8MB                   NONE             16MB
       NONE                    8MB                    8MB             16MB
        8MB                   NONE                    8MB             16MB
        8MB                    8MB                    8MB             24MB
       16MB                   16MB                   NONE             32MB
       32MB                   NONE                   32MB             64MB
       32MB                   32MB                   NONE             64MB
       64MB                   64MB                   NONE             128MB
       128MB                  128MB                  NONE             256MB
       128MB                  128MB                  128MB            384MB




                                     40
Chapter 3                                                           BIOS SETUP

3.1 Main Menu

Once you enter the Award BIOS CMOS Setup Utility, the Main Menu will
appear on the screen. The Main Menu allows you to select from several
setup functions and two exit choices. Use the arrow keys to select among the
items and press  to accept and enter the sub-menu.

                       ROM PCI/ISA BIOS (2A5KFF9A)
                          CMOS SETUP UTILITY
                         AWARD SOFTWARE, INC.
  STANDARD CMOS SETUP                          INTEGRATED PERIPHERALS
  BIOS FEATURES SETUP                          SUPERVISOR PASSWORD
  CHIPSET FEATURES SETUP                       USER PASSWORD
  POWER MANAGEMENT SETUP                       IDE HDD AUTO DETECTION
  PNP/PCI CONFIGURATION SETUP                  HDD LOW LEVEL FORMAT
  LOAD BIOS DEFAULTS                           SAVE & EXIT SETUP
  LOAD SETUP DEFAULTS                          EXIT WITHOUT SAVING
  Esc : Quit                                    : Select Item
  F10 : Save & Exit Setup                      (Shift) F2 : Color
                            Time, Date,    Hard Disk Type...


Note that a brief description of each highlighted selection appears at the
bottom of the screen.

Setup Items
The main menu includes the following main setup categories. Recall that
some systems may not include all entries.

Standard CMOS Setup
This setup page includes all the items in a standard, AT-compatible BIOS.

BIOS Features
This setup page includes all the items of Award special enhanced features.

Super/User Password Setting
Change, set, or disable password. It allows you to limit access to the system
and Setup, or just to Setup.

Chipset Features Setup
                                          39
This setup page includes all the items of chipset special features.

Power Management Setup
This entry only appears if your system supports Power Management, "Green
PC", standards.

PNP/PCI Configuration Setup
This entry appears if your system supports PNP/PCI.

Load BIOS Defaults
The BIOS defaults have been set by the manufacturer and represent settings
which provide the minimum requirements for your system to operate.

Load Setup Defaults
The chipset defaults are settings which provide for maximum system
performance. While Award has designed the custom BIOS to maximize
performance, the manufacturer has the right to change these defaults to meet
their needs.

Integrated Peripherals
This section page includes all the items of IDE hard drive and Programmed
Input/ Output features.

IDE HDD Auto Detection
Automatically detect and configure hard disk parameters. The Award BIOS
includes this ability in the event you are uncertain of your hard disk's
parameters.

HDD Low Level Format
If supported by your system, this provides a hard disk low level format utility.
Save & Exit Setup
Save CMOS value changes to CMOS and exit setup.
Exit Without Save
Abandon all CMOS value changes and exit setup.




3.2 Standard CMOS Setup

                                       40
The items in Standard CMOS Setup Menu are divided into 10 categories.
Each category includes no, one or more than one setup items. Use the arrow
keys to highlight the item and then use the  or  keys to select
the value you want in each item.

                           ROM PCI/ISA BIOS (2A5KKF9A)
                             STANDARD CMOS SETUP
                             AWARD SOFTWARE. INC.
Date (mm:dd:yy) : Fri, Dec 6 1996
Time (hh:mm:ss) : 15 : 40 : 00
HARD DISKS         TYPE SIZE CYLS HEAD PRECOMP LANDE SECTOR MODE
Primary Master       : Auto      0       0         0     0         0         0    AUTO
Primary Slave        : Auto      0       0         0     0         0         0    AUTO
Secondary Master     : Auto      0       0         0     0         0         0    AUTO
Secondary Slave      : Auto      0       0         0     0         0         0    AUTO


