08360-90134 8360L Users Feb99


>> Download 08360-90134 8360L Users Feb99 documenatation <<

Text preview - extract from the document
HP 8360 L-Series Swept CW Generator
(Including Options 001, 004, and 008)
User's Guide


SERIAL NUMBERS
This manual applies directly to any swept CW generator with the
model and serial number prefix combination shown below. You
may have to modify this manual so that it applies directly to your
instrument version. Refer to the "Instrument History" chapter.
HP 83623L/3OL/4OL/5OL
3844A and below




        HEWLETT
Pii     PACKARD

HP Part No. 08380-90134
Printed in USA February 1999 Supersedes: September 1997
Notice                   The information contained in this document is subject to change
                         without notice.
                         Hewlett-Packard makes no warranty of any kind with regard to this
                         material, including but not limited to, the implied warranties of
                         merchantability and fitness for a particular purpose. Hewlett-Packard
                         shall not be liable for errors contained herein or for incidental
                         or consequential damages in connection with the furnishing,
                         performance, or use of this material.

     Restricted Rights   Use, duplication, or disclosure by the U.S. Government is subject
               Legend    to restrictions as set forth in subparagraph (c) (1) (ii) of the
                         Rights of Technical Data and Computer Software clause at DFARS
                         252.227-7013 for DOD agencies, and subparagraphs (c) (1) and
                         (c) (2) of the C ommercial Computer Software Restricted Rights
                         clause at FAR 52.227-19 for other agencies.




                         @ Copyright Hewlett-Packard Company 1996, 1997, 1999
                         All Rights Reserved. Reproduction, adaptation, or translation
                         without prior written permission is prohibited, except as allowed
                         under the copyright laws.
                         1400 Fountaingrove Parkway, Santa Rosa, CA 95403-1799, USA
Certification   Hewlett-Packard Company certifies that this product met its
                published specifications at the time of shipment from the factory.
                Hewlett-Packard further certifies that its calibration measurements
                are traceable to the United States National Institute of Standards
                and Technology, to the extent allowed by the Institute's calibration
                facility, and to the calibration facilities of other International
                Standards Organization members.




Warranty        This Hewlett-Packard instrument product is warranted against
                defects in material and workmanship for a period of one year from
                date of shipment. During the warranty period, Hewlett-Packard
                Company will, at its option, either repair or replace products which
                prove to be defective.
                For warranty service or repair, this product must be returned to a
                service facility designated by Hewlett-Packard. Buyer shall prepay
                shipping charges to Hewlett-Packard and Hewlett-Packard shall pay
                shipping charges to return the product to Buyer. However, Buyer
                shall pay all shipping charges, duties, and taxes for products returned
                to Hewlett-Packard from another country.
                Hewlett-Packard warrants that its software and firmware designated
                by Hewlett-Packard for use with an instrument will execute
                its programming instructions when properly installed on that
                instrument. Hewlett-Packard does not warrant that the operation
                of the instrument, or software, or firmware will be uninterrupted or
                error-free.
                L IMITATION   OF   WARRANTY
                  The foregoing warranty shall not apply to defects resulting from
                  improper or inadequate maintenance by Buyer, Buyer-supplied
                  software or interfacing, unauthorized modification or misuse,
                  operation outside of the environmental specifications for the
                  product, or improper site preparation or maintenance.
                  NO OTHER WARRANTY IS EXPRESSED OR IMPLIED.
                  HEWLETT-PACKARD SPECIFICALLY DISCLAIMS THE
                  IMPLIED WARRANTIES OF MERCHANTABILITY AND
                  FITNESS FOR A PARTICULAR PURPOSE.
                EXCLUSIVE REMEDIES
                  THE REMEDIES PROVIDED HEREIN ARE BUYER'S SOLE
                  AND EXCLUSIVE REMEDIES. HEWLETT-PACKARD SHALL
                  NOT BE LIABLE FOR ANY DIRECT, INDIRECT, SPECIAL,
                  INCIDENTAL, OR CONSEQUENTIAL DAMAGES, WHETHER
                  BASED ON CONTRACT, TORT, OR ANY OTHER LEGAL
                  THEORY.


                                                                                       ...
                                                                                       III
Assistance        Product maintenance agreements and other customer assistance
                  agreements are available for Hewlett-Packard products. For any
                  assistance, contact your nearest Hewlett-Packard Sales and Service
                  Ofice.




Safety Notes      The following safety notes are used throughout this manual.
                  Familiarize yourself with each of the notes and its meaning before
                  operating this instrument.

       WARNING    Warning denotes a hazard. It calls attention to a procedure which, if
                  not correctly performed or adhered to, could result in injury or loss
                  of life. Do not proceed beyond a warning note until the indicated
                  conditions are fully understood and met.


        CAUTION   Caution denotes a hazard. It calls attention to a procedure that, if
                  not correctly performed or adhered to, would result in damage to or
                  destruction of the instrument. Do not proceed beyond a caution sign
                  until the indicated conditions are fully understood and met.




iv
General Safety
Considerations
        WARNING   n    No operator serviceable parts inside. Refer servicing to qualified
                      personnel. To prevent electrical shock, do not remove covers.
                  n   For continued protection against fire hazard replace line fuse only
                      with same type and rating (F 5A/250V). The use of other fuses or
                      material is prohibited.
                  w This is a Safety Class I product (provided with a protective earthing
                    ground incorporated in the power cord). The mains plug shall only
                    be inserted in a socket outlet provided with a protective earth
                    contact. Any interruption of the protective conductor, inside or
                    outside the instrument, is likely to make the instrument dangerous.
                    Intentional interruption is prohibited.
                  n   If this instrument is used in a manner not specified by
                      Hewlett-Packard Co., the protection provided by the instrument may
                      be impaired. This product must be used in a normal condition (in
                      which all means for protection are intact) only.
                  w Position the instrument according to the enclosure protection
                    provided. This instrument does not protect against the ingress of
                    water. This instrument protects against finger access to hazardous
                    parts within the enclosure.




                                                                                            V
     CAUTION   n    Before switching on this instrument, make sure that the line
                   voltage selector switch is set to the voltage of the power supply and
                   the correct fuse is installed.
               n    Always use the three-prong ac power cord supplied with this
                   instrument. Failure to ensure adequate earth grounding by not
                   using this cord may cause instrument damage.
               n    Before switching on this product, make sure that the line voltage
                   selector switch is set to the voltage of the power supply and
                   the correct fuse is installed. Assure the supply voltage is in the
                   specified range.
               n    Ventilation Requirements: When installing the instrument in a
                   cabinet, the convection into and out of the instrument must not be
                   restricted. The ambient temperature (outside the cabinet) must be
                   less than the maximum operating temperature of the instrument
                   by 4 "C for every 100 watts dissipated in the cabinet. If the total
                   power dissipated in the cabinet is greater than 800 watts, then
                   forced convection must be used.
               n    This product is designed for use in Installation Category II and
                   Pollution Degree 2 per IEC 1010 and 664, respectively.


