Text preview - extract from the document
                                                                                                     MX-DVB10




             SERVICE MANUAL
          COMPACT COMPONENT SYSTEM


                                  MX-DVB10                                                  Area suffix

                                                                                      US ------------- Singapore
                                                                                      UX ---------- Saudi Arabia
                                                                                      UN -------------------Asean




                           (SP-XSDVB10)           (SP-XCDVB10)            (SP-XSDVB10)
                                REAR                CENTER                     REAR




        (SP-XDVB10)         (SP-WDVB10)           (CA-MXDVB10)            (SP-WDVB10)             (SP-XDVB10)
          MAIN             SUBWOOFER                                     SUBWOOFER                   MAIN




Contents
Safety precautions                        1-2         Maintenance of laser pickup                      1-34
Preventing static electricity             1-3         Replacement of laser pickup                      1-34
Precautions for service                   1-4         Flow of functional operation
Important for laser products              1-5                        until TOC read                    1-35
Disassembly method                        1-6         Description of major ICs                         1-36~70
Adjustment method                         1-26


                                                                                                            No.21120
                            COPYRIGHT     2002 VICTOR COMPANY OF JAPAN, LTD.                                Sep. 2002
 MX-DVB10




        1. This design of this product contains special hardware and many circuits and components specially for safety
           purposes. For continued protection, no changes should be made to the original design unless authorized in
           writing by the manufacturer. Replacement parts must be identical to those used in the original circuits. Services
           should be performed by qualified personnel only.
        2. Alterations of the design or circuitry of the product should not be made. Any design alterations of the product
           should not be made. Any design alterations or additions will void the manufacturers warranty and will further
           relieve the manufacture of responsibility for personal injury or property damage resulting therefrom.
        3. Many electrical and mechanical parts in the products have special safety-related characteristics. These
           characteristics are often not evident from visual inspection nor can the protection afforded by them necessarily
           be obtained by using replacement components rated for higher voltage, wattage, etc. Replacement parts which
           have these special safety characteristics are identified in the Parts List of Service Manual. Electrical
           components having such features are identified by shading on the schematics and by ( ) on the Parts List in
           the Service Manual. The use of a substitute replacement which does not have the same safety characteristics
           as the recommended replacement parts shown in the Parts List of Service Manual may create shock, fire, or
           other hazards.
        4. The leads in the products are routed and dressed with ties, clamps, tubings, barriers and the like to be
           separated from live parts, high temperature parts, moving parts and/or sharp edges for the prevention of
           electric shock and fire hazard. When service is required, the original lead routing and dress should be
           observed, and it should be confirmed that they have been returned to normal, after re-assembling.
        5. Leakage current check (Electrical shock hazard testing)
           After re-assembling the product, always perform an isolation check on the exposed metal parts of the product
           (antenna terminals, knobs, metal cabinet, screw heads, headphone jack, control shafts, etc.) to be sure the
           product is safe to operate without danger of electrical shock.
           Do not use a line isolation transformer during this check.
             Plug the AC line cord directly into the AC outlet. Using a "Leakage Current Tester", measure the leakage
             current from each exposed metal parts of the cabinet, particularly any exposed metal part having a return
             path to the chassis, to a known good earth ground. Any leakage current must not exceed 0.5mA AC (r.m.s.).
             Alternate check method
             Plug the AC line cord directly into the AC outlet. Use an AC voltmeter having, 1,000 ohms per volt or more
             sensitivity in the following manner. Connect a 1,500 10W resistor paralleled by a 0.15 F AC-type capacitor
             between an exposed metal part and a known good earth ground.                             AC VOLTMETER
             Measure the AC voltage across the resistor with the AC                                   (Having 1000
             voltmeter.                                                                               ohms/volts,
                                                                                                      or more sensitivity)
             Move the resistor connection to each exposed metal part,
             particularly any exposed metal part having a return path to
                                                                                        0.15 F AC TYPE
             the chassis, and measure the AC voltage across the resistor.
             Now, reverse plug in the AC outlet and repeat each                                              Place this
                                                                                                             probe on
             measurement. Voltage measured any must not exceed 0.75 V                                        each exposed
             AC (r.m.s.). This corresponds to 0.5 mA AC (r.m.s.).                          1500 10W          metal part.

                                                                                                  Good earth ground


                                                                                                                       !
      1. This equipment has been designed and manufactured to meet international safety standards.              Burrs formed during molding may
      2. It is the legal responsibility of the repairer to ensure that these safety standards are maintained.   be left over on some parts of the
      3. Repairs must be made in accordance with the relevant safety standards.                                 chassis. Therefore, pay attention to
      4. It is essential that safety critical components are replaced by approved parts.                        such burrs in the case of
      5. If mains voltage selector is provided, check setting for local voltage.                                preforming repair of this system.

       In regard with component parts appearing on the silk-screen printed side (parts side) of the PWB diagrams, the
       parts that are printed over with black such as the resistor ( ), diode ( ) and ICP (     ) or identified by the " "
       mark nearby are critical for safety.
       (This regulation does not correspond to J and C version.)



