>> Download 200CD documenatation <<Text preview - extract from the document Calibration Record
Manufacturer Hewlett Packard
Model No. 200 CD
Contract No.
Serial No.
Test Conditions
Output connection: X Balanced Unbalanced
All measurements to Hewlett Packard Model 334A Distortion Analyzer
Load Resistance: 600 Ohms
Results
Test Relative
Frequency % Harmonic Output
(Hz) Distortion (dB #)
5 **
10 **
20
50
100
200
400
1,000
2,000
5,000
10 kHz
12.5 kHz
15 kHz
20 kHz
30 kHz
50 kHz
75 kHz
100 kHz
200 kHz
400 kHz
750 kHz * *
1 MHz * *
1.25 MHz * *
2 MHz * *
4 MHz * *
Notes: # Output flatness measured relative to 400 Hz. Zero 3.00 volts
* Denotes value beyond the range of the instrument under test.
** Denotes measurement limited by noise or capabilities of measuring instrument.
Maximum output level:
No load output voltage @ 400 Hz 20.00 volts
Loaded output 10.00 volts at 600 ohms
0.17 watts
Date: Remarks/Repairs: ** Meter damping was not sufficient
for accurate reading.