Drive A            : 1.44M, 3.5in
Drive B            : None
                                                           Base Memory :    640K
                                                       Extended Memory : 15360 K
Video              : EGA/VGA                              Other Memory :    384K
Halt On            : All ,But Keyboard                     Total Memory : 16384K
 ESC      : Quit        : Select Item                        PU/PD/+/- : Modify
 F1       : Help       (Shift) F2 : Change Color
Date
The date format is ,   . Press to show the
calendar.
  day       The day, from Sun to Sat, determined by the BIOS and is
           display-only
  date      The date, from 1 to 31 (or the maximum allowed in the month)
  month The month, Jan through Dec.
  year      The year, from 1900 through 2099
Time
The time format is . The time is calculated based on
the 24-hour military-time clock. For example, 1 p.m. is 13:00:00
Daylight saving
The category adds one hour to the clock when daylight-saving time begins.
It also subtracts one hour when standard time returns.

 Enabled           Enabled daylight-saving
 Disabled          Disabled daylight-saving
                                              41
Primary Master/ Primary Slave/Secondary Master/
Secondary Slave
The categories identify the types of 2 channels that have been installed in the
computer. There are 45 predefined types and 4 user definable types are for
Enhanced IDE BIOS. Type 1 to Type 45 are predefined. Type user is user-
definable.
Press PgUp or PgDn to select a numbered hard disk type or type the number
and press . Note that the specifications of your drive must match with
the drive table. The hard disk will not work properly if you enter improper
information for this category. If your hard disk drive type is not matched or
listed, you can use Type "User" to define your own drive type manually.
If you select Type "User', you will need to know the information listed
below. Enter the information directly from the keyboard and press .
This information should be included in the documentation from your hard
disk vendor or the system manufacturer.
If the controller of HDD interface is ESDI, the selection shall be "Type 1".
If the controller of HDD interface is SCSI, the selection shall be "None".
If you select Type "Auto", BIOS will Auto-Detect the HDD & CD-ROM
Drive at the POST stage and showing the IDE for HDD & CD-ROM Drive.

 TYPE                drive type
 CYLS.               number of cylinders
 HEADS               number of heads
 PRECOMP             write precom
 LANDZONE            landing zone
 SECTORS             number of sectors
 MODE                mode type
If a hard disk has not been installed select NONE and press .
Drive A Type/ Drive B Type
The category identifies the types of floppy disk drive A or drive B that have
been installed in the computer.
None            No floppy drive installed
360K, 5.25 in 5-1/4 inch PC-type standard drive; 360 kilobyte capacity
1.2M, 5.25 in 5-1/4 inch AT-type high-density drive; 1.2 megabyte capacity
720M, 3.5 in 3-1/2 inch double-sided drive; 720 kilobyte capacity
1.44M, 3.5 in 3-1/2 inch double-sided drive; 1.44 megabyte capacity
2.88M, 3.5 in 3-1/2 inch double-sided drive; 2.88 megabyte capacity




                                       42
Video
The category selects the type of video adapter used for the primary system
monitor. Although secondary monitors are supported, you do not have to
select the type in Setup.
EGA/VGA         Enhanced Graphics Adapter/Video Graphics Array, For
                EGA, VGA, SEGA, SVGA, or PGA monitor adapters.
CGA 40          Color Graphics Adapter, power up in 40 column mode
CGA 80          Color Graphics Adapter, power up in 80 column mode
MONO            Monochrome adapter, includes high resolution monochrome
                adapters
Error Halt
The category determines whether the computer will stop if an error is
detected during power up.
No errors          Whenever the BIOS detects a non-fatal error the system
                   will be stopped and you will be prompted.
All errors         The system boot will not be stopped for any error that
                   may be detected.
All,               The system boot will not stop for a keyboard error, it
But Keyboard       will stop for all other errors.
All, But Diskette The system boot will not stop for a disk error; it will
                   stop for all other errors.
All, But Disk/Key The system boot will not stop for a keyboard or disk
                   error; it will stop for all other errors.
Memory
The category is display-only which is determined by POST (Power on Self
Test)
of the BIOS.
Base Memory
The POST will determine the amount of base (or conventional) memory
installed in the system. The value of the base memory is typically 512K for
systems with 512K memory installed on the motherboard, or 640K for
system with 640K or more memory installed on the motherboard.
Extended Memory
The BIOS determines how much extended memory is present during the
POST. This is the amount of memory located above IMB in the CPU'S
memory address map.
Other Memory
This refers to the memory located in the 640K to 1024K address space. This
is memory that can be used for different applications. DOS uses this area to
load device drivers in an effort to keep as much base memory free for
application programs. The BIOS is the most frequent user of this RAM area
                                      43
since this is where it shadows RAM.