        Note   The detachable power cord is the instrument disconnecting device.
               It disconnects the mains circuits from the mains supply before other
               parts of the instrument. The front panel switch is only a standby
               switch and is not a LINE switch.




vi
PREFACE               This manual provides user information for the HP 8360 L-Series
                      Swept CW Generator.




Instruments Covered   This manual applies to instruments having a serial number prefix
                      listed on the title page (behind the "Documentation Map" tab).
By This Manual        Some changes may have to be made to this manual so that it
                      applies directly to each instrument; refer to Chapter 5, "Instrument
                      History", to see what changes may apply to your instrument.
                      A serial number label (Figure O-l) is attached to the instrument's
                      rear panel. A prefix (four digits followed by a letter), and a suffix
                      (five digits unique to each instrument), comprise the instrument
                      serial number.

                                                              SERIAL NUMBER
                                                                    h
                                                          I               \
                                                               PREFIX   SUFFIX
                                                              -A


                                                    SER       1234A 12345
                                             \I
                                 INSTALLED
                                   OPTIONS
                                             !



                                      Figure O-l. Typical Serial Number Label




User's Guide          Tabs divide the major chapters of this manual. The contents of each
                      chapter is listed in the Table of Contents.
Organization



HP 8360 L-Series      Documentation Map
Documentation         For a pictorial representation of the HP 8360 L-Series documentation,
                      see the `Documentation Map" at the front of this manual.
                      Ordering Manuals

                      A manual part number is listed on the title page of this manual.
                      You may use it to order extra copies of this manual. See
                       "Replaceable Parts" in HP 8360 B-Series Swept Signal Generator/
                      HP 8360 L-Series Swept CW Generator Service Guide for a complete
                      list of HP 8360 documentation and ordering numbers.




                                                                                              vii
Typeface      The following conventions are used in the HP 8360 L-Series
              documentation:
Conventions
              Italics Italic type is used for emphasis, and for titles of manuals and
              other publications.
              Computer Computer type is used for information displayed on the
              instrument. For example: In this sequence, POWER LEVEL is displayed.
              (Hardkeys) Instrument keys are represented in "key cap." You are
              instructed to press a hardkey.
               Softkeys Softkeys are located just below the display, and their
              functions depend on the current display. These keys are represented
              in "softkey." You are instructed to select a softkey.




Regulatory    This product has been designed and tested in accordance with IEC
              Publication 1010, Safety Requirements for Electronic Measuring
Information   Apparatus, and has been supplied in a safe condition. The
              instruction documentation contains information and warnings
              which must be followed by the user to ensure safe operation and to
              maintain the instrument in a safe condition.




 ...
VIII
Manufacturer's
Declaration
            Note   This is to certify that this product meets the radio frequency
                   interference requirements of Directive FTZ 1046/1984. The German
                   Bundespost has been notified that this equipment was put into
                   circulation and has been granted the right to check the product type
                   for compliance with these requirements.
                   Note: If test and measurement equipment is operated with
                   unshielded cables and/or used for measurements on open set-ups, the
                   user must insure that under these operating conditions, the radio
                   frequency interference limits are met at the border of his premises.
                   Model HP 8360 L-Series Swept CW Generator


            Note   Hiermit wird bescheinigt, dass dieses Gerat/System in
                   fibereinstimmung mit den Bestimmungen von Postverfiigung 1046/84
                   funkentst"rt ist.
                   Der Deutschen Bundespost wurde das Inverkehrbringen dieses
                   Gerates/Systems angezeight und die Berechtigung zur Uberpriifung
                   der Serie auf Einhaltung der Bestimmungen eingeraumt.
                   Zustzinformation fiir Mess-und Testgerate:
                   Werden Mess- und Testgerate mit ungeschirmten Kabeln und/oder
                   in offenen Messaufbauten verwendet, so ist vom Betreiber
                   sicherzustellen, dass die Funk-Entst"rbestimmungen unter
                   Betriebsbedingungen an seiner Grundstiicksgrenze eingehalten
                   werden.




                                                                                      ix
Declaration of
Conformity

                               DECLARATION OF CONFORMITY
                                            aomrding to lSO/lEC Guide 22 and EN 45014


         hanufacturetis Name:                               Hewlett-Packard Co.

         lanufactureh Address:                              Microwave Instruments Division
                                                            1400 Fountaingrove Parkway
                                                            Santa Rosa, CA 95403-1799
                                                            USA
         declares that the products

          Product Name:                                     Synthesized Sweeper

          Model Numbers:                                    HP 83623L, HP 8363OL, HP 836401.
                                                            HP 83650L


          Product Options:                                  This declaration covers all options of the
                                                            above products.

        :onform to the following Product specifications:

          Safety: IEC 348:1978/HD 401 S1:1981
                  CAN/CSA-C22.2 No. 231 (Series M-89)

          EMC: CISPR 11:1990/EN                55011:1991 Group I, Class A
                IEC 801-2:1984/EN              50082-1:1992 4 kV CD, 8 kV AD
                IEC 801-3:1984/EN               50082-1:1992 3 V/m, 27-500 MHz
                IEC 801-4:1988/EN               50082-I:1992 0.5 kV Sig. Lines, 1 kV Power Lines

                    IEC 555-2:1982 + Al:1985 I EN 60555-2:1987
                    IEC 555-3:1982 + Al:1990 / EN 60555-3:1987 + Al:1991

         Supplementary Information:

         -hese products herewith comply with the requirements of the Low Voltage Directive
         `3/23/EEC and the EMC Directive 89/336/EEC and carry the CE-marking accordingly.

         Voduct safety qualification testing for these products was performed prior to 1
         December 1993.