1-2
                                                                                                                  MX-DVB10


Preventing static electricity
1. Grounding to prevent damage by static electricity
Electrostatic discharge (ESD), which occurs when static electricity stored in the body, fabric, etc. is discharged,
can destroy the laser diode in the traverse unit (optical pickup). Take care to prevent this when performing repairs.

2. About the earth processing for the destruction prevention by static electricity
In the equipment which uses optical pick-up (laser diode), optical pick-up is destroyed by the static electricity of
the work environment.
Be careful to use proper grounding in the area where repairs are being performed.

2-1 Ground the workbench
  Ground the workbench by laying conductive material (such as a conductive sheet) or an iron plate over
  it before placing the traverse unit (optical pickup) on it.

2-2 Ground yourself
  Use an anti-static wrist strap to release any static electricity built up in your body.



                           (caption)
                           Anti-static wrist strap


                                                                               Conductive material
                                                                               (conductive sheet) or iron plate

3. Handling the optical pickup
1. In order to maintain quality during transport and before installation, both sides of the laser diode on the
  replacement optical pickup are shorted. After replacement, return the shorted parts to their original condition.
 (Refer to the text.)

2. Do not use a tester to check the condition of the laser diode in the optical pickup. The tester's internal power
   source can easily destroy the laser diode.

4. Handling the traverse unit (optical pickup)
1. Do not subject the traverse unit (optical pickup) to strong shocks, as it is a sensitive, complex unit.

2. Cut off the shorted part of the flexible cable using nippers, etc. after replacing the optical pickup. For specific
   details, refer to the replacement procedure in the text. Remove the anti-static pin when replacing the traverse
   unit. Be careful not to take too long a time when attaching it to the connector.

3. Handle the flexible cable carefully as it may break when subjected to strong force.

4. It is not possible to adjust the semi-fixed resistor that adjusts the laser power. Do not turn it.




                                                                                                                         1-3
 MX-DVB10


  Precautions for service
      Handling of Traverse Unit and Laser Pickup

      1. Do not touch any peripheral element of the pickup or the actuator.
      2. The traverse unit and the pickup are precision devices and therefore must not be subjected to
         strong shock.
      3. Do not use a tester to examine the laser diode. (The diode can easily be destroyed by the
         internal power supply of the tester.)
      4. When replacing the pickup, after mounting a new pickup, remove the solder on the short land
         which is provided at the center of the flexible wire to open the circuit.
      5. Half-fixed resistors for laser power adjustment are adjusted in pairs at shipment to match the
         characteristics of the optical block.
         Do not change the setting of these half-fixed resistors for laser power adjustment.


      Destruction of Traverse Unit and Laser Pickup by Static Electricity

      Laser diodes are easily destroyed by static electricity charged on clothing
      or the human body. Before repairing peripheral elements of the traverse
      unit or pickup, be sure to take the following electrostatic protection:

      1. Wear an antistatic wrist wrap.
      2. With a conductive sheet or a steel plate on the workbench on which
         the traverse unit or the pick up is to be repaired, ground the sheet
         or the plate.

       When you remove the traverse mechanism from the servo control substrate
       The laser diode of pick-up might be destroyed by static electricity and set switch (S11) on the pick-up board
       on "SHORT" side, please before removing the card wire from connector (CN10).
       Moreover, please set switch (S11) on "OPEN" side after assembling and inserting the card wire in
       connector (CN10) without fail at times.

                                                    CN10                        SWITCH S11
           Traverse                                   CN12                          SHORT
         mechanism



                                                                                     OPEN



       When you remove the pick-up from the traverse mechanism
       The laser diode of the pick-up might be destroyed by static electricity. Before extracting
       the flexible wire from connector (CN12), please solder point A as shown below.
       Moreover, please remove solder in point A after inserting a flexible wire in connector (CN12).

                                                    Pick-up



                                                         Traverse
                                                         mechanism




                                            Soldering points A
1-4
                                                                                                                                                                   MX-DVB10


Important for laser products
 1. CLASS 1 LASER PRODUCT                                         5.CAUTION : If safety switches malfunction, the laser is able
 2. DANGER : Invisible laser radiation when open and inter          to function.
   lock failed or defeated. Avoid direct exposure to beam.        6.CAUTION : Use of controls, adjustments or performance of
 3. CAUTION : There are no serviceable parts inside the             procedures other than those specified herein may result in
   Laser Unit. Do not disassemble the Laser Unit. Replace           hazardous radiation exposure.
   the complete Laser Unit if it malfunctions.
  4.CAUTION : The compact disc player uses invisible laser
   radiation and is equipped with safety switches which             ! CAUTION Please use enough caution not to
                                                                              see the beam directly or touch it
   prevent emission of radiation when the drawer is open
                                                                              in case of an adjustment or operation
  and the safety interlocks have failed or are defeated. It is                check.
  dangerous to defeat the safety switches.



VARNING : Osynlig laserstr



◦ Jabse Service Manual Search 2024 ◦ Jabse PravopisonTap.bg ◦ Other service manual resources online : FixyaeServiceinfo