3.3 BIOS Features Setup

This section allows you to configure your system for basic operation. You
have the opportunity to select the system`s default speed, boot-up sequence,
keyboard operation, shadowing and security.
                     ROM PCI/ISA BIOS (2A5KKF9A)
                          BIOS FEATURES SETUP
                         AWARD SOFTWARE. INC.
Virus Warning                : Disabled     Video BIOS Shadow       : Enabled
CPU Internal Cache           : Enabled      C8000-CBFFF Shadow      : Disabled
External Cache               : Enabled      CC000-CFFFF Shadow      : Disabled
Quick Power On Self Test     : Enabled      D0000-D3FFF Shadow      : Disabled
Boot Sequence                : C, A, SCSI   D4000-D7FFF Shadow      : Disabled
Swap Floppy Drive            : Disabled     D8000-DBFFF Shadow      : Disabled
Boot Up Floppy Seek          : Enabled      DC000-DFFFF Shadow      : Disabled
Boot Up Numlock Status       : On
Boot Up System Speed         : High
Gate A20 Option              : Fast
Typematic Rate Setting       : Disabled
Typematic Rate (Chars/Sec)   :6
Typematic Delay (Msec)       : 250
Security Option              : Setup        ESC : Quit                : Select Item
PCI/VGA Palett Snoop         : Disabled     F1 : Help                PU/PD/+/- : Modify
Assign IRQ For VGA           : Enabled      F5 : Old Values          (Shift) F2 : Color
OS Select For DRAM >64MB     : Non-OS2      F6 : Load BIOS Defaults
Report No FDD For WIN 95     : No           F7 : Load Setup Defaults
Virus Warning
When this item is enabled, the Award BIOS will monitor the boot sector and
partition table of the hard disk drive for any attempt at modification. If an
attempt is made, the BIOS will halt the system and the following error
message will appear. Afterwards, if necessary, you will be able to run an
antivirus program to locate and remove the problem before any damage is
done.




                                  !WARNING!
                        Disk boot sector is to be modified
                  Type "Y" to accept write or "N" to abort write

                                            44
                            Award Software, Inc.
Enabled          Activates automatically when the system boots up causing a
                 warning message to appear when anything attempts to access
                 the boot sector or hard disk partition table.
Disabled         No warning message will appear when anything attempts to
                 access the boot sector or hard disk partition table.

NOTE:
Many disk diagnostic programs which attempt to access the boot sector table
can cause the above warning message. If you will be running such a program,
we recommend that you first disable Virus Protection before band.

CPU Internal Cache/External Cache
These two categories speed up memory access. However, it depends on
CPU/chipset design. The default value is enable.
Enabled            Enabled cache
Disabled           Disable cache

Quick Power On Self Test
This category speeds up Power On Self Test (POST) after you power up the
computer. If it is set to Enable, BIOS will shorten or skip some check items
during POST.
Enabled               Enable quick POST
Disabled              Normal POST

Boot Sequence
The category determines which drive to search first for the disk operating
system (i.e., DOS). Default value is A, C.
C,A                 System will first search for hard disk drive then floppy disk
                    drive.
A,C                 System will first search for floppy disk drive then hard disk
                    drive.
CDROM, C,A          System will first search for CDROM drive, then hard disk
                    drive and then floppy disk drive.
C, CDROM, A         System will first search for hard disk drive, then CDROM
                    drive, and then floppy disk drive.

Swap Floppy Drive
This item allows you to determine whether enable the swap floppy drive or
not.