         Santa Rosa, California, USA             19 Dec. 1996
                                                                      J                                         Manager



         European Contact: Your local Hewlett-Packard Sales and Service Office or Hewlett-Packard GmbH. Deparlment   HQ-TRE.
                           Herrenbarger Slrasse 130, D-71 034 BBblingen. Germany (FAX +497031-l 4-3143)




X
Compliance with     This is to declare that this instrument is in conformance with the
                    German Regulation on Noise Declaration for Machines (Laermangabe
German Noise
                    nach der Maschinenlaermrerordnung -3.GSGV Deutschland).
Requirements
                           I       Acoustic   Noise   Emmission/Geraeuschemission   I
                               LpA <70 dB                   LpA <70 dB
                               Operator position            am Arbeitsplatz
                               Normal position              normaler Betrieb
                               per IS) 7779                 nach DIN 45635 t.19




Instrument   Markings A
                      !           The instruction documentation symbol. The product is
                                  marked with this symbol when it is necessary for the
                                  user to refer to the instructions in the documentation.
                   CC             The CE mark is a registered trademark of the European
                                  Community.


                                  The CSA mark is a registered trademark of the
                                  Canadian Standards Association.


                   "ISMl-A"       This is a symbol of an Industrial Scientific and Medical
                                  Group 1 Class A product.

                       I          This is an ON symbol. The symbol ON is used to mark
                                  the position of the instrument power line switch.


                   I              This is an ON symbol. The symbol ON is used to mark
                                  the position of the instrument power line switch.


                                  This is a STANDBY symbol. The STANDBY symbol is
                   0
                                  used to mark the position of the instrument power line
                                  switch.
                                  This is an OFF symbol. The OFF symbol is used to
                   I
                                  mark the position of the instrument power line switch.


                   N              This is an AC symbol. The AC symbol is used to
                                  indicate the required nature of the line module input
                                  power.




                                                                                             xi
                           Table O-l. Hewlett-Packard Sales and Service Offices
                                                 UNITED STATES


      Instrument Support Center
      Hewlett-Packard Company
      (800) 403-0801


                                        EUROPEAN FIELD OPERATIONS


      Headquarters                      France                           Germany
      Hewlett-Packard S.A.              Hewlett-Packard France           Hewlett-Packard GmbH
      150, Route du Nant-d'Avri1        1 Avenue Du Canada               Hewlett-Packard Strasse
      1217 Meyrin a/Geneva              Zone D'Activite De Courtaboeuf   61352 Bad Homburg v.d.H
      Switzerland                       F-91947 Les Ulis Cedex           Germany
      (41 22) 780.8111                  France                           (49 6172) 16-O
                                        (33 1) 69 82 60 60
      Great Britain
      Hewlett-Packard Ltd.
      Eskdale Road, Winnersh Triangle
      Wokingham, Berkshire RG41 5DZ
      England
      (44 734) 696622


                                        INTERCON FIELD OPERATIONS


      Headquarters                      Australia                        Canada
      Hewlett-Packard Company           Hewlett-Packard Australia Ltd.   Hewlett-Packard (Canada) Ltd.
      3495 Deer Creek Road              31-41 Joseph Street              17500 South Service Road
      Palo Alto, California, USA        Blackburn, Victoria 3130         Trans-Canada Highway
      94304-1316                        (61 3) 895-2895                  Kirkland, Quebec H9J 2X8
      (415) 857-5027                                                     Canada
                                                                         (514) 697-4232

      China                             Japan                            Singapore
      China Hewlett-Packard Company     Hewlett-Packard Japan, Ltd       Hewlett-Packard Singapore (Pte.) Ltd.
      38 Bei San Huan Xl Road           9-1 Takakura-Cho, Hachioji       150 Beach Road
      Shuang Yu Shu                     Tokyo 192, Japan                 #29-00 Gateway West
      Hai Dian District                 (81 426) 60-2111                 Singapore 0718
      Beijing, China                                                     (65) 291-9088
      (86 1) 2566888

      Taiwan
      Hewlett-Packard Taiwan
      8th Floor, H-P Building
      337 Fu Hsing North Road
      Taipei, Taiwan
      (886 2) 712-0404




xii
Contents
           1.   Getting Started
                What Is In This Chapter . . . . . . . . . . . .           l-l
                How To Use This Chapter . . . . . . . . . . . .           l-2
                   Equipment Used In Examples . . . . . . . . .           l-2
                Introducing the HP 8360 L-Series Swept CW
                    Generators . . . . . . . . . . . . . . . . .           1-3
                Display Area . . . . . . . . . . . . . . . . . .           l-4
                Entry Area . . . . . . . . . . . . . . . . . .             1-5
                CW Operation and Start/Stop Frequency Sweep . .            1-6
                   CW Operation . . . . . . . . . . . . . . . .            l-6
                   Start/Stop Frequency Sweep . . . . . . . . . .          l-6
                Center Frequency/Span Operation . . . . . . . .            l-8
                Power Level and Sweep Time Operation . . . . . .         l-10
                   Power Level Operation . . . . . . . . . . . .         l-10
                   Sweep Time Operation . . . . . . . . . . . .          l-10
                Continuous, Single, and Manual Sweep Operation .         l-12
                Marker Operation . . . . . . . . . . . . . . .           1-14
                Saving and Recalling an Instrument State . . . . .       1-16
                Power Sweep and Power Slope Operation . . . . .          1-18
                   Power Sweep Operation . . . . . . . . . . . .         1-18
                   Power Slope Operation . . . . . . . . . . . .         1-19
                Getting Started Advanced . . . . . . . . . . . .         l-21
                Externally Leveling the Swept CW Generator . . .         l-23
                   Leveling with Detectors/Couplers /Splitters . . .     l-23
                     External Leveling Used With the Optional Step
                         Attenuator . . . . . . . . . . . . . . .        l-26
                   Leveling with Power Meters . . . . . . . . . .        l-27
                   Leveling with MM-wave Source Modules . . . . .        l-28
                Working with Mixers/Reverse Power Effects . . . .        l-30
                Working with Spectrum Analyzers/Reverse Power
                    Effects . . . . . . . . . . . . . . . . . . .        l-32
                Optimizing Swept CW Generator Performance . . .          l-33
                   Creating and Applying the User Flatness Correction
                      Array . . . . . . . . . . . . . . . . . .          l-33
                     Creating a User Flatness Array Automatically,
                         Example 1 . . . . . . . . . . . . . . .         l-34
                     Creating a User Flatness Array, Example 2 . .       1-36
                     Swept mm-wave Measurement with Arbitrary
                          Correction Frequencies, Example 3 . . . .      1-39
                     Scalar Analysis Measurement with User Flatness
                          Corrections, Example 4 . . . . . . . . .       l-43
                  Using Detector Calibration . . . . . . . . . .         l-47

