                    COPYRIGHT AND DISCLAIMER NOTICE

Copyright - Agilent Technologies, Inc. Reproduced with the permission of Agilent
Technologies Inc. Agilent Technologies, Inc. makes no warranty of any kind with regard
to this material including, but not limited to, the implied warranties of merchantability
and fitness for a particular purpose. Agilent Technologies, Inc. is not liable for errors
contained herein or for incidental or consequential damages in connection with the
furnishing, performance, or use of this material or data.
HP'S NEW TIME INTERVAL MEASUREMENT                                                SOLUTION

The HP 1726A Time [nterval Oscilloscope is a new time interval measuring instrument. Time interval counter            (
and oscilloscope technologies    have been synergistically combined in the 1726A to offer performance,
convenience,    and value unmatched   by alternative instrumentation.   The contributions of the Time Interval
Oscilloscope benefit users with frequently encountered      timing applications and/or precise timing
measurement     requirements.

The requirement   for stringent timing measurements has resulted from advances in IC design, device
characterization of custom integrated circuits (e.g., bipolar and MO5 processes), ECL circuits, and faster
clock speeds in computers and other electronic systems. For example, characterizing a'process, verifying
system operation, or troubleshooting   a new design all require highly accurate and repeatable measurements.
The feature set of the 1726A provides advanced performance      with simple setup and the front panel
conveniences expected from Hewlett-Packard      products,

"THE COMPLETE TIME
INTERVAL SOLUTION"
Completing     the time interval
$olution i$ the I-IF' 10326A Time
Interval Standard, a dual channel
signal source. The 10326A's
waveform period accuracy (+/-5
picoseconds) and specified dual-
channel timing relationships
provide convenient      signals with
which to evaluate system
performance      and subsystem
design. The 10326A is
exceptionally    easy to maintain,                                                                                         -.
and its calibration procedure is
completely traceable to the
United States National Bureau of
Standards and to the calibration
facilities of other International
Standards Organization
members.

FAST, CONFIDENT                         the Main Time/Div switch, allows      independent     of the operator's
                                        the 1726A to make precise             skill level. The fast mode, which
MEASUREMENTS                            measurements on virtually any         reduces the,number      of averages
Combining a CRT with a marker           repetitive signal that can be         taken by a factor of ten,
system makes the measured               displayed on an oscilloscope. A       minimizes measurement       time in
interval easy to identify. Matched      crystal-referenced   time base        all operating modes. In
wideband pre-amplifiers     allow       combines with sophisticated           production and record-keeping
pulse parameters such as                triggering circuits to form the       ap'plications, a standard HP-IB
overshoot and ringing to be             most accurate measurement             interface outputs time interval
examined, and the overlap mode          system available today-up     to 10   information.
permits precise measurements      to    picosecond resolution and 50
be made from specific points on         picosecond accuracy.                  TWO INSTRUMENTS              IN ONE
any displayed waveform. This
                                                                              The feature set of the 1726A
measurement     system eliminates       REPEATABILITY AND                     Time Interval Oscilloscope
uncertainty concerning the exact        CONVENIENCE                           provides the performance      of two
interval being measured, and it
                                        Complex time interval                 complete instruments. Not only
obsoletes the technique of
                                        measurements are highly               is the 1726A the most advanced
externally gating a time interval
                                        repeatable and easy to make with      time interval measurement
counter with an oscilloscope.
                                        the 1726A's triggered mode of         solution, but with its time
                                        operation. The triggered mode         interval module turned off, the
PRECISE MEASUREMENTS                                                          1726A offers all the capabilities of   f,-
                                        minimizes setup time, simplifies
(+/-50 PICOSECONDS)                     measurement procedures, and it        a general purpose, 275 MHz
Time interval   averaging,   which is   allows highly repeatable              oscilloscope.
automatically   controlled   through    measurements to be obtained