Service Manuals, User Guides, Schematic Diagrams or docs for : Agilent 5991-3616EN ENA Series Network Analyzer - Configuration Guide c20140728 [6]

<< Back | Home

Most service manuals and schematics are PDF files, so You will need Adobre Acrobat Reader to view : Acrobat Download Some of the files are DjVu format. Readers and resources available here : DjVu Resources
For the compressed files, most common are zip and rar. Please, extract files with Your favorite compression software ( WinZip, WinRAR ... ) before viewing. If a document has multiple parts, You should download all, before extracting.
Good luck. Repair on Your own risk. Make sure You know what You are doing.




Image preview - the first page of the document
5991-3616EN ENA Series Network Analyzer - Configuration Guide c20140728 [6]


>> Download 5991-3616EN ENA Series Network Analyzer - Configuration Guide c20140728 [6] documenatation <<

Text preview - extract from the document
Keysight E5063A
ENA Series Network Analyzer
100 kHz to 4.5/8.5/18 GHz




                              Configuration Guide
Ordering Guide

The following steps will guide you through configuring your Keysight Technologies' E5063A.

Standard furnished item
 Description                                      Additional Information
 Installation guide                               Contains the information necessary to start up with the E5063A.
 CD ROM IO libraries
 Power Cable
 Calibration of Certification


Step 1. Choose frequency option (must choose one of the three frequency options.)
 Description                                                                                                                   Option No.
 Network Analyzer 100 kHz to 4.5 GHz, S-parameter test set, 50  system impedance                                               E5063A-245
 Network Analyzer 100 kHz to 8.5 GHz, S-parameter test set, 50  system impedance                                               E5063A-285
 Network Analyzer 100 kHz to 18 GHz, S-parameter test set, 50  system impedance                                                E5063A-2H5


Step 2. Choose software option (If not required, go to step 3.)
 Description                        Option No.         Requires        Not Compatible        Additional Information
 Time Domain/Test wizard            E5063A-011         None            None                  This option is required for time domain analysis or PCB
                                                                                             measurements.




Step 3. Choose storage drive option (mandatory option)
 Description                        Option No.         Requires        Not Compatible        Additional Information
 Standard storage drive             E5061B-019         None            None                  Option 019 is the only storage drive option for the E5063A.
                                                                                             Must choose this option




Step 4. Add accessory option (If not required, go to step 5.)
 Description                      Option No.         Requires        Not Compatible      Additional Information
 Keyboard                         E5063A-810         None            None                USB Keyboard for simplifying word inputs.
 Mouse                            E5063A-820         None            None                USB Mouse for simplifying measurement operation.
 Rackmount Kit                    E5063A-1CM         None            None                Not installable simultaneously with E5063A -1CP.
 Front Handle Kit                 E5063A-1CN         None            None                Not installable simultaneously with E5063A -1CP.
 Handle/Rack Mount Kit            E5063A-1CP         None            None                Not installable simultaneously with E5063A -1CM or 1CN.




Step 5. Add calibration certificate (If not required, go to step 6.)
 Description                                       Option No.               Additional Information
 ISO 17025 Compliant Calibration                   E5063A-1A7               ISO 17025 compliant calibration
 ANSI Z540 compliant calibration                   E5063A-A6J               ANSI Z540 compliant calibration




                                                                              2
Step 6. Choose warranty plan
3 year return-to-keysight warranty and service is standard. The extended warranty option is available. Contact your local Keysight office or visit our web site for
more information.

Step 7. Add related products
 Description                          Option No.          Requires        Not Compatible        Additional Information
 USB Coaxial Switch, DC to 18         U1810B              None            None                  The number of test ports can be expanded up to four by
 GHz, SPDT                                                                                      connecting this SPDT switch to the E5063A's port-1 and 2.
                                                                                                  