                                                                   Contents-l
               Using the Tracking Feature . . . . . .        .    .    .    .   l-49
                  Peaking . . . . . . . . . . . . . .       .    .    .    .    l-49
                  Tracking    . . . . . . . . . . . . .      .    .    .    .   1-49
             ALC Bandwidth Selection . . . . . . . .         .    .    .    .   l-50
             Using Step Sweep      . . . . . . . . . . .     .    .    .    .   1-51
             Creating and Using a Frequency List . . .       .    .    .    .   l-52
             Using the Security Features . . . . . . .       .    .    .    .   l-53
             Changing the Preset Parameters . . . . .        .    .    .    .   l-54
             Getting Started Programming . . . . . .         .    .    .    .   l-55
             HP-IB General Information . . . . . . .         .    .    .    .   l-56
               Interconnecting Cables . . . . . . . .        .    .    .    .   1-56
               Instrument Addresses . . . . . . . . .        .    .    .    .   1-56
               HP-IB Instrument Nomenclature . . . .         .    .    .    .   1-56
                  Listener . . . . . . . . . . . . . .      .    .    .    .    l-56
                  Talker. . . . . . . . . . . . . . .       .    .    .    .    l-56
                  Controller . . . . . . . . . . . . .      .    .    .    .    l-56
               Programming the Swept CW Generator .          .    .    .    .   l-56
               HP-IB Command Statements . . . . .            .    .    .    .   l-57
                  Abort . . . . . . . . . . . . . . .       .    .    .    .    l-57
                  Remote . . . . . . . . . . . . . .        .    .    .    .    l-58
                  Local Lockout . . . . . . . . . . .       .    .    .    .    l-58
                  Local . . . . . . . . . . . . . . .       .    .    .    .    l-59
                  Clear . . . . . . . . . . . . . . .       .    .    .    .    l-59
                  output . . . . . . . . . . . . . .        .    .    .    .    l-60
                  Enter . . . . . . . . . . . . . . .       .    .    .    .    1-61
             Getting Started with SCPI . . . . . . .         .    .    .    .   1-63
             Definitions of Terms . . . . . . . . . .       .    .    .    .    l-63
               Standard Notation . . . . . . . . . .        .    .    .    .    l-64
                  Command Mnemonics        . . . . . . .    .    .    .    .    l-64
                  Angle Brackets . . . . . . . . . . .      .    .    .    .    l-64
               How to Use Examples . . . . . . . . .        .    .    .    .    1-64
                  Command Examples . . . . . . . .          .    .    .    .    l-64
                  Response Examples . . . . . . . . .       .    .    .    .    l-65
             Essentials for Beginners . . . . . . . . .     .    .    .    .    l-66
               Program and Response Messages        . . .   .    .    .    .    l-66
                  Forgiving Listening and Precise Talking    .    .    .    .   l-66
                  Types of Commands . . . . . . . .         .    .    .    .    l-67
               Subsystem Command Trees . . . . . .          .    .    .    .    l-68
                  The Command Tree Structure . . . .        .    .    .    .    l-68
                  Paths Through the Command Tree . .        .    .    .    .    l-68
               Subsystem Command Tables . . . . . .         .    .    .    .    1-71
                  Reading the Command Table . . . .         .    .    .    .    1-71
                  More About Commands . . . . . . .         .    .    .    .    l-72
                     Query and Event Commands . . . .       .    .    .    .    l-72
                     Implied Commands . . . . . . . .       .    .    .    .    l-72
                     Optional Parameters . . . . . . .      .    .    .    .    l-72
                  Program Message Examples . . . . .        .    .    .    .    l-72
                 Parameter Types . . . . . . . . . .        .    .    .    .    l-73
                     Numeric Parameters . . . . . . .       .    .    .    .    l-73
                     Extended Numeric Parameters . . .      .    .    .    .    l-74
                     Discrete Parameters . . . . . . .      .    .    .    .    l-75

Contents-2
       Boolean Parameters . . . . . . . . . . .         l-75
  Reading Instrument Errors . . . . . . . . . .         l-76
  Example Programs . . . . . . . . . . . . . .          1-77
     Example Program . . . . . . . . . . . . .          l-77
       Description . . . . . . . . . . . . . . .        l-77
       Program Listing . . . . . . . . . . . . .        l-77
       Program Comments . . . . . . . . . . .           l-78
Details of Commands and Responses . . . . . . .         l-80
  In This Subsection . . . . . . . . . . . . . .        l-80
  Program Message Syntax . . . . . . . . . . .          l-80
     Subsystem Command Syntax . . . . . . . .           1-81
     Common Command Syntax . . . . . . . . .            1-81
  Response Message Syntax . . . . . . . . . . .         l-82
  SCPI Data Types       . . . . . . . . . . . . . .     l-83
     Parameter Types   . . . . . . . . . . . . . .      l-83
        Numeric Parameters . . . . . . . . . . .        l-83
        Extended Numeric Parameters . . . . . . .       l-84
        Discrete Parameters . . . . . . . . . . .       l-85
        Boolean Parameters . . . . . . . . . . .        l-85
     Response Data Types . . . . . . . . . . . .        l-85
        Real Response Data . . . . . . . . . . .        l-85
        Integer Response Data . . . . . . . . . .       1-86
        Discrete Response Data . . . . . . . . . .      l-86
        String Response Data . . . . . . . . . . .      l-86
Programming Typical Measurements . . . . . . .          1-87
  In This Subsection . . . . . . . . . . . . . .        l-87
  Using the Example Programs . . . . . . . . .          l-87
     Use of the Command Tables . . . . . . . . .        l-88
  HP-IB Check, Example Program 1 . . . . . . .           l-90
     Program Comments . . . . . . . . . . . .            l-90
  Local Lockout Demonstration, Example Program 2         l-91
     Program Comments . . . . . . . . . . . .            l-92
  Setting Up A Typical Sweep, Example Program 3           l-93
     Program Comments . . . . . . . . . . . .             l-93
  Queries, Example Program 4 . . . . . . . . . .          l-95
     Program Comments . . . . . . . . . . . .             l-95
  Saving and Recalling States, Example Program 5 .        l-97
     Program Comments . . . . . . . . . . . .             l-97
   Looping and Synchronization, Example Program 6         l-99
     Program Comments        . . . . . . . . . . . .      1-99
  Using the *WA1 Command, Example Program 7 .           l-101
     Program Comments        . . . . . . . . . . . .    l-101
   Using the User Flatness Correction Commands,
       Example Program 8 . . . . . . . . . . . .        l-103
Programming the Status System . . . . . . . . .         l-106
   In This Subsection . . . . . . . . . . . . . .       l-106
   General Status Register Model . . . . . . . . .      l-106
      Condition Register . . . . . . . . . . . . .      l-106
     Transition Filter . . . . . . . . . . . . . .      l-107
     Event Register . . . . . . . . . . . . . . .       l-107
      Enable Register . . . . . . . . . . . . . .       l-107

