Service Manuals, User Guides, Schematic Diagrams or docs for : IBM share SHARE_61_Proceedings_Volume_1_Summer_1983 B233 MVS For Small Systems Users; Lauzon

<< Back | Home

Most service manuals and schematics are PDF files, so You will need Adobre Acrobat Reader to view : Acrobat Download Some of the files are DjVu format. Readers and resources available here : DjVu Resources
For the compressed files, most common are zip and rar. Please, extract files with Your favorite compression software ( WinZip, WinRAR ... ) before viewing. If a document has multiple parts, You should download all, before extracting.
Good luck. Repair on Your own risk. Make sure You know what You are doing.




Image preview - the first page of the document
B233 MVS For Small Systems Users; Lauzon


>> Download B233 MVS For Small Systems Users; Lauzon documenatation <<

Text preview - extract from the document
                                                                                        .:---
  SESSION REPORT                                                                        i@SHAREt;
                                                                                        -:......-=-
            61         B233             MVS For. Small SYstems Users                                  /GO                    The 3031-5 operates with MYT under VM/SP. The 3031-8
        SHARE NO.     SESSION NO.                                   SESSION TITLE               ATTENDANce
                                                                                                                   runs with MVS/SP 1.3 in native mode. We are in our last stages of
                    MVS Proiect                                      John Cotto                          CHP       an MVT to MVS conversion which should be completed by the end of
                                                                     SESSION CHAIRMAN                  INST.CODE
                                                                                                                   the year. At that time, both CPU's will run MVS/SP 1.3, with
                        PROJECT
                                                                                                                   plans for the larger machine to run under VM/SP.
         55 Merritt Blvd.   Trumbull, CT 06611               (203) 377-2300
                               SESSION CHAIR~N'S COMPANY. ADDRESS. and Ptl0NE NUMBER                                         Come September, the MVS machine will support 15 CICS
                                                                                                                   terminals for a Registrar's system, 15 TSO/SPF terminals for staff
                                                                                                                   program development, some 60 to 80 concurrent WYLBUR (ASCII)
                                    MVS FOR SMALL SYSTEMS USERS                                                    terminals for our academic community, as well as a half dozen
                                                                                                                   batch initiators. Currently, the WYLBUR terminals and half the
                                                                                                                   batch initiators are not being supported under MVS. They are
                                             Roger C. Lauzon                                                       presently on the 3031-5 under MVT along with 30 data base termi-
                                                                                                                   nals, more WYLBUR terminals, and other batch initiators.
                                             Computer Centre
                                             University of Windsor                                                           The 3031-8 was installed this summer. Before that time,
                                             Windsor, Ontario                                                      the 3031-5 ran VM/SP with MVT as the favoured production virtual
                                             Canada     N9B 3P4                                                    machine, and MVS/SP 1.3 as a 'quasi-production' system. This was
                                                (519) 253-4232, X 648                                              done only to expedite the conversion to MVS, and it is not a
                                                                                                                   recommended practice.

                                             Installation Code:            UOW
                                                                                                                   MVS USER EXPERIENCE
                                                MVS project                                                                   Currently, the 3031-8 supporting CICS, TSO/SPF and
                                                                                                                   batch initiators runs very well. The terminal response time is
....                                            Session B233
                                                August 25, 1983
                                                                                                                   excellent. Paging is at a minimum. But when we tried the same
                                                                                                                   functions on the 3031-5, the batch initiators affected the terminal
,....
00
                                                                                                                   response times quite dramatically. But we feel we could have
                                                                                                                   improved the situation somewhat if the disks were not so limited
            INTRODUCTION                                                                                           and would have been set up just for that MVS system, not for VM
                                                                                                                   and MVT as well. The difference of 3 megabytes of real memory
                      The University of Windsor is a small university with                                         was significantly apparent to us as well. Come September, when
            some 8,500 full-time and 4,500 part-time students. Almost all                                          we add all the concurrent WYLBUR terminals to MVS on the 3031-8
            academic and administrative computing is performed in one data                                         system, we feel we will have to back off most of the batch
            processing centre run by the Computer Centre department that is                                        initiators during the day shift to achieve good on-line response.
            open seven days a week, twenty-four hours a day.                                                       As well, our on-line usage is not only from 9AM - 5PM, since the
                                                                                                                   students use the WYLBUR terminals around the clock. To achieve
                      The Computer Centre is a small to intermediate size MVS                                      good on-line response, some other users, normally batch, must be
            user. This paper will describe the hardware and software environ-                                      cut back.
            ment in the Computer Centre, our experience with MVS, and our con-
            cerns as a small MVS user.                                                                                       When we ran both MVT and MVS under VM on the 3031-5,
                                                                                                                   the on-line response on MVS was terrible. Two major factors
                                                                                                                   affected this: we favoured MVT as our production machine, and
            ENVIRONMENT                                                                                            we could not run MVS in a V=R environment since we only had 5
                                                                                                                   megabytes of real memory. Once we tried running MVS in a 4
                      We currently have two IBM 3031's, one with 5 megabytes                                       megabyte V=R area, which allowed fairly good response on the
            and the other one with 8 megabytes of memory. They eaph have                                           MVS side, but MVT died.
            three strings of DASD, all 3350 technology except one string of
            3330-11's which can be sharable but normally is not.  Disk stor-
            age is limited; for one CPU we have 4,400 megabytes, whereas the                                       CONCERNS AS A SMALL USER
            other contains 4,800 megabytes. Both CPU's share



◦ Jabse Service Manual Search 2024 ◦ Jabse PravopisonTap.bg ◦ Other service manual resources online : FixyaeServiceinfo