DS1230AB-DS1230Y


>> Download DS1230AB-DS1230Y documenatation <<

Text preview - extract from the document
19-5635; Rev 11/10



                                                                             DS1230Y/AB
                                                                    256k Nonvolatile SRAM
www.maxim-ic.com


FEATURES                                               PIN ASSIGNMENT
   10 years minimum data retention in the                            A14     1               28   VCC
   absence of external power                                         A12     2               27   WE
   Data is automatically protected during power                       A7     3               26   A13
                                                                      A6     4               25   A8
   loss                                                               A5     5               24   A9
   Replaces 32k x 8 volatile static RAM,                              A4     6               23   A11
   EEPROM or Flash memory                                             A3     7               22   OE
   Unlimited write cycles                                             A2     8               21   A10
                                                                      A1     9               20   CE
   Low-power CMOS                                                     A0     10              19   DQ7
   Read and write access times of 70 ns                              DQ0     11              18   DQ6
   Lithium energy source is electrically                             DQ1
                                                                             12              17
                                                                                                  DQ5
                                                                             13              16
   disconnected to retain freshness until power is                   DQ2                          DQ4
                                                                     GND     14              15   DQ3
   applied for the first time