                                                   Contents-3
                       An Example Sequence       . . . . . . . . . . .    l-107
                  Programming the Trigger System . . . . . . . . .        l-109
                    In This Subsection . . . . . . . . . . . . . .        l-109
                    Generalized Trigger Model . . . . . . . . . . .       l-109
                       Overview . . . . . . . . . . . . . . . . .         l-109
                       Details of Trigger States . . . . . . . . . . .    l-110
                         Inside the Idle State . . . . . . . . . . .      l-111
                         Inside the Initiate State . . . . . . . . . .    l-111
                         Inside Event Detection States . . . . . . .      1-112
                         Inside the Sequence Operation State . . . .      l-114
                    Common Trigger Configurations . . . . . . . .         l-115
                       The INIT Configuration . . . . . . . . . . .       1-115
                       The TRIG Configuration . . . . . . . . . .         1-116
                    Description of Triggering in the HP 8360 L-Series
                        Swept CW Generators . . . . . . . . . . .         l-117
                       Advanced Trigger Configurations . . . . . . .      1-118
                    Trigger Keyword Definitions . . . . . . . . . .       1-118
                       ABORt . . . . . . . . . . . . . . . . . .          l-118
                      IMMediate      . . . . . . . . . . . . . . . .      1-118
                       ODELay      . . . . . . . . . . . . . . . . .      1-118
                       SOURce . . . . . . . . . . . . . . . . . .         1-119
                  Related Documents . . . . . . . . . . . . . . .         l-120
                    The International Institute of Electrical and
                        Electronics Engineers. . . . . . . . . . . .      l-120
                    Hewlett-Packard Company . . . . . . . . . . .         l-120

             2. Operating and Programming Reference
                  How To Use This Chapter . . . . . . . . . . . .           2-1

             A.
                  Address . . . . . . . . . . . . . . . . . . . .          A-l
                  Adrs Menu . . . . . . . . . . . . . . . . . .            A-l
                  (ALC). . . . . . . . . . . . . . . . . . . . .           A-3
                  ALC Bandwidth Select Auto . . . . . . . . . .           A-10
                  ALC Bandwidth Select High . . . . . . . . . .           A-10
                  ALC Bandwidth Select Low . . . . . . . . . .           A-11
                  ALC3WMenu . . . . . . . . . . . . . . . . .             A-11
                  Altrnate Regs . . . . . . . . . . . . . . . .           A-12
                   Amp1 Markers . . . . . . . . .    . . . . . . . .      A-13
                  ANALYZER STATUS REGISTER            . . . . . . . .     A-13
                  Arrow Keys . . . . . . . . . .     . . . . . . . .      A-16
                  [ASSIGN). . . . . . . . . .
                   . . . .                           . . . . . . .        A-17
                  Auto   Fill Incr . . . . . . . . . . . . . . . .        A-18
                  Auto   Fill #Pts . . . . . . . . . . . . . . . .        A-19
                  Auto   Fill Start . . . . . . . . . . . . . . .         A-20
                  Auto   Fill Stop . . . . . . . . . . . . . . . .        A-21
                  Auto   Track . . . . . . . . . . . . . . . . . .        A-22


Contents-4
B.
     BLankDisp . . . . . . . . . . . . . . . . . .                                           B-l

C.
     (CENTER) . . .
      . . .           . . . . . . . . . . . . . . .                                          C-l
      Center=Marker     ................                                                     c-2
      Clear Fault     .................                                                      c-2
      Clear Memory    .................                                                      c-3
     Clear Point      .................                                                      c-4
     CONNECTORS . . . . . . . . . . . . . . . .                                              c-4
     (CONT) . . . . . . . . . . . . . . . . . .
      . . .                                                                                 c-10
     CopyList . . . . . . . . . . . . . . . . . .                                           c-11
     CorPair Disable . . . . . . . . . . . . . . .                                          c-11
     Coupling Factor . . . . . . . . . . . . . . .                                          c-12
     (cw   . . . . . . . . . . . . . . . . . . . . .                                        c-12
     CW/CF Coupled            ................                                              c-13

D.
     Dblr Amp Menu . . . . . . . . . . . . . . . .                                           D-l
     Delete Menu . . . . . . . . . . . . . . . . .                                           D-2
     Delete All . . . . . . . . . . . . . . . . . .                                          D-2
     Delete Current . . . . . . . . . . . . . . . .                                          D-3
     Delete Undef . . . . . . . . . . . . . . . . .                                          D-3
     DeltaMarker . . . . . . . . . . . . . . . . .                                           D-4
     Delta Mkr Ref . . . . . . . . . . . . . . . .                                           D-5
     Disp Status . . . . . . . . . . . . . . . . .                                           D-5
     Doubler Amp Wode AUTO . . . . . . . . . . . .                                           D-7
     Doubler Amp Mode Off   ............                                                     D-7
     Doubler Arap Mode On . . . . . . . . . . . . .                                          D-8
     Dwell Coupled . . . . . . . . . . . . . . . .                                           D-9

E.
     8360Adrs    ..................                                                          E-l
     EnterCorr . . . . . . . . . . . . . . . . . .                                           E-l
     EnterFreq.. . . . . . . . . . . . . . . . .                                             E-2
     Enter List Dwell  ..............                                                        E-2
     Enter List Freq . . . . . . . . . . . . . . .                                           E-3
     Enter List Offset . . . . . . . . . . . . . .                                           E-4
     ENTRY KEYS . . . . . . . . . . . . . . . . .                                            E-4
     ENTRY ON/OFF)    .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .      E-5
     ExtDet Cal       .................                                                      E-5




                                                                                      Contents-5
             F.
                  Fault Menu . . . . . . . . . . . . . . . . . .                                       F-l
                  Fault Info 1 . . . . . . . . . . . . . . . . .                                       F-2
                  Fault Info 2 . . . . . . . . . . . . . . . . .                                       F-3
                  Fault Info 3 . . . . . . . . . . . . . . . . .                                       F-4
                  Fltness Menu . . . . . . . . . . . . . . . . .                                       F-5
                  (FLTNEss ON/OF)     .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   F-10
                  Freq Cal Menu       ................                                                F-11
                  Freq Follow       . . . . . . . . . . . . . . . . .                                 F-11
                  FREQUENCY     (e) . . . . . . . . . . . .
                                . . .                                                                 F-12
                  Freq Mult .       . . . . . . . . . . . . . . . . .                                 F-13
                  Freq Offset       .................                                                 F-14
                  FullUsr Cal       .................                                                 F-14

