Service Manuals, User Guides, Schematic Diagrams or docs for : HP Publikacje HP-Catalog-1948

<< Back | Home

Most service manuals and schematics are PDF files, so You will need Adobre Acrobat Reader to view : Acrobat Download Some of the files are DjVu format. Readers and resources available here : DjVu Resources
For the compressed files, most common are zip and rar. Please, extract files with Your favorite compression software ( WinZip, WinRAR ... ) before viewing. If a document has multiple parts, You should download all, before extracting.
Good luck. Repair on Your own risk. Make sure You know what You are doing.




Image preview - the first page of the document
HP-Catalog-1948


>> Download HP-Catalog-1948 documenatation <<

Text preview - extract from the document
                      HP Archive


This vintage Hewlett Packard document was preserved and distributed by
                         www. hparchive.com
                      Please visit us on the web !




                    On-line curartor: Glenn Robb
   AUDIO OSCILLATORS
        AUDIO SIGNAL
         GENERATORS
        VACUUM TUBE
          VOLTMETERS
UHF SIGNAL GENERATORS
FREQUENCY STANDARDS
        SQUARE WAVE
         GENERATORS
     WAVE ANALYZERS
DISTORTION ANALYZERS
          AMPLIFIERS
        ATTENUATORS
          ELECTRONIC
   FREQUENCY METERS
       FM BROADCAST
           MONITORS
          REGULATED
     POWER SUPPLIES
         ELECTRON IC
       TACHOMETERS



 CATALOG
   19-A



                         laboratory instruments
                          F O R      S P E E D        A   N   D     A C C U R A C Y



                        HEWLETT-PACKARD COMPANY
                        395   PAGE   MILL   R O A D   PALO        ALTO, C A L I F O R N I A
INDEX

A complete, easy-to-use index of all -hp- in-
struments will be found inside this cover flap.
This quick-reference index lists -hp- instru-
ments by function and model number, and
gives brief data on frequency range and other
characteristics.



CATALOG                              19-A

HEWLETT- PACKARD COMPANY
395 PAGE MILL ROAD*PALO ALT0, CALIFORNIA
                                                   FREQUENCY                               CHARACTERISTICS                      PAGES


                                10                                                           Binding Post                      33
       HARDWARE-':
                                                                           Flexible coupler, ceramic insulated; permits mis-
                                14                                                  alignment of 1/32" and/or 5'               33

                                100A        100 kc, 10 kc, 1 kc, 100 cps     Accuracy 3 cps per mc per degree Centigrade       30-3 1
  LOWFREQUENCY
     STANDARDS
                        :       100B        100 kc, 10 kc, 1 kc, 100 cps       Temperature controlled; accuracy 0.001 %        30-3 1

                                                                             Controlled by 100A or 100B. Multipliers also
FREQUENCY DIVIDER               110                100 to 10 cps
                                                                                         available up to 1 mc                  30-31

                                200A             35 to 35,000 cps             Output 1 watt into 500 ohms; 1 % distortion      4-5-6-7
                                                                                      ..
                                                                                       .            .          "---
                                200B             20 to 20,000 cps             Output 1 watt into 500 ohms; 1   distortion      4-5-6-7
                                                                                                                 ---                     .

                                200C            20 to 200,000 CS
                                                               P            Output 10 volts into 1,000 ohms; 1% distortion     4-5-6-7
                            .                         _I                          ,                 -----
                                        j        7 to 70,000cps             Output 10 volts into 1,000 ohms;     distortion    4-5-6-7
RESISTANCE-TUNED
     OSCILLATORS
                                                                           Frequency setting closer than 1%; output 10 volts
                                2001              6 to 6,000 cps
                                                                                   into 1,000 ohms; 1 % distortion             4-5-6-7
                    ,

                                                                              Output 3 watts at 1 % and 1 watt at
                                201B             20 to 20,000 cps
                                                                                      distortion into 600 ohms                 8-9

                                                                              For low frequency studies. Output 10 volts
                                                  '/a to 1,000 cps
                                                                                    into 1,000 ohms; 1 YO distortion           10-1 1

                                                 2 to 70,000 cps            Output 10 volts into 1,000 ohms;     distortion    4-5-6-7
                                                                           Output 5 watts, 1 % distortion into impedances of
                                                 20 to 24000 cps           50, 200, 600, 5,000 ohms. Output VTVM and 110
                                                                                       db attenuator, 1 db steps
                                                                                                                               12-13

                                205AG            20 to 20,000 cps
                                                                           Some as 205A, plus separate VTVM for complete
                                                                                        gain measurements                      12-13
    AUDIO SIGNAL                                                                            --------
     GENERATORS                                                            Output 5 watts, 3% distortion into 50, 200, 500,
                                205AH               1 to 100 kc            5,000 ohm impedances. Output VTVM and 110 db
                                                                                         attenuator, 1 db steps                12-13
                                                                           Output +15 dbm with less than 0.1% distortion
                                206A             20 to 20,000 cps          into 50, 150, 600 ohm impedances. Output VTVM
                                                                                 and 11 1 db attenuator in 0.1 db steps        14-15

                                                                           Output 50 volts peak to peak; 1,000 ohm internal
    SQUARE WAVE                 210A             20 to 10,000 cps
                                                                               impedance; 70 db attenuator 5 db steps          10-1 1
      GENERATOR

                                                                           Variable selectivity; measurement range 1 mv to
  WAVE ANALYZER                 300A             30 to 16,000 cps
                                                                                        500 volts; 5% accuracy                 24-25
                                                                                                                                     CAOLS


                                                                             Measures total distortion as low as 0.1%. 70 db
                                             400 cps and      kc
                                                                                  attenuator, 1 db steps for comparison             20-2 1
                  %           -   -   -                                    I_-_.---

