                                                                                                                                           DLV-100

                                                                                                                                    Ref. No. 3701

                                       SERVICE MANUAL                                                                                Nov, 2001




Digital Light Processing Projector
                      MODEL DLV-100

                 CEL
                       CAN




                             EN T ER
                      CT
                   LE
                SE
                                             SS      E
                                            ST    CC
                                         JU              DA
       U
       N




           ME                          AD UTO                 AR
                                         A                            C
                                                                   PC

                                                                                                                            INPUT

                                                                            CE
                                                                          UR
                                                                                 SO
                                                                                      Y
                                                                                               DB
                                                                                            AN
                                                                                          ST N /
                                                                                            O

                                                                                                          R
                                                                                                       WE
                                                                                                    PO        US
                                                                                                           AT
                                                                                                        ST




UUD                        100 - 120 / 200 - 240 V AC, 50 / 60 Hz



      SAFETY-RELATED COMPONENT
      WARNING!!
      COMPONENTS IDENTIFIED BY MARK                                                                                ON THE
      SCHEMATIC DIAGRAM AND IN THE PARTS LIST ARE
      CRITICAL FOR RISK OF FIRE AND ELECTRIC SHOCK.
      REPLACE THESE COMPONENTS WITH ONKYO
      PARTS WHOSE PART NUMBERS APPEAR AS SHOWN
      IN THIS MANUAL.
      MAKE LEAKAGE-CURRENT OR RESISTANCE
      MEASUREMENTS TO DETERMINE THAT EXPOSED
      PARTS ARE ACCEPTABLY INSULATED FROM THE
      SUPPLY CIRCUIT BEFORE RETURNING THE
      APPLIANCE TO THE CUSTOMER.
                                                                                                       DLV-100



1. Application
  This specification sheet applies for DLV-100.
     Model               DLV-100
     NEC Model code 01152009

2. General
 2.1 Operation temperature range
      +5 ~ +35 degree C (Humidity 20-80%RH, not in the dewfall.)
 2.2 Storage temperature range
      -10 ~ +50 degree C
 2.3 Power source
      100 ~ 120 VAC / 200 ~ 240 VAC +/-10%, 50 / 60 Hz
 2.4 Input Current
      2.2/1.1A (MAX.)
 2.5 Inspection condition
      Inspection shall be done by AC120V / 60 Hz unless no rule is specified.
      As for the projection condition, the screen is perpendicularly installed to the set and the
      projection screen is in WIDE condition of 60 inches. When test, inspector shall be 2 +/- 0.3 m
      away from the screen.




      Screen

                                              Inspector


                              2 0.3 m

                                         Fig. 1   Condition

3. Main parts specifications
 3.1 DMD panel
      Single Chip Digital Micromirror Device(DMD)
     1024 x 768 pixels
 3.2 Lens
     Manual zoom and focus
     F-no.=2.61~2.84, f=28.35~34.02mm
 3.3 Lamp
     135W DC Lamp
      Average lifetime 1,000H
      The definition of average lifetime is the time that light becomes half with the continuous
      lighting-up.
      (Notes)
      The lamp bulb can be ruptured, while using a projector.
     When the lamp bulb is ruptured, there is a small crack and pieces of glass, which may be
     scattered in the lamp case.
                                                                                                  DLV-100