             G.
                  Global Dwell . . . . . . . . . . . . . . . . .                                      G-l
                  Global Offset . . . . . . . . . . . . . . . .                                       G-l

             H.
                  HP-IB Address . . . . . . . . . . . . . . . . .                                     H-l
                  HP-IB Menu . . . . . . . . . . . . . . . . . .                                      H-l

             L.
                  Leveling ModeALCof f . . . . . . . . . . . . .                                       L-l
                  Leveling ModeNorxtal . . . . . . . . . . . . .                                       L-2
                  Leveling ModeSearch . . . . . . . . . . . . .                                        L-2
                  Leveling PointExtDet   ............                                                  L-3
                  Leveling PointIntml    ............                                                  L-3
                  Leveling PointModule   ............                                                  L-4
                  Leveling PointPwrMtr   ............                                                  L-5
                  LINE SWITCH        . . . . . . . . . . . . . . . .                                   L-5
                  ListMenu . . . . . . . . . . . . . . . . . .                                         L-6
                  List Mode Pt TrigAuto . . . . . . . . . . . .                                        L-8
                  List Mode Pt TrigBus  ............                                                   L-9
                  List Mode Pt TrigExt  ............                                                   L-9
                  (TEL-) . . . . . . . . . . . . . . . . . .
                   . . .                                                                              L-10




Contents-6
     MI--M2 Sweep . . . . .............                               M-l
     Manual Sweep . . . . .............                               M-l
     (MARKER)   .   .   ..............
                            .   .   .                                 M-3
     Marker Mi . . . . . .............                                M-4
     Marker M2 . . . . .                .............                 M-5
     Marker M3 . . . . .                .............                 M-5
     Marker M4 . . . . .                .............                 M-6
     Marker M5 . . . . .                .............                 M-6
     Markers All Off . .                .............                 M-7
     Measure Corr All .                 .............                 M-7
     Measure Corr Current                 ............                M-8
     Measure Corr Undef                 .............                 M-8
     Meter Adss . . . . .               .............                 M-9
     INIOD) . . . . . . . .             .............                 M-9
     Module Menu . . . .                .............                M-10
     Module Select AUTO                 .............                M-11
     Module Select Front                .............                M-11
     Module Select None                 .............                M-12
     Module Select Rear                 .............                M-13
     more n/m . . . . . .               .............                M-13
     Mtr Meas Menu . . .                .............                M-14

P.
     Peak RF Always . . . . . . . . . . . . . . . .                   P-l
                                                                      P-2
                                        .............                 P-2
                                        .............                 P-5
                                                                      P-6
                                        . . . . . . . . . . . . .     P-7
                                                                      P-8
                                                                      P-9
                                        . . . . . . . . . . . . .    P-10
                                        . . . . . . . . . . . . .    P-11
                                                                     P-11
                                        . . . . . . . . . . . . .    P-12
                                        Analyzr . . . . . . . .      P-13
                                        CIIL . . . . . . . . . .     P-13
                                        SCPI . . . . . . . . . .     P-14
                                                                     P-15
     Pulse On/OffScal.ar . . . . . . . . . . . . .                   P-15
     Pwr Mtr Range . . . . . . . . . . . . . . . .                   P-16


                                                                Contents-7
             R.
                  (RECALL) . . . . . . . . . . . . . . . . . . . .                                          R-l
                   Ref Osc Menu . . . . . . . . . . . . . . . . .                                           R-l
                  @Eqz-- . . . . . . . . . . . . . . . . . .                                                R-2
                  ROTARY KNOB . . . . . . . . . . . . . . . .                                               R-2

             S.
                  LSAVE) . . . . . . . . . . . . . . . . . . . . .                                          S-l
                  SaveLock . . . . . . . . . . . . . . . . . .                                              s-2
                  Save User Preset    ..............                                                        s-2
                  SCPI Conformance Information . . . . . . . . .                                            s-3
                  SCPI COMMAND SUMMARY                                                                     s-12
                  SCPI STATUS REGISTER STRUbitiRi . : : : :                                                S-48
                  Security Menu . . . . . . . . . . . . . . . .                                            s-50
                  Selftest (Full) . . . . . . . . . . . . . . .                                            s-51
                  SetAtten . . . . . . . . . . . . . . . . . .                                             s-51
                  [piEiF) . . . . . . . . . . . . . . . . . .
                   . . .                                                                                   S-52
                  Software Rev . . . . . . . . . . . . . . . . .                                           S-52
                  @KJ . . . . . . . . . . . . . . . . . . . . .                                            s-53
                  (START) . . . . . . . . . . . . . . . . . .
                   . . .                                                                                   s-53
                  Start=Ml Stop=M2   ..............                                                        s-54
                  Start Sweep Trigger Auto . . . . . . . . . .                                             s-55
                  Start Sweep Trigger Bus . . . . . . . . . . .                                            s-55
                  Start Sweep Trigger Ext . . . . . . . . . . .                                            S-56
                  Step Control Master . . . . . . . . . . . . .                                            S-56
                  Step Control Slave   .............                                                       S-58
                  Step Dwell . . . . . . . . . . . . . . . . . .                                           s-59
                  Step Points . . . . . . . . . . . . . . . . .                                            S-60
                  StepSize . . . . . . . . . . . . . . . . . .                                             S-60
                  Step Sup Menu . . . . . . . . . . . . . . . .                                            S-61
                  Step Sup PtTrig Auto . . . . . . . . . . . .                                             S-62
                  Step Sup PtTrig Bus . . . . . . . . . . . . .                                            S-62
                  Step Sup PtTrig Ext . . . . . . . . . . . . .                                            S-63
                  ISTOP) . . . . . . . . . . . . . . . . . . . . .                                         S-63
                  SWEEP (MENU). . . . . . . . . . . . . . .
                           . .                                                                             S-64
                  Sweep Mode List . . . . . . . . . . . . . . .                                            S-65
                  Sweep Mode Ramp . . . . . . . . . . . . . . .                                            S-66
                  Sweep Mode Step . . . . . . . . . . . . . . .                                            S-66
                  Sup Span CalAlways  .............                                                        S-67
                  Sup Span CalOnce   ..............                                                        S-67
                  (SWEEP   TIME)   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   S-68
                  SwpTime Auto . . . . . . . . . . . . . . . . .                                           S-68
                  SYSTEM (MENU). . . . . . . . . . . . . . .
                          . .                                                                              S-69



Contents-8
m
1 .

