Service Manuals, User Guides, Schematic Diagrams or docs for : Agilent Capacitance Method_252CFlat Plate_252C Liquid_252C Gel_252C Ultra Thin Film_252C Compound Film_252CDielectric Constant and D 5991-1843EN c20130129 [2]

<< Back | Home

Most service manuals and schematics are PDF files, so You will need Adobre Acrobat Reader to view : Acrobat Download Some of the files are DjVu format. Readers and resources available here : DjVu Resources
For the compressed files, most common are zip and rar. Please, extract files with Your favorite compression software ( WinZip, WinRAR ... ) before viewing. If a document has multiple parts, You should download all, before extracting.
Good luck. Repair on Your own risk. Make sure You know what You are doing.




Image preview - the first page of the document
Capacitance Method_252CFlat Plate_252C Liquid_252C Gel_252C Ultra Thin Film_252C Compound Film_252CDielectric Constant and D 5991-1843EN c20130129 [2]


>> Download Capacitance Method_252CFlat Plate_252C Liquid_252C Gel_252C Ultra Thin Film_252C Compound Film_252CDielectric Constant and D 5991-1843EN c20130129 [2] documenatation <<

Text preview - extract from the document
                                         Capacitance Method,
                                         Flat Plate, Liquid, Gel, Ultra Thin Film, Compound Film,
                                         Dielectric Constant and Dielectric Loss Tangent
                                         Measurement System
                                                                                                System No. DPS17
                                         Agilent Technologies and KEYCOM Corp.


                                                                                         Specifications
                                                                                          when used with E4980A
                                                                                         Frequency 20Hz ~ 2MHz
                                                                                         Permittivity 1.05 ~ 1000
                                                                                                       Accuracy : 3%
                                                                                         tan 0.001~0.1
                                                                                                 Accuracy : 5%
                                                                                         Measurement Process
                                                                                         1. Connect coaxial cables of the
                                                                                            electrode to your E4980A.
                                                                                         2. Bring the high and low elec-
                                                                                            trodes at the end of the coaxial
                                                                                            cables into contact with each
                                                                                            other to execute short calibra-
                                                                                            tion, and separate the two to
             E4980A Precision LCR Meter and DPT-009 for sheet, liquid, gel
                                                                                            execute open calibration.

Ideal solution for r'/tan measurement of sheet,                                          3. Insert specimen between elec-
                                                                                            trodes and start measurement.
thin film, multi-layer thin film, liquid and gel
 ASTM, JIS Standard compliant                Features                                  Specimen examples
KEYCOM offers variety of highly accu-           DPT-009 : allows you to measure         Prepreg
rate measurement systems for dielectric         samples of approx. 50 m ~ 2mm in        Semiconductor wafer
constant and dielectric loss tangent            thickness simply and easily, without    Thin film on wafer
measurement of flat plane, liquid, or gel.      your having to pasting or sputtering    PCB
Temperature characteristics measurement         electrodes to the sample.               Grease
options between-70 C and +30 C are also         DPT-2141: allows you to measure         Water
available. Your Windows PC with the             approx. 50 m ~ 2mm in thickness in      Fruit
software controls your E4980A Precision         conformity to the JIS Standard.
LCR Meter and thermostat/humidistat             Supports temperature characteris-
chamber, automating time-consuming              tics measurement between -70 C
temperature/humidity characteristics            and +300 C.
measurements.                                   Automatic measurement by PC.

Compliance standards                         Applications
ASTM D-150, JIS C2101, JIS C2141,               Material property evaluation for
JIS K6911                                       electronic components
                                                Semiconductor property evaluation
                                                Material deterioration evaluation
                                                Chemical property evaluation
         Capacitance Method,
         Dielectric Constant and Dielectric Loss Tangent Measurement System




                 DPT-080 for sheet                                             DPT-2141 for sheet, plate
                                                                                JIS-C2141 compliant




                                                                                                                                  www.keycom.co.jp
                                                                                                                                  For more information on KEYCOM
                                                                                                                                  Corp. products, applications or
                                                                                                                                  services, please visit our website at
           DPT-013 for liquid, powder                                                                                             www.keycom.co.jp or e-mail us at
                                                                                                                                  E-mail: [email protected]
                                                                                 Measurement window
                                                                                                                                  KEYCOM Corp.
                                                                                                                                  3-40-2 Minamiotsuka Toshima-ku, Tokyo
                                                                                                                                  170-0005 Japan
Ordering Information                                                                                                              Phone: +81-3-5950-3101
                                                                                                                                  FAX: +81-3-5950-3380
Agilent Technologies
                                                                                                                                  KEYCOM USA Corp.
E4980A Precision LCR Meter
                                                                                                                                  533 Airport Blvd. Suite 400 Burlingame,
                                                                                                                                  CA 94010 USA
KEYCOM Corp.                                                                                                                      Phone: +1-650-685-2477
                                                                                                                                  FAX: +1-650-373-2002
System No. DPS17
1. Measurement electrode                                                                                                          www.agilent.com
   20Hz 



◦ Jabse Service Manual Search 2024 ◦ Jabse PravopisonTap.bg ◦ Other service manual resources online : FixyaeServiceinfo