Text preview - extract from the document
                                                    HP 3000 Computer Systems




                                                              SERIES 37XE

                                                                    Installation Manual




                                 ~l)~:~K~~~
                       8010 Foothills Blvd., Roseville, Ca. 95678




Part No. 30457-90009                                                  Printed in U.S.A. 09/84
E0984
                           FEDERAL COMMUNICATION COMMISSION RADIO
                              FREQUENCY INTERFERENCE STATEMENT



The United States Federal Communications Commission (in Subpart J, of Part 15, Docket 20780)
has specified that the following notice be brought to the attention of the users of this product:

       "Warning: This equipment generates, uses, and can radiate radio frequency energy and
       if not installed and used in accordance with the instructions manual, may cause inter-
       ference to radio communications. It has been tested for compliance with the limits for
       Class A computing devices pursuant to Subpart J of Part 15 of FCC Rules, which are
       designed to provide reasonable protection against such interference. Operation of this
       equipment in'a residential area is likely to cause interference in which case the user at
       his own expense will be required to take whatever measures may be required to correct
       the interference."




       "This product has been tested and licensed by the Fernmeldetechnisches Zentralamt
       (FTZ) for use in West Germany. Included with the system is a registration postcard
       to be completed and mailed for all German installations."




                                             NOTICE


 The information contained in this document is subject to change without notice.

 HEWLETT-PACKARD MAKES NO WARRANTY OF ANY KIND WITH REGARD TO
 THIS MATERIAL, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES
 OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
 Hewlett-Packard shall not be liable for errors contained herein or for incidental or con-
 sequential damages in connection with the furnishing, performance or use of this material.

 Hewlett-Packard assumes no responsibility for the use or reliability of its software on
 equipment that is not furnished by Hewlett-Packard.

 This document contains proprietary information which is protected by copyright. All
 rights are reserved. No part of this document may be photocopied, reproduced or trans-
 lated to another language without the prior written consent of Hewlett-Packard Company.



                  Copyright (c) 1984 by HE\VLETT-PACKARD Company


                                               ii
                                                                      PRINTING HISTORY


New editions are complete revisions of the manual. Update packages, which are issued between editions,
contain additional and replacement pages to be merged into the manual by the customer. The dates on
the title page change only when a new edition or a new update is published. No information is
incorporated into a reprinting unless it appears as a prior update; the edition does not change when an
update is incorporated.

The sofiware code printed alongside the date indicates the version level of the software product at the
time the manual or update was issued. Many product updates and fixes do not require manual changes
and, conversely, manual corrections may be done without accompanying product changes. Therefore, do
not expect a one- to one correspondence between product updates and manual updates.



         First Edition .................................. Sept 1984




                                                                                                  0984
                                                                                                    iii
                                                                                  PREFACE

This manual describes the installation of an HP 3000 Series 37 Computer system. It is intended for use by
Hewlett-Packard Customer Engineers trained on the HP 3000 Series 37 computer systems.

Before the system can be installed, the site must be adequately prepared, as described in the HP 3000
Series 37 Site Planning and

Preparation Guide, part number   30457~90008.


The following information can be helpful in installing the system.

       HP-IB Diagnostic Manual Set                                                      PN 30070-60068

       CE Handbook                                                                      PN 30070-90010

       Diagnostic/Utility System Reference Manual                                       PN 30070-90043

       MPE System Utilities Reference Manual                                            PN 30000-90044

       System Operator and Resource Management Reference Manual                         PN 32033-90005

       Series 37 Installation Video Cassette                                                 PN 90304HZ

Service and Installation manuals for the peripheral devices installed with the system should be taken on
site if familiarity with the device is limited.

This manual is organized as follows:


Section I - Defines Hewlett-Packard and Customer responsibilities in receiving the system.

Section 2 - Describes the mechanical and electrical characteristics of the System Processor Unit (SPU) and
        the I/O Extender.

Section 3 - Provides general installation instructions for the system hardware.

Section 4 - Provides system and peripheral turn -on procedures.

Section 5 - Provides system configuration and verification information.

Section 6 - Lists the topics that should be covered when familiarizing the new system operator with the
        system.

Section 7 - Lists the steps in upgrading the Series 37 customer-installable system to the Series 37XE
        system.

Appendix A - Provides information for cabling terminals and modems to the Series 37XE system.




                                                                                                     0984
                                                                                                       v
                                                                                     CONTENTS


Section 1
RECEIVING THE SYSTEM



Section 2
SYSTENI GENERAL DESCRIPTION

Introduction........................................................................................... 2-1
SPU Physical Description........................................................................... 2-1
I/O Extender Physical Description............................................................... 2-1
System Cabinet Physical Description............................................................ 2-2
SPU Electrical Description......................................................................... 2 - 2
I/O Extender Electrical Specifications.......................................................... 2- 3
System Cabinet Electrical Specifications........................................................ 2- 3