      10 MHz Freq Std Auto            . . . . . . . . . . . .                            T-l
      10 MHz Freq Std Extrnl                  . . . . . . . . . . .                      T-l
      10 MHz Freq Std Intrnl                  . . . . . . . . . . .                      T-2
      10 MHz Freq Std None            . . . . . . . . . . . .                            T-2
      Tracking Menu     . . . . . . . . . . . . . . . .                                  T-3
      TrigOut Delay     . . . . . . . . . . . . . . . .                                  T-3

U.
      Uncoupl Atten     . . . . . . . . . . . . . . . .                                  U-l
      Unlock Info     . . . . . . . . . . . . . . . . .                                  U-l
      Up/Down Power     . . . . . . . . . . . . . . . .                                  u-2
      Up/Dn Size CW     . . . . . . . . . . . . . . . .                                  u-2
      Up/Dn Size Swept      . . . . . . . . . . . . . .                                  u-3
      (USER) . . . .
       . . .                .     .   . . . . . . . . . .
                                          .                                              u-4
                    .
      USER DEFINED (FV1ENU)         . . . . . . . . . . .                                u-4
      VsrKev C l e a r . . . . . . . . . . . . . . . . .
           *                                                                             u-5
      UsrMenu Clear . . . . . . . . . . . . . . . .                                      u-5


      Zero Freq . . . . . . . . . . . . . . . . . .                                       z-1
      Zoom . . . . . . . . . . . . . . . . . . . . .                                      z-1

2a. Error Messages
      Introduction . . . . . . . . . . . . . .                          . . . .          2a-1
      Front Panel Error Messages in Alphabetical                       Order .           2a-1
      SCPI Error Messages in Numerical Order                           . . . . .         2a-5
         Swept CW Generator Specific SCPI Error                         Messages         2a-5
         Universal SCPI Error Messages . . . .                          . . . .          2a-6
           Error Messages From -499 To -400                            . . . . .         2a-6
           Error Messages From -399 To -300                            . . . . .         2a-6
           Error Messages From -299 To -200                            . . . . .         2a-6
           Error Messages From -199 to -100 .                          . . . . .         2a-7

2b. Menu Maps
      ALC Menu . .      . . . .       .   .    .   .   .   .   .   .   .   .   .   .     2b-3
      Frequency Menu    . . . .       .   .    .   .   .   .   .   .   .   .   .   .     2b-5
      Marker Menu .     . . . .       .   .    .   .   .   .   .   .   .   .   .   .     2b-7
      Modulation Menu     . . .       .   .    .   .   .   .   .   .   .   .   .   .     2b-9
      Power Menu . .    . . . .       .   .    .   .   .   .   .   .   .   .   .   .    2b-11
      Service Menu .    . . . .       .   .    .   .   .   .   .   .   .   .   .   .    2b-13
      Sweep Menu . .    . . . .       .   .    .   .   .   .   .   .   .   .   .   .    2b-15
      System Menu .     . . . .       .   .    .   .   .   .   .   .   .   .   .   .    2b-17
      User Cal Menu .   . . . .       .   .    .   .   .   .   .   .   .   .   .   .    2b-19




                                                                                   Contents-9
               2c. Specifications
                   Frequency . . . . . . . . . . . . . . . . . . .       2c-2
                     Range . . . . . . . . . . . . . . . . . . . .       2c-2
                     Resolution . . . . . . . . . . . . . . . . . .      2c-2
                     Frequency Bands (for CW signals) . . . . . . .      2c-2
                     Frequency Modes: . . . . . . . . . . . . . .        2c-2
                     CW and Manual Sweep . . . . . . . . . . . .         2c-2
                     Synthesized Step Sweep . . . . . . . . . . . .      2c-3
                     Synthesized List Mode . . . . . . . . . . . .       2c-3
                     Ramp Sweep Mode . . . . . . . . . . . . . .         2c-3
                     Internal 10 MHz Time Base . . . . . . . . . .       2c-3
                   RF Output . . . . . . . . . . . . . . . . . .         2c-4
                     Output Power . . . . . . . . . . . . . . . .        2c-4
                        Accuracy ( dB)4 . . . . . . . . . . . . . .      2c-5
                        Flatness (dB) . . . . . . . . . . . . . . .      2c-5
                     Analog Power Sweep . . . . . . . . . . . . .        2c-6
                     External Leveling . . . . . . . . . . . . . . .     2c-6
                     Source Match . . . . . . . . . . . . . . . .        2c-6
                   Spectral Purity . . . . . . . . . . . . . . . . .     2c-7
                     Spurious Signals . . . . . . . . . . . . . . .      2c-7
                     Single-Sideband Phase Noise (dBc/Hz) . . . . .      2c-9
                        Offset from Carrier . . . . . . . . . . . . .    2c-9
                     Residual FM (RMS, 50 Hz to 15 kHz bandwidth) .      2c-9
                   General . . . . . . . . . . . . . . . . . . . .      2c-10
                     Environmental . . . . . . . . . . . . . . . .      2c-10
                     Warm-Up Time . . . . . . . . . . . . . . .         2c-10
                     Power Requirements . . . . . . . . . . . . .       2c-10
                     Weight & Dimensions . . . . . . . . . . . . .      2c-10
                     Adapters Supplied . . . . . . . . . . . . . .      2c-10
                     Inputs & Outputs . . . . . . . . . . . . . .       2c-11
                       Auxiliary Output . . . . . . . . . . . . . .     2c-11
                       RF Output . . . . . . . . . . . . . . . .        2c-11
                       External ALC Input . . . . . . . . . . . .       2c-11
                       Trigger Input . . . . . . . . . . . . . . .      2c-11
                       Trigger Output . . . . . . . . . . . . . . .     2c-11
                        10 MHz Reference Input . . . . . . . . . . .    2c-11
                        10 MHz Reference Output . . . . . . . . . .     2c-11
                       Sweep Output . . . . . . . . . . . . . . .       2c-11
                       Stop Sweep Input/Output . . . . . . . . . .      2c-11
                       Z-Axis Blanking/Markers Output . . . . . . .     2c-12
                       Volts/GHz Output . . . . . . . . . . . . .       2c-12
                       Source Module Interface . . . . . . . . . . .    2c-12
                       Auxiliary Interface . . . . . . . . . . . . .    2c-12
                     Models . . . . . . . . . . . . . . . . . . .       2c-12
                     Options . . . . . . . . . . . . . . . . . . .      2c-12
                       Option 001 Add Step Attenuator . . . . . . .     2c-12
                       Option 004 Rear Panel RF Output . . . . . .      2c-12
                       Option 008 1 Hz Frequency Resolution . . . .     2c-12
                       Option 700 MATE System Compatibility . . .       2c-12
                       Option 806 Rack Slide Kit . . . . . . . . . .    2c-13
                       Option 908 Rack Flange Kit . . . . . . . . .     2c-13