4. Electric specifications
 4.1 Input signal band width
            RGB             80MHz
            Video           6.5MHz
 4.2 Graduation
            256 grade full color (16,777,216 color)
 4.3 Display resolution
            NTSC/PAL/YCbCr                    550TV lines
            SECAM                             300TV lines
            RGB                               1024dots(H) 768dots(V)
 4.4 Input terminal
            RGB             1 input: Mini D-SUB 15pin
                                      YCbCr:shares with the RGB terminal
            VIDEO           1 input: RCA
            S-VIDEO         1 input: DIN 4pin
            Audio           1 input: Stereo mini jack
            PC Control      1 input: DIN 8pin
            USB             1 input: Type A
            PC Card         1 input: CompactFlash
 4.5 PC Card Viewer
            This Viewer can display the JPEG/BMP image which is preserved in CompactFlash (CF).
            CF correspond to SanDisk CF 128Mbytes media.
 4.6 Y/C Separation
            NTSC/PAL
 4.7 Input signal (RGB)
            Horizontal Freq.         15 ~ 100KHz(RGB: 24KHz or over)
            Vertical freq.           50 ~ 120Hz
            Pixel clock freq.         Less than 100MHz
            Capable resolution        UXGA 1600dot(H) 1200dot(V) Max.
            Sync system               Separate Sync/Composite Sync/Sync on G
 4.8 Input signal level
            RGBHV Input              R,G,B            0.7Vp-p / 75ohm positive
                                      Y               1.0Vp-p / 75ohm positive
                                      Cb,Cr(Pb,Pr)    0.7Vp-p / 75ohm
                                      H/V Sync        4.0Vp-p / TTL posi./nega
                                      Composite Sync 4.0Vp-p / TTL posi./nega
                                      Sync on G       0.3Vp-p / 75 ohm negative
            VIDEO                    1.0Vp-p / 75 ohm
            S-VIDEO         Y:       1.0Vp-p / 75 ohm
                            C:       0.283Vp-p / 75 ohm
            AUDIO                    0.5Vrms / 22 K ohm
 4.9 Audio output
           1W monaural Speaker
                                                                                                  DLV-100


4.10 On Screen Display
          1. Pull down menu
                Basic/Custom menu <> Advanced menu
          2. Multilingual menu
                English / French /German / Italian / Japanese / Spanish / Swedish
4.11 Remote
          Palm type remote unit
4.12 Input current
          2.2A 100 ~ 120VAC/1.1A 200 ~ 240VAC
4.13 Plug & Play data
           Tab.1 EDID data
                 0    1    2   3    4   5     6     7    8   9    A    B    C    D   E    F
           00 00 FF FF FF FF FF FF 00 38 A3 D3 00 01 00                              00   00
           10 27 0B 01 02 0E 00 00 78 0A 34 70 95 59 4F                              88   26
           20 15 4A 53 FF FF 80 31 59 45 59 61 59 71 59                              81   4F
           30 81 99 A9 4F 01 01 EA 24 00 60 41 00 28 30                              30   60
           40 13 00 00 00 00 00 00 1E F9 15 20 F8 30 58                              1F   20
           50 20 40 13 00 00 00 00 00 00 1E 00 00 00 FD                              00   32
           60 78 0F 64 0A 00 0A 20 20 20 20 20 20 00 00                              00   FC
           70 00 4F 4E 4B 59 4F 20 44 4C 56 31 30 30 0A                              00   E2

4.14 Safety test
    (1)Dielectric strength test
      By the test vessel, under the condition of main power supply ON,
      Apply AC voltage of 1500V(+50/-0) ,at 50Hz or 60Hz for 1.5~2 second between power supply
      circuit part(AC) and exposure metal part.
      No insulation destruction, catching fire, and so on is allowed.
     (2) Insulation resistance test
      Measure insulation resistance between power supply circuit part(AC) and exposure metal
      part (FG) under the condition of main power ON(Stand By mode) by using 500V insulate
      ohmmeter.
      Insulation resistance shall be more than 50M ohm.
    (3)Leakage electric current test
      Measure leakage electric current by the leakage ammeter under the condition of main power
      supply ON (Standby condition). The measurement impedance should be measured by
      the build in resistor of 1.5K , with the bypass capacitor of 0.15 F.
      The leakage electric current should be less than 2mA each.

4.15 Signal table
    Refer to Tab.2.
                                                                                                        DLV-100



5. Optical specifications
 5.1 Brightness
     Normal            : 630 ANSI lumens minimum
     High Brightness : 750 ANSI lumens minimum
        It contains 5 % of measurement tolerance.
 5.2 Contrast ratio
     700 : 1 typical
        It contains 20 % of measurement tolerance.
 5.3 Relative illumination
     More than 70%
     On the screen which is shown in figure 2, apply following formula with condition of
     Aj as the illumination of point j.
     Relative illumination = ( A1 + A3 + A7 + A9 ) / ( 4 x A5 ) x 100 [%]




                                  Fig.2 The measurement point
 5.4 Chromaticity
     x=0.234 



◦ Jabse Service Manual Search 2024 ◦ Jabse PravopisonTap.bg ◦ Other service manual resources online : FixyaeServiceinfo