                             320B          50, 100, 400 cps and
                                                                                                Same as 320A                        20-21
                                              1 5 and 7.5 kc
                                               ,
                                  -       30,50,100,400,1,000
                                                           cps;             Measures total distortion os low as 0.1%. Input
     DISTORTION
     ANALYZERS
                             325B          5 , 7.5, 10 and 15 kc       ,
                                                                              amplifier and complete VTVM each usable               22-23
                                                                                               separately

                                                frequency 20 to               Similar to 325B but measures at any frequency
                             330B               20,000 cps                               and includes AM detector                   22-23
                                                                            Similar to 3 0 1 no AM detector. Meter has VU
                                                                                        31,
                                            Any frequency 20 to
                             330C               20,000 cps
                                                                              characteristics to meet FCC requirements for
                                                                                             FM broadcasting
                                                                                                                                    22-23
  F BROADCAST
   M                                                                         FCC approved. Monitors carrier frequency and
      MONITOR
                             335B              88 to 108 mc                    modulation. High fidelity output for aural
                                                                       ,                      monitoring
                                                                                                                               ~




                                                                               110 db, 1 db steps; 5 watts, 500 ohm level.
                                               Max 100 kc                        Bridged T type. Accuracy 1 db in 50 db
                                                                                                at 100 kc
                                                                                                                                    32-33
   ATTENUATORS

                                               Max 100 kc                             Same as 350B but 600 ohm level                32-33
                                                                                 .                     .

                                                                            Nine ranges 0.03 to 300 volts full scale. Accuracy
                                              10 cps t 1 mc
                                                      o                     *3% to 100 kc, f5% to 1 mc. Average reading.            26-27
                                                                                          Calibrated in rms.

                                                                            AC: six ranges 1 to 300 volts. DC: seven ranges
   VACUUM TUBE                              20 cps to 700 mc                    1 to 1,000 volts. Resistance: seven ranges          28-29
     VOLTMETERS                                                                          0.2 ohm to 500 megohms
                                                                   .
           AND
    ACCESSORIES              455A                                           Connects probe of 410A across 50 ohm transmis-
                                                                                       sion line. Type N fittings                   40

                                                                            Connects probe of 410A to open end of 50 ohm
                             458A              to 1,000 mc
                                                                                   transmission line. Type N fittings               40

                                                                            40 db and 20 db stabilized gain. Input imped-
                                                                                         shunted by approximately 15 uuf.
                                                                                                                                    34-35

     ELECTRONIC              500A
                                                                                                                                    36-37
FREQUENCY METER
                                             5 cps to 50 kc
                                                                   I        Ten ranges, * 2 %   accuracy. Input 0.5 to 200 volts




                             505A          300 to 3,000,000 rpm                         Ten ranges, *2%     accuracy                37
     ELECTRONIC
    TACHOMETER
                             505B            5 to 50,000 cps                     Same as 505A except calibrated in cps              37

                                                                            Calibrated output 0 1 microvolt to 0.1 volt. Internal
                                                                                               .
                             610A            500 to 1,350 mc
                                                                                   pulse modulation. Direct calibration             20-2 1

                                                                            Direct reading. Pulse modulation, CW and FM.
                                            1,800 4,000 mc
                                                to
                                                                                Calibrated output 01 microvolt to 0.2 volts
                                                                                                   .                                18-19
                      ....                                                      --
                                                                            Direct reading. Six bonds. Output 3 volts to 600
                                             10 cps to 10 mc                     ohm load. VTVM and output attenuator               16-1 7

                                                                            Any dc voltage 180 to 360 for 0 to 75 ma load;
  POWERSUPPLY                710A                                             approximately 1 % regulation. Also 6.3 volts,         34-35
                                                                                              5 amps ac.
                                                                   -
SPEED AND ACCURACY ARE INTEGRAL PARTS OF EVERY - h p - INSTRUMENT




testing are made possible by the use of -hp- instruments. Although each is tai-
lored for very specific jobs, -hp- laboratory instruments have certain outstanding
"family" characteristics. No zero setting, little or no adjustment during opera-
tion, virtual independence of line and tube characteristics, full protection against
overloads, simple, accurate calibration, and streamlined circuits for clean and
trouble-free performance are qualities you will find throughout the -hp- line.


-hp- instruments are essential and versatile tools in the fields of television, fre-
quency modulation, radar, industrial heating, communications, carrier current,
equipment manufacture, experimental work, broadcasting, industrial testing.
Here is a partial list of the measurements that can be made with standard -hp-
instruments : distortion, frequency, gain, voltage, network response, harmonic
analysis, amplifier frequency response. They are also useful to establish standard
frequencies, establish standard ratios by attenuation, and provide voltage for
bridge measurements. Let -hp- instruments, products of sound engineering
and precision manufacture, solve your testing and measuring problems.
ENGINEERING TIME                                   IS AN         EXPENSIVE                    COMMODITY...


Probably in no other field is proper instrumentation so          be exercised, not only in making the measurements them-
vitally important as in electronics. Lacking the proper in-      selves, but in interpreting the results.
struments, it is not only difficult to design equipment cor-        Engineering time is a very expensive commodity. To em-
rectly in the first place, but often impossibleto tell whether   ploy it most efficiently, too much thought cannot be given to
it is behaving Properly when completed.                          the selection of the proper tools. -hp- instruments are designed
                                                                 with convenience second only to accuracy in their require-
To describe fully the performance of one of the simplest elec-   ments. By minimizing the time needed for routine measure-
tronic devices-a single-stage amplifier-requires the meas-       ments, and by guaranteeing the accuracy of the results, -hp-
urement of operating voltages and currents, gain, frequency      instruments render an outstanding service toward the ad-
response, overload points, harmonic distortion, and noise        vancement of the science of electronics. O n the following
level. In more complex apparatus the list would be greatly       pages you will find complete descriptions of a great many
expanded. Many of these measurements must be made in             -hp- instruments. Please feel free to write us for any assist-
high-impedance circuits where great care and judgment must       ance or further information which you may require.


