                                                                                       Model CA-554
Keithley Instruments, Inc.                                                   High-Voltage Triax Cable
28775 Aurora Road
Cleveland, Ohio 44139
1-888-KEITHLEY
http://www.keithley.com



Description
The Model CA-554 is a high-voltage triax cable assembly that is terminated on either end with a male high-voltage
triax connector.

                                             Figure 1: Model CA-554-.5




You can order the cable in four different lengths (see table below).

Model            Cable length
number
CA-554-.5        1.64 ft (0.5 m)
CA-554-1         3.28 ft (1.0 m)
CA-554-2         6.56 ft (2.0 m)
CA-554-3         9.84 ft (3.0 m)

This cable assembly can be used with the Models 2657A High Power System SourceMeterInstrument, 8010
High Power Device Test Fixture, 2657A-PM-200 External Protection Model, and 2657A-LIM-3 LO Interconnect
Module.




PA-1053 Rev. A / December 2011                                                                                  1
Model CA-554


Electrical characteristics
    Rated voltage: 3300 V
    Rated amperage: 2.0 A
    Leakage current:
        Center to guard: < 100 x 10-12 A at 3000 V (see NOTE below)
        Guard to shield: < 100 x 10-9 A at 3000 V
    Full continuity:
        Center to center
        Guard to guard
        Shield to shield
    Dielectric breakdown voltage:
        Center/guard to shield: 5250 V




             With the Model 2657A System SourceMeterInstrument, the voltage between the Guard and HI
             (inner shield and center conductor) will typically be less than 1 V under steady-state conditions. This
             results in much lower leakage current between the cable's inner shield and center conductor.