Service Manuals, User Guides, Schematic Diagrams or docs for : Agilent 33500 Series Waveform Generators - Using the Built-in Web Interface 5991-1132EN c20121024 [4]

<< Back | Home

Most service manuals and schematics are PDF files, so You will need Adobre Acrobat Reader to view : Acrobat Download Some of the files are DjVu format. Readers and resources available here : DjVu Resources
For the compressed files, most common are zip and rar. Please, extract files with Your favorite compression software ( WinZip, WinRAR ... ) before viewing. If a document has multiple parts, You should download all, before extracting.
Good luck. Repair on Your own risk. Make sure You know what You are doing.




Image preview - the first page of the document
33500 Series Waveform Generators - Using the Built-in Web Interface 5991-1132EN c20121024 [4]


>> Download 33500 Series Waveform Generators - Using the Built-in Web Interface 5991-1132EN c20121024 [4] documenatation <<

Text preview - extract from the document
                                         Agilent 33500 Series
                                         Waveform Generators:
                                         Using the Built-in Web Interface
                                         Technical Overview



The Agilent 33500 Series waveform generators include a       instrument's built-in Web interface. The Web interface also
front panel that allows you to configure and control the     provides a convenient way to learn the SCPI programming
instrument quickly and easily. When you are not physically   language.
near the instrument, you may control the instrument via
the Standard Commands for Programmable Instruments           To begin using the Web interface, simply connect your
(SCPI) programming language.                                 waveform generator to the LAN and enter the instrument's
                                                             IP address into your computer's Web browser. To find the
But what if you are not near the instrument and you are      instrument's IP address, look at the lower left corner of the
not a SCPI expert? Or suppose you are a SCPI expert,         screen during boot-up, or press [System] > [I/O Config]
but you want to take advantage of your computer's large      > [LAN Settings] on the front panel.
screen to control the instrument and view its configura-
tion. Perhaps you are on a business trip or working from     After you enter the IP address into your browser, you will
home and you want to control and monitor your instru-        see the Web interface's main screen, as shown in Figure 1.
ment. For these situations and more, the answer is the

                                                                                             Figure 1. Main screen for
                                                                                             a Web-enabled 33522B
                                                                                             waveform generator
In some network configurations, a proxy server may                    Configuring and Controlling Your Instrument via
prevent access to the instrument ("Page cannot be                     the LAN
displayed"). In this situation, the proxy must be configured
from the browser such that the proxy is not used for IP               Use the control tab on the Web interface to configure and
addresses within the range of those that can be assigned              control your waveform generator.
to the instrument.
                                                                      The typical use model for this page is described below. The
When your waveform generator is connected to the LAN,                 numbers correspond to the numbers shown in Figure 3.
you will see four small tabs on the upper left side of the
screen, as shown in Figure 2.                                         1. Select a radio button to indicate whether you want to
                                                                         configure Channel 1 or Channel 2.
           Home       Displays basic information about the
                                                                      2. Press a button to indicate whether you want to config-
                      instrument and its LAN connection
                                                                         ure parameters relating to the waveform, modulation,
           Control    Allows you to configure and operate the            sweep, burst, or output.
                      instrument
           LAN        Allows you to configure the instrument          3. Configure the parameters relevant to the channel and
                      for the LAN                                        the button selected in steps 1 and 2, above.
           Help       Displays help on using the Web interface        4. Press Apply to apply the saved parameters to the instru-
                                                                         ment, or press Undo Changes to undo the changes that
Figure 2. The four tabs on a Web-enabled waveform generator              you made to the parameters on the screen.
and their functions
                                                                      If you attempt to choose a different button in area 1 or 2
                                                                      before you have applied your changes to the instrument,
                                                                      the Web interface will issue the reminder shown in
                                                                      Figure 4.




                                                                                          Figure 4. The Web interface will remind
                                                                                          you to apply your changes if you neglect to
                                                                                          do so before you choose a different button.




Figure 3. Pressing the control tab brings you to a screen where you can configure your
waveform generator.




2
Figure 5. The Command Monitor button is in the upper right corner of the Control window.


Learn SCPI Commands Using Command Monitor                                                  Figure 6. The
                                                                                           Command tab lists the
                                                                                           SCPI commands that
The Web interface includes a command monitor that                                          have been sent to the
helps you learn the instrument's SCPI language. To use                                     instrument based on
this feature, simply press the Command Monitor button in                                   your selections in the
the upper right corner of the Control window, as shown in                                  Control tab.
Figure 5.

The command monitor opens with the Command History
tab selected. This tab lists the commands that have been
sent to the instrument from the Control tab, as shown in
Figure 6. As the Web interface logs the SCPI commands
related to changes made to the instrument's configuration,
you can learn the SCPI language and copy commands into
your programming environment as desired.

The second tab in the Command Monitor window is
Current Configuration. This tab shows all of the commands
that put the instrument in its current state, as shown in
Figure 7. Note that this list includes the commands for the
instrument's default power-on configuration, so this list
may be substantially longer than the list in the Command
History tab.
                                                                                           Figure 7. The Current
                                                                                           Configuration tab
                                                                                           shows the entire
                                                                                           list of commands
Summary                                                                                    that put the instru-
                                                                                           ment in its current
The 33500 Series Web interface is a powerful and easy-to-                                  state, including the
use tool that allows you to easily control the instrument                                  commands for the
remotely. You can use the Web interface to configure the                                   power-on sequence.
instrument and monitor its operation. As you interact
with your instrument via the interface, you can use
the Command Monitor to learn the SCPI programming
language.




                                                                                                              3
                                                                    www.agilent.com
                                                                    www.agilent.com/find/trueform

                                                                    For more information on Agilent Technologies' products,
 Agilent Advantage Services is committed to your success
                                                                    applications or services, please contact your local Agilent office.
 throughout your equipment's lifetime. To keep you competi-         The complete list is available at:
 tive, we continually invest in tools and processes that
                                                                    www.agilent.com/find/contactus
 speed up calibration and repair and reduce your cost of
 ownership. You can also use Infoline Web Services to man-
                                                                    Americas
 age equipment and services more effectively. By sharing
                                                                    Canada                            (877) 894 4414
 our measurement and service expertise, we help you create
                                                                    Brazil                            (11) 4197 3600
 the products that change our world.                                Mexico                            01800 5064 800
                                                                    United States                     (800) 829 4444
          www.agilent.com/find/advantageservices

                    Agilent Electronic Measurement Group
                                                                    Asia Pacific
                   DEKRA Certified                                  Australia                         1 800 629 485
                   ISO 9001:2008        Quality Management Sys
                                                           System
                                                                    China                             800 810 0189
                                                                    Hong Kong                         800 938 693
                www.agilent.com/quality
                                                                    India                             1 800 112 929
                                                                    Japan                             0120 (421) 345
                                                                    Korea                             080 769 0800
    Agilent Email Updates                                           Malaysia                          1 800 888 848
www.agilent.com/find/emailupdates                                   Singapore                         1 800 375 8100
Get the latest information on the products and                      Taiwan                            0800 047 866
applications you select.                                            Other AP Countries                (65) 375 8100

                                                                    Europe & Middle East
                                                                    Belgium                           32 (0) 2 404 93 40
www.axiestandard.org                                                Denmark                           45 45 80 12 15
AdvancedTCA



◦ Jabse Service Manual Search 2024 ◦ Jabse PravopisonTap.bg ◦ Other service manual resources online : FixyaeServiceinfo