                                                                                                                               3
       MODEL 200

                  AUDIO OSCILLATOR




                                                         RESISTANCE-TUNED PRINCIPLE

                                                     HERE   is a sound research story behind this revolution-
                                                      ary -hp- Resistance-tuned Audio Oscillator. Although
    ADVANTAGES:
                                                      audio-frequency oscillators have always been standard
       No zero setting. Great stability       equipment throughout the communications and electronics
       Constant output                        fields, there were many "bugs" in types commonly available.
       Wide frequency range                   These disadvantages included low stability, especially in the
       Logarithmic scale                      lower frequency ranges; need for constant resetting to insure
       Low distortion. Light weight
                                              accuracy; low portability, because of the essential weight and
                                              bulk of the instrument. So -hp- engineers set out to design
                                              and perfect an audio-frequency oscillator which would com-
    USE THEM FOR:
                                              bine the high stability and very wide range of the coil-
       Amplifier testing                      condenser type with the flexibility of operation of the beat
       Broadcast transmitter audio response   frequency type. The result is the basically new Resistance-
       Source of voltage for bridge           tuned Audio-frequency Oscillator, based on a new funda-
         measurements                         mental circuit and resulting in new speed and accuracy for
       Modulating signal generators           electronic tests and measurements.
       Supersonic voltage source                 The fundamental resistance-tuned circuit of -hp- Audio
       Driving mechanical systems             Oscillators is shown above. The resonant frequency of this
       Synchronizing pulse generators         network is inversely proportional to the product of resistance
       Loud speaker resonance tests           and capacity. Thus the change in resonant frequency of this
                                              circuit is three times as great as that of the coil and condenser
                                              circuit. A ten to one frequency change is easily possible with
                                              the resistance-tuned circuit.

4
   The resistance-capacity (frequency determining) network              -hp- Resistance-tuned Audio Oscillators provide an excel-
is operated in conjunction with a stabilized amplifier. Positive     lent source of voltage for accurate bridge measurements. The
feedback is applied to this amplifier through the resistance-        output is sufficient to drive signal generators and other equip-
tuned network, resulting in a very high effective Q for the          ment requiring considerable power. Certain models are also
circuit. See figure 1 . Negative feedback is also used, and          adapted to work in the supersonic range:
operates in conjunction with a non-linear resistor to limit             The usefulness of these oscillators is greatly increased be-
amplitude and decrease distortion. It also helps in providing        cause they are small and light in weight; thus easy to carry
a constant and extremely stable output over the entire range.        around. In short, the speed and accuracy of -hp- Resistance-
See figure 2 .                                                       tuned Audio Oscillators make them ideal for an almost end-
                                                                     less number of exacting jobs.
                    NO ZERO SETTING

   The excellent physical layout of -hp- Audio Oscillators has                             SPECIFICATIONS
much to do with their satisfactory performance. Thermal drift
is kept at a minimum by proper placement of components, and             Six standard models are available. The Models 200A and
by means of low temperature coefficient elements in the resist-      200B have a transformer-coupled output amplifier which will
ance network. Furthermore, this thermal drift is not magni-          deliver 1 watt into a matched load and are principally de-
                                                                     signed for use in audio testing. The Models 200C and 200D
fied, as is the case with the beat frequency type oscillator. Thus
calibration is accurate under all operating conditions, without      have a resistance-coupled output amplifier to provide uniform
                                                                     output voltage over their wide frequency range; they are prin-
the inconvenience of constant zero setting, even within the
                                                                     cipally useful when handling a wide range of frequencies,
first few minutes of operation. The constant output of these
oscillators makes it easy to check the frequency response of the     where a smaller amount of power is sufficient. Model 202D is
apparatus quickly, easily, accurately.                               a modification of Model 200D, with the frequency range ex-
                                                                     tended down to 2 cycles per second. It is particularly useful
                                                                     where it is necessary to generate an extremely wide range and
                                                                     where low frequencies are involved, as in mechanical vibra-
                                                                     tion problems. The Model 2001 is an oscillator of the band
                                                                     spread type. It is intended for interpolation work and for
                                                                     applications where it is necessary that the frequency of oscilla-
                                                                     tion be known very accurately. These oscillators are supplied
                                                                     in a relay rack mounting, as the 200AR, 200BR, 200CR,
                                                                     200DR, 202DR, and 200IR.
         Figure 1
                    FREQUENCY
                                                             I
                    ONLY THREE DIALS
  There are only three controls on the panel. They are the                                 DISTORTION AND AMPLITUDE CHARACTERISTICS       I
main frequency dial which covers a frequency range of 10 to
1; a range switch which selects the desired frequency band,
and an amplitude control to vary the output signal level.

                              USES
   The primary function of an audio-frequency oscillator is
to generate an accurately controlled signal of known fre-
quency. This signal may be used to check the performance of
audio amplifiers, broadcast transmitters, and similar equip-
ment. Although applications in the related fields of electronics
are of first importance, the usefulness of the -hp- Resistance-
tuned Audio Oscillator is by no means limited to the electrical
engineering fields. They may be used, for example, to drive
mechanical systems, in order to measure resonance and sta-
bility. Other measurements of mechanical equipment include
measurements of the output frequency of rotating equipment,
such as generators and dynamotors.