                                      45
The choice: Enabled/Disabled.


Boot Up Floppy Seek
During POST, BIOS will determine if the floppy disk drive installed is 40 or
80tracks. 360K type is 40 tracks while 760K, 1.2M and 1.44M are all 80
tracks.
Enabled        BIOS searches for floppy disk drive to determine if it is 40 or
               80 tracks. Note that BIOS can not tell from 720K, 1.2M or
               1.44M drive type as they are all 80 tracks.
Disabled       BIOS will not search for the type of floppy disk drive by track
               number. Note that there will not be any warning message if the
               drive installed is 360K.
Boot Up NumLock Status
This allows you to determine the default state of the numeric keypad. By
default, the system boots up with NumLock on.
On               Keypad is number keys
Off              Keypad is arrow keys
Boot Up System Speed
Selects the default system speed- the normal operating speed at power up.
High            Set the speed to high
Low             Set the speed to low
Gate A20 Option
This entry allows you to select how the gate A20 is handled. The gate A20 is a
device used to address memory above 1 Mbytes. Initially, the gate A20 was
handled via a pin on the keyboard. Today, while keyboards still provide this
support, it is more common, and much faster, for the system chipset to provide
support for gate A20.
Normal           keyboard
Fast             chipset
Typematic Rate Setting
This determines if the typematic rate is to be used. When disabled, continually
holding down a key on your keyboard will generate only one instance. In other
words, the BIOS will only report that the key is down.
When the typematic rate is enabled, the BIOS will report as before, but it will
then wait a moment, and , if the key is still down, it will begin the report that
the key has been depressed repeatedly. For example, you would use such a
feature to accelerate cursor movements with the arrow keys.
Enabled          Enabled typematic rate
Disabled         Disable typematic rate

                                       46
Typematic Rate (Chars/Sec)
When the typematic rate is enabled, this selection allows you select the rate at
which the keys are accelerated.

 6             6 characters per second
 8             8 characters per second
 10            10 characters per second
 12            12 characters per second
 15            15 characters per second
 20            20 characters per second
 24            24 characters per second
 30            30 characters per second

Typematic Delay (Msec)
When the typematic rate is enabled, this selection allows you to select the
delay between when the key was first depressed and when the acceleration
begins.

 250           250 msec
 500           500 msec
 750           750 msec
 1000          1000 msec

Security Option
This category allows you to limit access to the system and Setup, or just to
Setup.
System         The system will not boot and access to Setup will be denied if
               the correct password is not entered at the prompt.
Setup          The system will boot, but access to Setup will be denied if the
               correct password is not entered at the prompt.

Note: To disable security, select PASSWORD SETTING at Main Menu and
then you will be asked to enter password. Do not type anything and just press
, it will disable security. Once the security is disabled, the system will
boot and you can enter Setup freely.


                                       47
OS Select for DRAM > 64
This item allows you to access the memory that over 64MB in OS/2.

The choice: Non-OS2, OS2.


PCI/ VGA Palette Snoop
It determines whether the MPEG ISA/VESA VGA Cards can work with
PCI/VGA or not.

Enabled     When PCI/VGA working with MPEG ISA/VESA VGA Card.
Disabled    When PCI/VGA not working with MPEG ISA/VESA VGA Card.

Video BIOS Shadow
Determines whether video BIOS will be copied to RAM. However, it is
optional depending on chipset design. Video Shadow will increase the video
speed.
Enabled      Video shadow is enabled
Disabled     Video shadow is disabled

C8000-CBFFF Shadow/DC000-DFFFF Shadow
These categories determine whether option ROMs will be copied to RAM.
An example of such option ROM would be support of on-board SCSI.
Enabled     Optional shadow is enabled
Disabled    Optional shadow is Disabled




                                     48
3.4 Supervisor/User Password Setting

You can set either supervisor or user password, or both of them. The
differences between them are:

supervisor password: can enter and change the options of the setup menus.
user password: just can enter but do not have the right to change the options of
the setup menus.

When you select this function, the following message will appear at the center
of the screen to assist you in creating a password.

                          ENTER PASSWORD:

Type the password, up to eight characters in length, and press . The
password typed now will clear any previously entered password from CMOS
memory. You will be asked to confirm the password. Type the password again
and press . You may also press  to abort the selection and not
enter a password.

