Service Manuals, User Guides, Schematic Diagrams or docs for : Agilent 5991-4594EN Power-Consumption Measurements for LTE User Equipment - Application Note c20141007 [8]

<< Back | Home

Most service manuals and schematics are PDF files, so You will need Adobre Acrobat Reader to view : Acrobat Download Some of the files are DjVu format. Readers and resources available here : DjVu Resources
For the compressed files, most common are zip and rar. Please, extract files with Your favorite compression software ( WinZip, WinRAR ... ) before viewing. If a document has multiple parts, You should download all, before extracting.
Good luck. Repair on Your own risk. Make sure You know what You are doing.




Image preview - the first page of the document
5991-4594EN Power-Consumption Measurements for LTE User Equipment - Application Note c20141007 [8]


>> Download 5991-4594EN Power-Consumption Measurements for LTE User Equipment - Application Note c20141007 [8] documenatation <<

Text preview - extract from the document
Keysight Technologies
Power-Consumption Measurements
for LTE User Equipment




       Application Note




       If you are designing smartphone chipsets or operating a mobile
       network, you need to determine how certain parameters affect a
       speciic smartphone's power consumption and igure out how to
       adjust the parameters to improve battery life. In this application
       note we show how to use the Keysight Technologies, Inc. E6621A
       PXT wireless communications test set and the Keysight N6705B
       DC power analyzer to establish a power consumption model for
       LTE user equipment (UE). The model is useful when you need to
       examine the UE battery life in system-level simulations.

       We will explain how the Keysight equipment can be used in
       manual tests, but we do not discuss how to make automated
       tests (for example, using VEE software).

       In this application note, we analyze smartphones adhering to the
       3GPP LTE standard [1].
Introduction

     Modern smartphones have limited battery life, and this affects user satisfaction. Chipset manufac-
     turers and mobile network operators will want to evaluate a smartphones' power consumption in a
     realistic setup and establish a power consumption model based on the evaluation. The model helps
     you determine how certain parameters affect a speciic smartphone's power consumption and how
     you can adjust the parameters to improve battery life.

     The key parameters are uplink (UL) and downlink (DL) data rates (R), transmit (Tx) and receive (Rx)
     power levels (S), cell bandwidth (BW), and discontinuous reception (DRX). The parameters affect
     the smartphone's modem, and more speciically, the Rx and Tx base band (BB) and Rx and Tx radio
     frequency (RF) components. A power consumption model that includes these components has been
     proposed in an article entitled Empirical LTE Smartphone Power Model with DRX Operation for Sys-
     tem Level Simulations [2]. It covers the contribution from each parameter on the related component,
     as illustrated in Figure 1.




     Figure 1. UE power consumption model, based on Figure 1 in [2]




     The model is made by measuring how each parameter affects the power consumption, but the
     model does so by capturing major trends and not implementation-speciic peculiarities.
03 | Keysight | Power-Consumption Measurements for LTE User Equipment - Application Note



Setup description                                                                    Proposed list of measurements
The measurements were performed in the laboratory using                              The goal is to estimate how the Rx and Tx BB and RF components
the Keysight E6621A PXT wireless communications test set                             contribute to the total modem power consumption. This goal is
[3] and the N6705B DC power analyzer [4] with the N6781A                             achieved by varying one key parameter, for example DL data rate
2-quadrant source/measure unit [5] module installed.                                 for Rx BB examination, while keeping other parameters constant.
                                                                                     Table 1 contains the test cases. The varied parameter of each test
The UE is connected to                                                               is marked with brackets.
 



◦ Jabse Service Manual Search 2024 ◦ Jabse PravopisonTap.bg ◦ Other service manual resources online : FixyaeServiceinfo