                                                                                                                                      5
                                                                            Output: The Models 200A and 200B will supply one watt
                                                                         or 22.5 volts output into a matched resistance load of 500
                                                                         ohms, and 25 volts on open circuit. Models 200C, 200D,
                                                                         202D, and 200I will deliver 100 milliwatts or 10 volts into
                                                                         a 1000 ohm load. The internal impedance of the output am-
                                                                         plifier is in the order of 50 ohms at 1000 cps.

                                                                            Frequency Response: The output voltages of Models
                                                                         200A and 200B are constant within plus or minus one decibel
                                                                         from 20 cps to 15 kc. The output voltage of the Model 200C
                                                                                                                                             t
                                                                         is constant within plus or minus one decibel from 20 cps to
                                                                         150 kc. The output voltages of the Models 200D and 202D
                                                                                                                                             i
                                                                         are constant within plus or minus one decibel from 7 cps to
                                                                         70 kc. The Model 202D will be within plus or minus 2 deci-
                     FREQUENCY RANGE
                                                                         bels from 2 cps to 7 cps. The frequency response of the 200I
Model   200A        . . . . . . . .                   35 cps to 35 kc
                                                                         is plus or minus one decibel from 6 cps to 6,000 cps.
Model   200B        . . . . . .   .           .       20cps to 20 kc
Model
Model
        200C
        200D
                    . . . . . .
                    . , , , . .
                                . .
                                . .
                                                      20 cps to 200 kc
                                                       7 cps to 70 kc      Distortion: The total rms distortion contained in the             iI
Model   202D        . . . . . . . .                    2 cps to 70 kc    waveform of the various models is within the following
Model   200I        . . . . . . . .                    6 cpstp 6 k c     limits: Models 200A and 200B, less than 1 % distortion from
    Calibration: The dial is calibrated directly in cycles for
                                                                         35 cps to 15 kc. Model 200C, less than 1 % distortion from 20
                                                                         cps to 100 kc. Model 200D, less than 1% distortion from 10
                                                                                                                                             I
the lowest range. A switch selects the range and indicates the
                                                                         cps to 70 kc. Model 202D, less than 2 % at rated output volt-       I
proper multiplying factor. The dial calibration of Models
                                                                         age from 10 cps to 70 kc. Model 200I, distortion less than 1 %
200A, 200B, and 200C covers approximately 180 degrees,
                                                                         above 10 cps, and only slightly more than this at lower fre-
with an equivalent scale length of 20 to 30 inches. Models
                                                                         quencies.
200D and 202D have dial calibrations covering approxi-
mately 300 degrees with a scale length of about 60 inches.                 Hum Voltage: On all models, the hum voltage is less
Model 200I is calibrated over approximately 300 degrees,                 than 0.1 % of maximum output voltages.
and has a scale length of approximately 90 inches.
                                                                           Power Supply: 115 volts, 50/60 cycles, 60 watts.
                          200A                            200B
Range 1     ,   ,    35-350 cps      . . . . .           20-200 cps         Mounting: The cabinet models are mounted in an at-
Range 2     . .      350-3500cps       . . . .         200-2000 cps      tractive steel cabinet finished in wrinkle gray.
Range 3     ,   ,    3500cps-35kc      , . .          2000cps-20kc          The relay rack mounting fits the standard 19" relay rack
                          200C                             200D          with Y4'' spacing. The dust cover mounts on the chassis and
Range   1   . , 20-200cps . . . . . 7-70cps                              is removable from the rear.
Range   2   . . 200-2000cps . . . . 70-700 cps
Range   3   , . 2000cps-20kc . . . . 700-7000cps                         Model       Mounting     Length    Height   Depth         Weight
Range   4   . . 20-200 kc . . . . 7000cps- 70 kc                         200A        Cabinet       16"        7"        9"         32 Ibs.
Model 202D is similar to Model 200D, with the addition of a              200B        Cabinet       16"        7"        9"         32 Ibs.
2-50 cps band covering approximately 200 degrees on the main             200C        Cabinet       16"        7"        9"     7   30Ibs.
tuning dial.
                                   2001                                  200D        Cabinet       17"        8Y4"     11"         32 Ibs.
Ax1     . . .         6 - 20 cps          Bx10    . . 200- 600 cps       202D        Cabinet       17"        8Y4"     11"         32 Ibs.
Bx1     .   ,   .   2 0 - 60 cps          Ax100   . . 600-2000cps        2001        Cabinet       17"        8y*"     10%"        32 Ibs.
Ax10    . . .       60-200 cps            Bx100   . . 2000-6000 cps      200AR       Relay Rack    19"        7I'       9"         35 Ibs.
                                                                         200BR       Relay Rack    19"        7`*       9"         35 Ibs.
   Stability: Under normal conditions the frequency drift is
                                                                         200CR       Relay Rack    19"        7"        9"         35 Ibs.
less than & 2 % or 0.2 cps (whichever is greater) including
                                                                         200DR       Relay Rack    19"        8Y4"     11"         37 Ibs.
initial warm-ups. Plus or minus 10 volt line voltage variations
                                                                         202DR       Relay Rack    19"        8Y4"     11"         37 Ibs.
change the frequency less than 2 0 . 2 % at 1 kc. No zero set-
                                                                         200IR       Relay Rack    19"        8%"      11"         37 Ibs.
ting is necessary on these oscillators. On Model 200I, if the
                                                                            Average shipping weight 42 Ibs.
ranges are standardized against a suitable frequency standard
from time to time, accuracy better than 1 % can be maintained.                      Data subject to change without notice.


