Service Manuals, User Guides, Schematic Diagrams or docs for : Daewoo Air Conditioning DAEWOO+180C

<< Back | Home

Most service manuals and schematics are PDF files, so You will need Adobre Acrobat Reader to view : Acrobat Download Some of the files are DjVu format. Readers and resources available here : DjVu Resources
For the compressed files, most common are zip and rar. Please, extract files with Your favorite compression software ( WinZip, WinRAR ... ) before viewing. If a document has multiple parts, You should download all, before extracting.
Good luck. Repair on Your own risk. Make sure You know what You are doing.




Image preview - the first page of the document
DAEWOO+180C


>> Download DAEWOO+180C documenatation <<

Text preview - extract from the document
TABLE OF CONTENTS
1. PRECAUTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2


2. GENERAL SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3


3. NAMES OF MAJOR COMPONENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4


4. FUNCTION OF MAIN COMPONENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5


5. GENERAL INFORMATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6


6. CARE AND MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7


7. TROUBLE SHOOTING GUIDE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8


8. HOW TO DISASSEMBLE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10


9. WIRING DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11


10. REFRIGERANT CYCLE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12


11. EXPLODED DIAGRAM AND PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13




                                                                                      1
1. PRECAUTION
Please observe the following instructions.

1. Turn off unit.
  Make sure the unit is OFF and the AC cord is unplugged before repairing or servicing.


2. In case of checking the circuit unavoidably while the unit is connected with power source, be careful
   not to connect with the part of electric charge.
  You may cause electric shock.


3. Use of proper part if you need to replace the part, be sure to use genuine part of servicing model.
  Do not repair or replace the electric contact part.
  Consumer must not repair the unit, because it is dangerous.


4. Use of proper tool.
  You must use the proper tool to repair the unit, and use the measuring appliance adjusted accurately.


5. Damage of electric wire and power cord when servicing.
  Check electric wire and a surely replace a damage electric wire and a damage power cord.


6. Never use connecting the middle of wire, after cutting the middle of wire.
  It may cause a fire and trouble.


7. Checking the insulation resistance.
  After you complete the assembly of unit, surely check the insulation resistance.
  Confirm that the insulation resistance of the power line and the ground terminal is over 30M by measuring insulation
  resistance.


8. Checking the ground.
  After checking the ground, servicing it completely.


9. Checking the installation.
  After checking the installation, servicing it completely.


10. Care children.
   When servicing, do not make the children approach the air-conditioner.




                                                              2
2. GENERAL SPECIFICATIONS

                                               MODEL
                                                           DWA-180C
 ITEM

 Power Source              V/Hz                           AC 220V/60Hz

                           Btu/h                             17,500
 Cooling Capacity
                           Kcal/h                             4,410
                           Btu/wh                              9.0
 Energy Efficiency Ratio
                           Kcal/wh                             2.3

 Dehumidification          L/h                                 2.0

                           Power Input(W)                     1,900
 Electrical Data
                           Running Current(A)                  9.0

                           Type                              Rotary

 Compressor                Model                          QJ250KD24A

                           Capacitor                     AC 400V, 30



◦ Jabse Service Manual Search 2024 ◦ Jabse PravopisonTap.bg ◦ Other service manual resources online : FixyaeServiceinfo