To disable a password, just press  when you are prompted to enter the
password. A message will confirm the password will be disabled. Once the
password is disabled, the system will boot and you can enter Setup freely.

                         PASSWORD DISABLED.

When a password has been enabled, you will be prompted to enter it every
time
you try to enter Setup. This prevents an unauthorized person from changing
any part of your system configuration.

Additionally, when a password is enabled, you can also require the BIOS to
request a password every time your system is rebooted. This would prevent
unauthorized use of your computer.


                                       49
You determine when the password is required within the BIOS Features Setup
Menu and its Security option (see Section 4). If the Security option is set to
"System", the password will be required both at boot and at entry to Setup. If
set to "Setup", prompting only occurs when trying to enter Setup.]




3.5 Setup/Integrated Peripherals Features Setup
                            ROM PCI/ISA BIOS (2A5KKF9A)
                             CHIPSET FEATURES SETUP
                              AWARD SOFTWARE. INC.
Auto Configuration          : Enabled CPU Warning Temperature              : 60C/133F
L2 TAG RAM Size             :8         Current CPU Temperature              : 51C/123F
AT Bus Clock                : CLK2/4 Shutdown Temperature                  : 75C/167F
DRAM Timing                 : Normal
SDRAM CAS Latency           :3
Pipelined Function          : Enabled
Graphics Aperture Size      : 64MB
SDRAM Burst X-1-1-1-1-1-1-1 : Disabled
DRAM Data Integrity Mode    : Disabled
Memory Hole At 15-16M       : Disabled
Host Read DRAM Command : Bypass
AGP Read Burst              : Enabled
ISA Line Buffer             : Enabled
Passive Release             : Disabled
Delay Transaction           : Disabled
Primary Frame Buffer        : Disabled
VGA Frame buffer            : Disabled
Data Merge                  : Disabled
IO Recovery Period          : 2US


                                            Quit                     :Select It
                                            F1 : Help                PU/PD/+/- : Modify
                                            F5 : Old Values          (Shift) F2 : Color
                                            F6 : Load BIOS Defaults
                                            F7 : Load Setup Defaults
This section allows you to configure the system based on the specific features of the
installed chipset. This chipset manages bus speeds and access to system memory resources,
such as DRAM and the external cache. It also coordinates communications between the
conventional ISA bus and the PCI bus. It must be stated that these items should never need
to be altered. The default settings have been chosen because they provide the best operating

                                            50
conditions for your system. The only time you might consider making any changes would be
if you discovered that data was being lost while using your system.

DRAM Settings
The first chipset settings deal with CPU access to dynamic random access memory
(DRAM).
Auto Configuration
Pre-defined values for DRAM, cache.. Timing according to CPU type &
system clock.
The Choice: Enabled, Disabled.

Note: When this item is enabled, the pre-defined items will become
SHOW-ONLY.

AT Bus Clock
this item allows you to select 7.16MHZ, CLK2/2, CLK2/3, CLK2/4, CLK2/5,
CLK2/6, clocks. The default is clk2/4.

Asysc. SRAM Read/Write WS
This item allows you to select x-3-3-3, x-2-2-2. The default is x-3-3-3.

EDO Read WS
This item allows you to select x-3-3-3, x-2-2-2 . The default is x-3-3-3.

Page Mode Read WS
This item allows you to select x-3-3-3, x-4-4-4 . The default is x-3-3-3.

DRAM Write WS
This item allows you to select x-3-3-3, x-2-2-2 . The default is x-2-2-2.

CPU to DRAM Page Mode
The default is Disabled.

DRAM Refresh Period
This item allows you to select 15us, 30us, 60us, 120us.         The default is 60us.

DRAM Date Integrity Mode
This item allows you to select between two methods of DRAM error checking,
ECC and Parity. The default is Parity.
Pipelined Function
This item allows you to select Disabled, Enabled, Turbo. The default is

                                           51
Disabled.


16 Bit ISA I/O, Mem Command WS
Th



◦ Jabse Service Manual Search 2024 ◦ Jabse PravopisonTap.bg ◦ Other service manual resources online : FixyaeServiceinfo