6
                   200B AND 200C                                                            2008)
Here is the main tuning dial of -hp- Models 200B and 200C        Main tuning dial of -hp- Model 200D is calibrated over ap-
Audio Oscillators. Range is 20 cps to 20 kc on 200B, with        proximately 300' and has an effective scale length of about
dial calibrated over approximately 180' and effective scale      60". This wide range instrument (from 7 cps to 70 kc) owes
length of about 20"; 200C has range of 2 0 cps to 200 kc and     much of its speed and accuracy of operation to the precisely
effective scale length of about 26".                             calibrated and easily controlled tuning dial pictured above.




                      202D                                                                   200I
The -hp- Model 202D is a modification of the 200D, which         Main tuning dial of the 200I, which is an oscillator of the
extends the range down to 2 cps. The tuning dial is calibrated   band-spread type, intended for comparison work. The dial is
over approximately 300' ; the effective scale length is about    calibrated over approximately 300' with effective scale length
75". Before calibration, all -hp- Audio Oscillators are oper-    about 90" and range of 6 cps to 6 kc. Each Model 200I is
ated for a long period so as to be completely stabilized.        carefully hand calibrated to insure maximum accuracy.

                                                                                                                             7
       MODEL 201B

                  AUDIO OSCILLATOR
                               STABILIZED                 POWER
                               AMPLIFIER                 AMPLIFIER




                                                        CHECK THE ADVANTAGES OF
                                                        THIS FINE, NEW OSCILLATOR
    ADVANTAGES:
        3 watts output                           N FM and other fields where high fidelity is important,
        Distortion less than    '/2%            this new -hp- Model 201B Audio Frequency Oscillator
        Low hum level                           will meet every requirement for speed, ease of operation,
        New dial with ball-bearing drive     accuracy and purity of wave form. The product of 6 years of
        Accurate expanded frequency
                                            -hp- oscillator development, this new oscillator has many
          calibration                       brand new features, in addition to the revolutionary resistance-
        Improved control of output level    tuned circuit which has made -hp- a by-word in engineering
                                            circles.
    USE IT FOR:                                The 201B has an accurate, convenient method of frequency
                                            control. The 6" dial, with smooth ball-bearing action, may be
        High fidelity amplifier testing
                                            tuned by a directly controlled knob, or for still greater accu-
       Transmission line measurement
                                            racy, may be set by the vernier which has a ratio of 6 to 1 to
        Loud speaker testing
                                            the main dial. The illuminated main dial is designed so that
        Frequency comparison
                                            parallax is eliminated. It is calibrated over 300 degrees with
                                            approximately 95 calibration points and has an effective scale
                                            length of about 47 inches. Frequency range is 20 cps to 20 kc.


8
              INCREASED POWER OUTPUT                                  Frequency Calibration: The calibration is direct in
                                                                   cycles per second for the lowest band. Approximately 95
   The amplifier delivers up to 3 watts of power into a 600
                                                                   calibration points are provided over a 300-degree arc. The
ohm resistance load, with distortion held to 1 76. Thus there is
                                                                   dial is 6 inches in diameter, illuminated and driven by a
sufficient power available for driving almost any kind of lab-
                                                                   vernier knob having 6 : 1 ratio. The effective scale length for
oratory or production equipment. Harmonic distortion may
                                                                   the three bands is 47 inches.
be kept to less than y2of 1 %, if the output of the amplifier is
limited to 1 watt.                                                    Stability: Under normal temperature conditions the fre-
   Another important feature of this oscillator is the provision   quency stability is better than -+2%, including the initial
which is made for standardizing each frequency range against       warm-up drift. Plus or minus 10 volt line voltage variations
a reliable standard, such as -hp-'sModel 100B Secondary Fre-       will result in no change in the output frequency. Adjustments
quency Standard. By standardizing the instrument regularly,        are provided on each band to standardize the calibration
frequencies can be depended upon to be better than 1 %             against an accurately known frequency. With standardization
accurate.                                                          the accuracy may be maintained better than & 1 %.
        DUAL CONTROL FOR OUTPUT LEVEL                                 Output: The instrument is rated at a maximum of 3 watts
   A new departure in oscillator design is the dual method         or 42.5 volts into a 600 ohm resistive load. Maximum no load
for controlling output level. A volume control which is ahead      voltage is at least 50 volts. The impedance looking back into
of the amplifier controls the voltage at which the amplifier       the output circuit (zero attenuator setting) is in the order of
operates. An output attenuator is provided to attenuate the        75 ohms. With attenuator set at a value of 10 db or more the
signal delivered by the amplifier. Attenuation is approxi-         impedance looking back into the output is 600 ohms.
mately linear from zero to 40 db. Both hum level and output
                                                                     Frequency Response: The output voltage is constant
voltage are thus attenuated together. As a result, hum level       within & 1 db over the frequency range of 20 cps to 20,000
may be kept 60 db or more below the signal level, a special
                                                                   cps.
advantage in cases where small test signals are used.
   The impedance looking back into the output circuit is about       Distortion: The total rms distortion of the output wave
50 ohms ; thus the voltage regulation for varying loads is ex-     over the range of 20 cps to 20,000 cps is less than the follow-
tremely good. For measurements where it is desirable to have       ing limits :
impedance looking back into the instrument of 600 ohms, as               3 watts output                  1% distortion
in transmission measurements, the attenuator may be used to              1 watt output                  .5% distortion*

