Text preview - extract from the document
        Agilent E361XA 30W BENCH SERIES DC POWER SUPPLIES



               OPERATING AND SERVICE MANUAL FOR MODELS:

                                             Agilent E3610A
                                             Agilent E3611A
                                             Agilent E3612A


                                            6CDNG QH %QPVGPVU

                            5#('6; 57//#4;                       
                            )'0'4#. +0(14/#6+10                  
                            &GUETKRVKQP                          
                            5RGEKHKECVKQPU CPF %JCTCEVGTKUVKEU   
                            1RVKQPU                              
                            +PUVTWOGPVU +FGPVKHKECVKQP           
                            +056#..#6+10                         
                            +PURGEVKQP                           
                            .QECVKQP CPF %QQNKPI                 
                            +PRWV 2QYGT 4GSWKTGOGPVU             
                            2QYGT %QTF                           
                            12'4#6+10                            
                            6WTP1P %JGEMQWV 2TQEGFWTG            
                            %QPUVCPV 8QNVCIG 1RGTCVKQP           
                            %QPUVCPV %WTTGPV 1RGTCVKQP           
                            %QPPGEVKPI .QCFU                     
                            1RGTCVKQP $G[QPF 4CVGF 1WVRWV        
                            2WNUG .QCFKPI                        
                            %CRCEKVKXG .QCFU                     
                            4GXGTUG %WTTGPV .QCFKPI              
                            5'48+%' +0(14/#6+10                  #




Manual Part No. 5959-5304                                            April 2000
                                                                      Edition 5



                                                           1-1
SAFETY SUMMARY                                                           KEEP AWAY FROM LIVE CIRCUITS.
                                                                         Operating personnel must not remove instrument covers.
                                                                         Component replacement and internal adjustments must be
The following general safety precautions must be observed                made by qualified service personnel. Do not replace compo-
during all phases of operation, service, and repair of this              nents with power cable connected. Under certain conditions,
instrument. Failure to comply with these precautions or with             dangerous voltages may exist even with the power cable
specific warnings elsewhere in this manual violates safety               removed. To avoid injuries, always disconnect power, dis-
standards of design, manufacture, and intended use of the                charge circuits and remove external voltage sources before
instrument. Agilent Technologies assumes no liability for the            touching components.
customer's failure to comply with these requirements.
                                                                         SAFETY SYMBOLS
Before Applying Power                                                                                Instruction manual symbol; the
Verify that the product is set to match the available line
                                                                                                     product will be marked with this
voltage.
                                                                             !                       symbol when it is necessary for
                                                                                                     the user to refer to the instruction
Ground The Instrument.                                                                               manual.
This product is a Safety Class I instrument (provided with a
protective earth terminal). To minimize shock hazard, the
instrument chassis and cabinet must be connected to an                           or                  Indicate earth(ground) terminal.
electrical ground. The instrument must be connected to the
ac power supply mains through a three-conductor power
cable, with the third wire firmly connected to an electrical                                         The WARNING sign denotes a
                                                                          WARNING
                                                                                                     hazard. It calls attention to a proce-
ground (safety ground) at the power outlet. Any interruption of
                                                                                                     dure, practice, or the like, which, if
the protective(grounding) conductor or disconnection of the
                                                                                                     not correctly performed or adhered
protective earth terminal will cause a potential shock hazard                                        to, could result in personal injury.
that could result in personal injury. If the instrument is to be                                     Do not proceed beyond a WARN-
energized via an external autotransformer for voltage reduc-                                         ING sign until the indicated con-
tion, be certain that the autotransformer common terminal is                                         ditions are fully understood and
connected to the neutral (earthed pole) of the ac power lines                                        met.
(supply mains).
                                                                          CAUTION                    The CAUTION sign denotes a haz-
Do Not Operate In An Explosive Atmosphere                                                            ard. It calls attention to an operating
                                                                                                     procedure, or the like, which, if not
Do not operate the instrument in the presence of flammable
                                                                                                     correctly performed or adhered to,
gases or fumes.
                                                                                                     could result in damage to or destruc-
                                                                                                     tion of part or all of the product. Do
Regulatory Information for Canada                                                                    not proceed beyond CAUTION sign
This ISM device complies with Canadian ICES-001.                                                     until the indicated conditions are fully
Cet appareil ISM est conforme 