Service Manuals, User Guides, Schematic Diagrams or docs for : Agilent 5989-7976EN N7744A N7745A Optical Multiport Power Meter - Data Sheet c20140715 [7]

<< Back | Home

Most service manuals and schematics are PDF files, so You will need Adobre Acrobat Reader to view : Acrobat Download Some of the files are DjVu format. Readers and resources available here : DjVu Resources
For the compressed files, most common are zip and rar. Please, extract files with Your favorite compression software ( WinZip, WinRAR ... ) before viewing. If a document has multiple parts, You should download all, before extracting.
Good luck. Repair on Your own risk. Make sure You know what You are doing.




Image preview - the first page of the document
5989-7976EN N7744A N7745A Optical Multiport Power Meter - Data Sheet c20140715 [7]


>> Download 5989-7976EN N7744A N7745A Optical Multiport Power Meter - Data Sheet c20140715 [7] documenatation <<

Text preview - extract from the document
Keysight Technologies
N7744A 4-Channel Optical Multiport
Power Meter
N7745A 8-Channel Optical Multiport
Power Meter


                                     Data Sheet
02 | Keysight | N7744A 4-Channel Optical Multiport Power Meter N7745A 8-Channel Optical Multiport Power Meter - Data Sheet



        General Information


        Up to 8 power meter channels in a small                                       A reliable four-port optical connection with
        package                                                                       the new one click quad-adapter
        Keysight Technologies, Inc. new N7744A and N7745A                             With this new power meter comes the unprecedented
        optical power meters with four or eight power-sensor                          N7740 fiber connectivity concept, which is a quadruple
        channels provide manufacturing customers with increased                       adapter with a snap-on quick-locking mechanism. The
        throughput and operational efficiency to meet today's chal-                   device to be tested can be connected to the quad-adapters
        lenges in manufacturing.                                                      in a comfortable ergonomic working position, even while
                                                                                      the instrument is measuring another device.

        Designed for optical multiport applications                                   The quad-adapters can be quickly snapped on to the instru-
                                                                                      ment, to provide reliable and repeatable high-precision
        Designed for characterizing optical multiport components,                     connections. Use of the quad-adapters simplifies aligning
        these optical power meters offer industry-leading solutions                   connector keys, especially for rack-mounted instruments
        for device connectivity, high-speed measurement data                          and makes it easier to connect ports in the desired order,
        acquisition and fast data transfer for postprocessing. The                    helping to avoid errors and connector damage.
        multiport power meter enables fast measurement solu-
        tions for all multiport devices; for example multiplexers,                    This quad-adapter also fits into Keysight's standard bare
        PON splitters, wavelength selective switches (WSS) and                        fiber connectivity solutions 81000BI. The one click zeroing
        ROADMs, as well as compact setups for simultaneous                            adapter N7740ZI allows quick and reliable 4-port zeroing of
        testing of multiple single-port devices.                                      the new power meters.


        Save significant rack space                                                   Code compatible with your existing Keysight
        These power meters achieve a level of space-saving                            optical power meters
        channel density that is new in the industry, and simplify
                                                                                      The new optical multiport power meter is code compatible
        fiber handling for many-port device testing. This is comple-
                                                                                      with the Keysight optical power meter sensors and optical
        mented by the ease of integrating multiple instruments
                                                                                      power meter heads. Simply replace up to eight existing
        into a single setup with LAN or USB connections.
                                                                                      single power meter modules with the new N7745A optical
                                                                                      multiport power meter, adapt the new instrument configu-
        A single N7744A/45A is only one rack unit high and a half
                                                                                      ration and run your existing application software.
        rack unit wide.
03 | Keysight | N7744A 4-Channel Optical Multiport Power Meter N7745A 8-Channel Optical Multiport Power Meter - Data Sheet



        Key benefits                                                                  Definitions
        10x faster than previous swept-wavelength                                     Generally, all specifications are valid at the stated
                                                                                      operating and measurement conditions and settings, with
        measurement solutions                                                         uninterrupted line voltage.
          