give about 10 db or more of attenuation, making the reflected                *Down to 50 cps, at 20 cps 1% distortion.
impedance of the instrument about 600 ohms.                          Volume Control: Two controls are provided for varying
                                                                   the output of the instrument:
                  IMPORTANT DETAILS                                    1. An "Amplitude Control" adjusts the amount of oscil-
   Care has been taken to perfect every detail of this new         lator voltage fed to the output amplifier.
oscillator. Improved chassis layout and placement of com-             2. An "Attenuator" attenuates the output of the amplifier.
ponent parts minimizes thermal drift. The voltage on the           It is a variable T Pad having an attenuation range of 0 to in-
oscillator is maintained constant with an electronic voltage       finity. Approximately linear in region 0 to 40 db.
regulator. The entire instrument is characterized by greater
mechanical rigidity; the tuning assembly is mounted on a              Hum Voltage: The hum voltage is less 0.03% of maxi-
sturdy cast aluminum frame. The chassis itself is made of          mum output voltage. If the output attenuator is used to con-
aluminum; the oscillator is light in weight and easy to handle.    trol the output (with Amplitude control set for maximum
                                                                   rated power output) the hum level will be less than -1%
                                                                   below any signal level.
       SPECIFICATIONS, MODEL 201 B                                    Power Supply: 115 volts i 10 volts, 50/60 cycles.
              A F OSCILLATOR                                       Power consumption: 75 watts. Plate supply voltage to oscil-
                                                                   lator section is electronically regulated.
   Frequency Range: The frequency range is from 20 cps
to 20,000 cps covered in three bands.                                Mounting: Cabinet Models are mounted in an aluminum
                                                                   cabinet finished in wrinkle gray. Size: 17 in. long x 81/2 in.
     Band                             Frequency Coverage
                                                                   high x 11 in. deep. Weight: 32 pounds. Shipping Weight:
      xl                                 20 - 200 cps
      x10                               200 - 2,000 cps
                                                                   46 pounds.
      XlOO                            2,000 - 20,000 cps                      Data subject t o change without notice.

                                                                                                                                9
     LOW FREQUENCY OSCILLATOR




      MODEL 210A

     S Q UA R E WAVE GENERATOR




10
   HIGH ACCURACY FOR LOW FREQUENCY                                     Frequency Dial: 6" diameter. Reads directly in cps for
      MEASUREMENTS    TO 1000 CPS                                    two lower ranges. Dial is back of panel, illuminated, and is
                                                                     controlled by direct drive as well as a 6 to 1 vernier.
Now you can make low frequency measurements with all the
precision and stability associated with audio frequency work.          Accuracy of Calibrations: + 2 % .
This -hp- 202B oscillator blankets the low-frequency spec-             Frequency Stability: f 5 % under normal temperature
trum from `/2 to 1000 cps. Throughout this range it provides         conditions (including warm-up drift) . Less than t1% for
better wave form, higher stability and greater measuring ac-         power voltage changes of + l o % .
curacy than any instrument ever manufactured for industrial,
field or laboratory use.                                               Output: 10 volts into a 1000 ohm resistive load over the
                                                                     entire frequency range. Internal impedance approximately 25
                             USES                                    ohms at 10 cps.
The -hp- 202B gives maximum measuring speed and accuracy               Frequency Response: t l db 10 to 1000 cps.
for these important tests : Vibration or stability characteristics                         t 2 db 1 to 1000 cps.
of mechanical systems, electrical simulation of mechanical
phenomena, electro-cardiograph and electro-encephalograph              Distortion: Less than 1% total distortion, 1 to 1000 cps.
performance, seismograph response, vibration checks of struc-          Hum Voltage: Less than 0.1% of rated output voltage.
tural components, performance of geophysical prospecting
equipment,                                                             Recovery Time: 30 to 60 seconds on lowest frequencies.
               SPECIFICATIONS                                          Power: 115 volts t10 volts, 50/60 cps.
  Frequency Range: y2cps to 1000 cps in 4 ranges                       Size: 17" long, 123/4r' deep,           high.
    Range                                      Frequency               Mounting: Wrinkle gray panel, oak cabinet.
      A     . . . . . . . . . . . .            `/~-IcPs
       xl   . . . . . . . . . . . .              1--1ocps              Net Weight: 50 pounds. Shipping Weight: 92 pounds.
     x10    . . . . . . . . . . . .            10-100 cps
    XlOO    . . . . . . . . . . . .           100--1ooocps                         Data subject to change without notice.




     SQUARE W A V E S FOR R A P I D TESTING                            Output Attenuator: 70 db in 5 db steps.
            20 CPS TO 100 KC                                           Driving Voltage: 2 volts required. Input impedance 25,-
                                                                     000 ohms. May be internally driven with a-c power supply
The -hp- Model 210A Square Wave Generator provides an                voltage.
excellent source of square waves for production tests and ex-
                                                                       Mounting: Steel Cabinet: 15" long, 7jr high, 9" deep.
perimental purposes. The fundamental frequency range is 20
                                                                     Relay Rack: 19" long, 7" high, 8'' deep.
cps to 10,000 cps. A reasonably square wave may be obtained
at frequencies as high as 100 kc. The square wave frequency            Power Supply: Built-in. Operates from 115 volt 50/60
is synchronized from an external source of 2 or more volts.          cycle. Requires approximately 85 watts.
Output can be attenuated 70 db from a maximum voltage of               Net Weight: 30 pounds. Shipping Weight: 39 pounds.
50 volts, peak to peak. Output voltages balanced to ground.                      Data subject to change without notice.
                             USES
   The -hp- 210A is ideal for testing receivers, video ampli-
fiers, networks and transmitters ; to measure time constants or         I . Square wave distortion
provide a time base, check cathode ray sweep circuits, gen-             from poor high
                                                                        frequency response.
erate harmonics for frequency multiplication or control an
electronic switcher. It may also be used to indicate phase
                                                                        2. Square wave dirlor-
shift, frequency response, or transient effects.                        tion from poor response
                                                                        at both high and low
               SPEClFlCATlONS                                           frequencies.
  Frequency Range: 20 cps to 10,000 cps. Voltage rise
time: Approximately 1 microsecond to 90% of maximum,
Flat top of wave decays less than 1%,
                                                                        showing peak at 9 times
   Output Voltage: Approximately 50 volts, peak to peak,                square wave frequency.