Section 3
SYSTEM INSTALLATION

Introduction ........................................................................................... 3-1
Configurations........................................................................................ 3- 3
SPU Front Panel. ..................................................................................... 3-4
   Front Panel Key Switch......................................................................... 3-4
   Front Panel Status Indicators.................................................................. 3-4
   Front Panel LED................................................................................. 3-5
Installing the System Cabinet. .................................................................... 3-9
Connecting the SPU to the I/O Extender ....................................................... 3-9
Installing Devices in System Cabinet........................................................... 3-10
   Installing the HP 7945 Disc Drive.......................................................... 3-1 0
   Installing SPU and Extender in Cabinet................................................... 3-10
   Installing the HP 9144 Cartridge Tape Unit............................................. 3-11
   Installing Filler Panels......................................................................... 3-11
Configuring the SPU and the I/O Extender.................................................. 3-11
I/O Extender Service Note ....................................................................... 3-14
Installing the System Console.................................................................... 3-14
Installing Peripherals in System................................................................. 3-14
   Installing Disc Drives.......................................................................... 3 -16
   Installing Tape Drives.......................................................................... 3-17
   Installing System Printers..................................................................... 3-17
      Installing HP 2563/2565/2566 Printers.............................................. 3-18
      Installing HP 2680/HP 2688 Page Printers........................................... 3-18
   Installing Terminals............................................................................ 3-1 9
   Installing Plotters............................................................................... 3-19
System information Card.......................................................................... 3-19




                                                                                                               0984
                                                                                                                 vii
  CONTENTS (continued)


        Section 4
        TURNING ON THE NEW SYSTEM

        SPU/Peripheral Turn-on........................................................................... 4-1


        Section 5
        SYSTEM VERIFICATION

        Off-Line Verification ............................................................................... 5-1
        On - Line Verif ica tion. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. 5- 2


        Section 6
        TRAINING THE SYSTEM OPERATOR



        Section 7
        UPGRADE INSTALLATION

        System Upgrade...................................................................................... 7-1


        Appendix A
        CABLING INFORMATION




 0984
viii
                                                       FIGURES AND TABLES



LIST OF FIGURES

Figure   3-1.     Typical System Configuration.................................................... 3-2
Figure   3- 2.    System Cabinet Rail Locations and Device Positions ........................ 3-4
Figure   3-3.     SPU Front PaneL ................................................................... 3-5
Figure   3-4.     SPU/Extender Slot and Channel Assignments.............................. 3-13
Figure   A-I.     Cabling Diagram.............................. , ..................................... A-I


LIST OF TABLES

Table    3-1.    Allowable System Cabinet Configurations...................................... 3-3
Table    3-2.    Key Switch Definitions............................................................. 3-6
Ta ble   3- 3.   Front Panel LED Codes and Descriptions............... , ....................... 3-7
Table    3-4.    MPE Status Codes.................................................................... 3-8
Table    3-5.    Supported HP-IB Devices......................................................... 3-16
Table    3-6.    Maximum Number of Discs per Type on System............................ 3-16




                                                                                                              0984
                                                                                                                lX
   RECEIVING THE SYSTEM
~____________~IOO
                                                                                              1-
The Hewlett-Packard Customer Engineer (CE) is responsible for installing the HP 3000 Series 37XE
computer system in accordance with the information in this manual. This includes installation and
verification of the HP 3000 Series 37 SPU, I/O Extender, and any peripherals that are part of the system
order. Hewlett-Packard data terminals should be installed when appropriate. Refer to the policy on
installing HP Data Terminals, as described by the Computer Support Division.

The customer should immediately report any flaws to the HP Customer Engineer and to the carrier or to
the carrier's agent. Be sure to save all crates, cartons, boxes, and packing material for inspection. Do not
make any verbal reports of damage or missing items without making a written report. The Customer
Engineer should report problems that are HP's responsibility to the Support Engineer at the appropriate
HP division.

Missing or damaged items will be replaced without waiting for the settlement of claims. Items shipped to
replace damaged parts will be billed to the customer until the damaged parts are returned to
Hewlett-Packard. The customer should not release the carrier until the shipment is verified to be in good
working order.

The customer is responsible for initially unpacking, inspecting, and locating the system. Disposal of
packing material is also the responsibility of the customer.

Each Hewlett-Packard shipment has a packing list attached to one of the cartons, specifying the materials
shipped. In addition, unpacking instructions are provided as required.




                                                                                                      0984
                                                                                                       1-1
~_S_'t_I_S_"'_I_E_M G_E_N_E_R_A_L_D_E_S_C_R_IP_T_IO_N_1____ r:I.I',
                 __                                                                     ----'1
                                                                                                 l


INTRODUCTION

The HP 3000 Series 37XE system, product number 324S0A, is made up of the HP 3000 Series 37 System
Processing Unit (SPU), the I/O Extender, and the system cabinet. Each of the components is described
below.


SPU PHYSICAL DESCRIPTION

The Series 37 SPU consists of a five-slot card cage, a power supply, and battery backup circuitry. The
boards that make up the SPU are installed in the following slots:

       Slot 5 Central Processing Unit (CPU)    *
       Slot 4 Peripheral Interface Processor (PIC) or
              Advanced Terminal Processor (ATP37)       **
       Slot 3 5 12k byte Memory, ATP 37, PIC, or empty       ***
       Slot 2 5 12k byte or 2048k byte Memory      *
       Slot 1 ATP37     *
       *     Must be installed in this'slot.

       **     Do not move the PIC PCA unless four ATP37 PCAs and
             two Memory PC As are installed in the system.

       ***    This slot can be empty if one 2048k byte Memory PCA is installed.

When running some of the diagnostic programs, you may see messages that refer to the TIC. The acronym
refers to the Terminal Interface Controller. The TIC PCA is synonymous with the ATP 37 PCA.


1/0 EXTENDER PHYSICAL DESCRIPTION

The I/O Extender provides five additional slots for ATP37, PIC, INP, or other interface PCAs. The
backplanes, power supplies, battery packs, and rear panels of the SPU and I/O Extender are identical.

The differences between the SPU and the I/O Extender are:


       