Contents- 10
        Option 910 Extra Operating & Service Guides .      2c-13
        Option 013 Rack Flange Kit . . . . . . . . .       2c-13
        Option W30 Two Years Additional Return-To-HP
           Service . . . . . . . . . . . . . . . . .       2c-13

3. Installation
   Initial Inspection . . . . . . . . . . . . . . . .        3-l
   Equipment Supplied . . . . . . . . . . . . . .            3-2
   Options Available . . . . . . . . . . . . . . .           3-2
   Preparation for Use . . . . . . . . . . . . . . .         3-3
      Power Requirements . . . . . . . . . . . . .           3-3
      Line Voltage and Fuse Selection . . . . . . . .        3-3
      Power Cable . . . . . . . . . . . . . . . . .          3-4
     Language Selection . . . . . . . . . . . . . .          3-6
         How to View or Change a Language Selection from
             the Front Panel . . . . . . . . . . . . .       3-6
         How to Select a Language on a Swept CW
             Generator without a Front Panel . . . . .       3-6
      HP-IB Address Selection . . . . . . . . . . .          3-7
         How to View or Change an HP-IB address from
             the Front Panel . . . . . . . . . . . . .       3-8
         How to Prevent a Front Panel Change to an HP-IB
             Address . . . . . . . . . . . . . . . .         3-8
         How to Set the HP-IB Address on a Swept CW
             Generator without a Front Panel . . . . .       3-8
     Mating Connectors . . . . . . . . . . . . . .           3-8
      10 MHz Frequency Reference Selection and Warmup
          Time      . . . . . . . . . . . . . . . . . .      3-8
      Operating Environment . . . . . . . . . . . .          3-9
   Chassis Kits . . . . . . . . . . . . . . . . . .        3-10
     Rack Mount Slide Kit (Option 806) . . . . . . .       3-10
         Installation Procedure . . . . . . . . . . . .    3-11
     Rack Flange Kit for Swept CW Generators with
          Handles Removed (Option 908) . . . . . . .       3-13
         Installation Procedure . . . . . . . . . . . .    3-14
     Rack Flange Kit for Swept CW Generators with
          Handles Attached (Option 913) . . . . . . .      3-15
         Installation Procedure . . . . . . . . . . . .    3-16
   Storage and Shipment . . . . . . . . . . . . . .        3-17
     Environment . . . . . . . . . . . . . . . . .         3-17
     Package the Swept CW Generator for Shipment .         3-18
   Converting HP 8340/41 Systems to HP 8360 L-Series
       Systems . . . . . . . . . . . . . . . . . .          3-19
     Manual Operation . . . . . . . . . . . . . .           3-20
         Compatibility . . . . . . . . . . . . . . .        3-20
         Front Panel Operation . . . . . . . . . . .        3-20
           Instrument Preset Conditions . . . . . . .       3-20
     System Connections . . . . . . . . . . . . .           3-21
         The HP 8510 Network Analyzer . . . . . . .         3-21
         The HP 8757C/E Scalar Network Analyzer . .         3-22


                                                   Contents-l 1
                       The HP 83550 Series Millimeter-wave Source
                           Modules . . . . . . . . . . . . . . .                            3-22
                       The HP 8970B Noise Figure Meter . . . . .                            3-22
                     Remote Operation . . . . . . . . . . . . .                             3-23
                       Language Compatibility . . . . . . . . . .                           3-23
                       Network Analyzer Language . . . . . . . .                            3-23
                       Test and Measurement System Language . .                             3-23
                       Control Interface Intermediate Language . .                          3-23
                     Converting from Network Analyzer Language to
                        SCPI . . . . . . . . . . . . . . . . .                              3-23
                       Numeric Suffixes . . . . . . . . . . . . .                           3-24
                       Status Bytes . . . . . . . . . . . . . . .                           3-24

              4.   Operator's Check and Routine Maintenance
                   Operator's Checks . . . . . . .     .    .    .   .   .   .    .     .    4-l
                     Service Information . . . . . .   .    .    .   .   .   .    .     .    4-l
                   Local Operator's Check . . . . .    .    .    .   .   .   .     .    .    4-2
                     Description . . . . . . . . .     .    .    .   .   .   .    .    .     4-2
                     Preliminary Check . . . . . .     .    .    .   .   .   .    .    .     4-2
                     Main Check . . . . . . . . .      .    .    .   .   .   .    .    .     4-3
                   Routine Maintenance . . . . . .     .    .    .   .   .   .    .     .    4-4
                     How to Replace the Line Fuse .     .   .    .   .   .   .    .    .     4-4
                     How to Clean the Fan Filter . .   .    .    .   .   .   .    .    .     4-5
                     How to Clean the Cabinet . . .    .    .    .   .   .    .    .    .    4-6
                     How to Clean the Display Filter    .    .   .   .   .   .    .    .     4-6

              5. Instrument History

                   Index




Contents-12
Figures
            O-l. Typical Serial Number Label . . . . . . . . . .        vii
            l-l. The HP 8360 L-Series Swept CW Generator . . .         l-3
            l-2. Display . . . . . . . . . . . . . . . . . . .         1-4
            l-3. Entry Area . . . . . . . . . . . . . . . . .          1-5
            l-4. CW Operation and Start/Stop Frequency Sweep .         1-7
            l-5. Center Frequency and Span Operation . . . . .         1-9
            l-6. Power Level and Sweep Time Operation . . . . .      l-11
            l-7. Continuous, Single, and Manual Sweep Operation      l-13
            l-8. Marker Operation . . . . . . . . . . . . . .        1-15
            l-9. Saving and Recalling an Instrument State . . . .    1-17
          l-10. Power Sweep and Power Slope Operation . . . .        1-19
          l-11. ALC Circuit Externally Leveled . . . . . . . .       l-23
          1-12. Typical Diode Detector Response at 25



◦ Jabse Service Manual Search 2024 ◦ Jabse PravopisonTap.bg ◦ Other service manual resources online : FixyaeServiceinfo