open circuit. The output impedance is 1,000 ohms, balanced
to the ground.
                                                                                                                                11
            AUDIO SIGNAL GENERATOR
              RESISTANCE T U N E D
                 OSCILLATOR          WATT AMPLIFIER          VOLTMETER              1 DB STEPS




                                                                                                                      INPUT
                                                                                                   AMPLIFIER O NETWORK
                                                                                                              R
                                                                                                         UNDER TEST
                                                                                                                     OUTPUT




                                                                                S I X BASIC INSTRUMENTS COMBINED
         ADVANTAGES:                                                               TO SPEED G A I N MEASUREMENTS
             No auxiliary equipment needed                                   ALL THE   necessary instruments for accurate gain or fre-
             Range-20 to 20,000 cps                                             quency response measurements have been assembled
             5 watts output, less than 1 distortion                              by -hp- engineers in one compact unit. (See block dia-
             No zero setting                                             gram.) No auxiliary equipment is required.
             Supplies known voltage
                                                                            This Audio Signal Generator brings new speed and ease to
             Output meter calibrated in volts and decibels
             Standardized frequencies instantly available
                                                                         testing jobs. Any desired frequency within the range of 20
             Separate input meter for gain measurements                  to 20,000 cps is made available by the resistance-tuned audio
             Wide range of output impedances                             oscillator, These frequencies are developed at any desired
                                                                         voltage between 150 volts and 50 micro-volts.
                                                                            To make amplifier or network gain measurements with
         USE IT FOR:
                                                                         the -hp- Model 205 AG Audio Signal Generator, the operator
             Amplifier gain measurements                                 simply connects input and output leads to the binding posts.
             Network frequency response                                     Two vacuum tube voltmeters are provided, one to measure
             Source of voltage for distortion                            input and the second to measure output of the device under
               measurements
                                                                         test. The input meter has a range of minus 5 db to plus 49 db,
             Broadcast transmitter audio response
                                                                         with an input impedance of 5,000 ohms. The attenuator sets
             Loudspeaker response
                                                                         the output voltage, The output impedance can be instantly
,            General laboratory applications
                                                                         changed by means of a selector switch (line matching trans-
             Production testing
                                                                         former in the block diagram) to the commonly used imped-
                                                                         ances of 50, 200, 600, and 5,000 ohms, a convenience in

    12
matching various types of networks. The Model 205AG will             Output Meter: The output meter is calibrated directly in
supply 5 watts output with less than 1% distortion, and thus      volts at 600 ohms and in db above a 1 mw level (54.7 volts
is useful where sizeable amounts of power are required. Feed-     and plus 37 db full scale).
back is used for improved frequency response and lower               Input Meter:* The input meter has a range of minus 5 db
distortion.                                                       to plus 48 db based on a 1 mw level in 600 ohms. The meter
   The -hp- Model 205AG is well adapted to measuring fre-         scale is calibrated from minus 5 db to plus 8 db and a multi-
quency response and gain or loss of any network. The fre-         plier switch adds from zero to 40 db to the reading in 5 db
quency remains accurate, without the necessity of zero setting.   steps. The meter has an input impedance of 5,000 ohms.
-hp- Audio Signal Generators are built for heavy duty and           *Not included in Model 205A.
long, hard service.                                                  Input Meter Response: The frequency response of the
                                                                  input meter is within t 0 . 2 db over range from 20-20,OOO cps.
  AUDIO AND SUPERSONIC MODELS AVAILABLE
                                                                     Output Attenuator: The output attenuator provides 110
   There are three models of signal generators. The -hp-
                                                                  db in 1 db sieps. It consists of a 100 db attenuator with 10 db
Model 205AG provides all of the basic components to make
                                                                  steps and a 10 db attenuator with 1 db steps.
a complete gain measurement in one unit. The -hp- Model
                                                                     Power Supply: 115 volts -+lo volts, 50/60 cycles.
205A is similar to the 205AG except that the input vacuum
                                                                  Power consumption: 125 watts.
tube voltmeter is eliminated. For supersonic measurements
the -hp- Model 205 A H Signal Generator is available. This in-       Mounting: Available in either relay rack or cabinet mount-
strument is similar to the -hp- Model 205A but covers a fre-      ing. Panel size on either instrument, 19" x 1OY2", Cabinet
quency range of 1 kc to 100 kc.                                   models are mounted in oak cabinets. Panels are finished in
                                                                  wrinkle gray enamel with machine engraved designations.
     SPECIFICATIONS, MODELS 2 0 5 A G                                Net Weight: 73 pounds. Shipping Weight: 116 pounds.
                A N D 205A
  Frequency Range: The frequency coverage is 20 cps to               MODEL 205AH SUPERSONIC SIGNAL
20,000 cps, in three ranges.                                                   GENERATOR
   Calibration: The dial is calibrated directly in cycles for
                                                                     Frequency Range: 1 kc to 100 kc, in two ranges.
the lowest range, 20 cps to 200 cps. A switch selects the de-
                                                                     Power Output: 5 watts at 3 % distortion, 3 watts at 1 %
sired range and indicates the proper multiplying factor. Each
                                                                  distortion, 1 watt at Y2% distortion.
range covers approximately 270 degrees on the 61/2" main
dial. Range 1 covers 20 cps to 200 cps; Range 2 covers 200          Load Impedances: 50,200, 500 and 5,000 ohm resistive.
                                                                  The output circuit is balanced and center tapped and any
cps to 2,000 cps; and Range 3 covers 2,000 cps to 20,000 cps.
                                                                  terminal may be grounded. The internal impedance is ap-
   Stability: Under normal temperature conditions the fre-        proximately 1/7 of the load impedance with zero attenuator
quency will drift less than 2% over long periods of time. Each
                                                                  setting. The internal impedance approaches the load imped-
range is provided with an internal adjustment so that 1%          ance with attenuator settings of 20 db or more.
accuracy may be maintained if required.
                                                                     Frequency Response: -t- 1 db from 10 kc reference.
   Output: Five watts output will be delivered to a matched
                                                                     Hum level: The hum level is at least 65 db below output
resistance load.
                                                                  voltage or 65 db below 1 milliwatt into 500 ohms, whichever
   load Impedances: A switch selects transformer taps for         is greater.
use with loads of 50, 200, 600 and 5,000 ohm resistive loads.
                                                                     Output Attenuator: Range: 0 to 110 in 1 db steps.
The output circuit is balanced and center tapped and any
                                                                  Accuracy: $" db in first 80 db, 3 db in last 30 db.
terminal may be grounded. The internal impedance is ap-
proximately 1/6 of the load impedance with zero attenuator           Power Supply: 115 volts, 50-60 cycles, 125 watts.
setting. The internal impedance approaches the load imped-          Accuracy o Frequency: + 2 % .
                                                                                 f
ance with attenuator settings of 20 db or more.                     Stability of Frequency: f l / 2 % after 1/2 hour warm up.
   Frequency Response: The frequency response of the
                                                                  Line voltage changes of t10 volts have negligible effect on
system beyond output meter is down 2.0 db at 20 cps and 1 db      frequency as power supply to oscillator is regulated.
at 20,000 cps (at levels from +37 to -10 dbm) . Drop in              Output Meter: The output meter is calibrated directly in
response exceeds these limits at levels lower than -10 dbm.       volts at 500 ohms and in db above 1 milliwatt level (50 volts
   Distortion: The distortion is less than 1 % at rated output    and +37 db, full scale).
at all frequencies above 30 cps.                                     Mounting: Same as 205 AG.
  Hum Level: The hum level is 60 db below the output volt-           Net Weight: 63 pounds. Shipping Weight: 110 pounds.
age or 90 db below zero level, whichever is the larger.                       Data subject to change without notice.


                                                                                                                             13
     8 MODEL 2 0 6 A

      AUDIO SIGNAL GENERATOR




                                                  C O N T I N U O U S L Y VARIABLE A U D I O SIGNALS
                                                              LESS T H A N 0.1% DISTORTION
     ADVANTAGES:
                                                          HE newly-developed -hp- Model 206A Audio Signal
          Continuously variable a-f voltage
                                                         Generator provides a source of continuously variable
          Accuracy 0.2 db, any level
                                                         audio frequency voltage at a total distortion level of less
          High stability                          than 0.1%. This unique feature, coupled with simple,
          Harmonic distortion less than 0.1 Yo    straight-forward circuitry, rugged construction and typical
          1 1 1 db attenuator, 0.1 db steps       -hp- ease of operation, makes this new signal generator ideal
                                                  for use in the maintenance of FM broadcasting units and high
     USE IT FOR:                                  fidelity audio systems.
         A-f voltage source
                                                                    CIRCUIT DESCRIPTION
          Checking FM transmitter response and
            distortion                               The circuit arrangement of the Model 206A is shown in the
                                                  block diagram, Figure 1. The oscillator section is followed by
          Checking broadcast studio performance
                                                  a tuned amplifier, automatically tracked with the oscillator.
          High-quality amplifier testing
                                                  High selectivity of the amplifier reduces the harmonic volt-
         Transmission measurements                ages generated by the oscillator section. This serves to reduce
                                                  the percentage of harmonic distortion in the voltage reaching
                                                  the instrument's output terminals,


14
           The selective amplifier is followed by an output amplifier,                         SPECIFICATIONS
        a vacuum tube voltmeter, an attenuator and finally an output        Frequency Range: The frequency coverage is from 20
        matching transformer. An electronic voltage regulator sup-       cps to 20 kc in 3 ranges.
        plies plate voltage for the complete circuit.
                                                                            Calibration: The dial is calibrated directly in cycles for
                   FREQUENCY DETERMINING NETWORK                         the lowest range, from 20 to 200 cps. Each range covers ap-
                                                                         proximately 270 degrees of the 6" dial. The dial is located
          The frequency determining network in the instrument's          behind the panel and is illuminated. A six to one rim drive
       oscillator section is composed of low temperature coefficient     enables the equipment to be easily and quickly set to any de-
       elements, so that the instrument will have good stability over    sired frequency.
       long periods of time. The frequency calibration of the instru-
       ment is accurate within 1%. Frequencies from 20 cps to 20 kc         Stability: The frequency is calibrated to within better
       are continuously available. Three decade frequency ranges         than 1% when the instrument leaves the factory. The circuit
       provide an effective scale length of 47". Tuning dial is con-     elements in the frequency determining network have low
       trolled directly or with a 6 to 1 vernier micro drive for hair-   temperature coefficients and good stability so that excellent
       line adjustments. Dial is read through a no-parallax illu-        accuracy will be maintained over long periods of time.
       minated window.                                                     Output: The equipment will deliver an output level of
          The output of the amplifier is measured by a vacuum tube       + 15 dbm above 1 mw into impedance of 50, 150 and 600
       voltmeter. Indications can be read in either volts or dbm to      ohms. Approximately 10 volts are available into an open
       an accuracy of 0.2 dbm. Following the vacuum tube voltmeter       circuit.
       is a 11 1 db attenuator which allows the power output to be          Output Impedances: The generator has a matched in-
       varied in 0.1 db steps.                                           ternal impeda



◦ Jabse Service Manual Search 2024 ◦ Jabse PravopisonTap.bg ◦ Other service manual resources online : FixyaeServiceinfo