6. DOWNLOAD AND CALIBRATION



6. DOWNLOAD AND CALIBRATION

 6.1 Download
      Fig. 6-1 and 6-2 illustrate a download set-up.




                                       Figure 6-1. Download Setup 1.

     Download procedure
     Access flash loader program in PC.
     Select source code you want to download.
     Don't check OWCD AND VERIFY in flash loader window.
     Push start button in flash loader window.

     Condition
     1. Disconnect TA to the Datakit and phone have a battery
     a. VBAT < 3.2V
     Don't download to the phone.
     b. 3.2V    VBAT     3.4 V
     First : Connect Datakit to the phone.
     Second : Push the power on button until finish download.
     c. VBAT > 3.4V
     First : Connect Datakit to the phone.
     Second : Push the power on button during 1~2second.




                                              - 104 -
                                                    6. DOWNLOAD AND CALIBRATION



2. Connect TA to the Datakit and phone have a battery
a. VBAT < 3.2V
Don't download to the phone.
b. VBAT   3.2 V
Connect Datakit to the phone.

3. Download method when battery under 3.2 voltage
First : Remove battery in the phone
Second : Connect TA to the Datakit
Third : Connect phone to the Datakit.




                                Figure 6-2. Download Setup 2.




                                      - 105 -
6. DOWNLOAD AND CALIBRATION



 6.2 Calibration

   A. Equipment List
        Equipment for Calibration                   Type / Model                    Brand
        Wireless Communication Test Set             HP-8960                         Agilent
        RS-232 Cable and Test JIG                   LG
        RF Cable                                    LG
        Power Supply                                HP-66311B                       Agilent
        GPIB interface card                         HP-GPIB                         Agilent
        Calibration & Final test software           LG
        Test SIM Card
        PC (for Software Installation)              Pentium II class above 300MHz

                                   Table 6-1. Calibration Equipment List.

   B. Equipment Setup




                                         Figure 6-3. Equipment Setup.



                                              - 106 -
                                                    6. DOWNLOAD AND CALIBRATION




                           Figure 6-4. The top view of Test Jig.

C. Test Jig Operation


     Power Supply                            usually 4.0V
     DC Adaptor                              9.5V, 500mA

                                    Table 6-2. Jig Power.


     Switch Number      Name                 Description
     Switch 1           RPWRON               In ON state, phone is awaked.
     Switch 2           HF_DETECT            Turn on for AUDIO TEST
     Switch 3           Power Supply         Power is provided for phone from Power Supply
     Switch 4           D.C power            Power is provided for phone from DC adaptor.

                                Table 6-3. Jig DIP Switch.




                                       - 107 -
6. DOWNLOAD AND CALIBRATION



         Switch Number          Name                 Description
         Switch 1               RPWRON               In ON state, phone is awaked.
         Switch 2               HF_DETECT            Turn on for AUDIO TEST
         Switch 3               Power Supply         Power is provided for phone from Power Supply
         Switch 4               D.C power            Power is provided for phone from DC adaptor.

                                         Table 6-4. LED Description.

     1. Connect as Fig. 6-3.(RS232 Serial cable is connected between COM port of PC and MON port
       of TEST JIG, in general)
     2. Set the Power Supply 4.0 V, also DC adaptor may be used




     3. Set the 3rd of DIP SW ON state, In case of DC adapter, set 4th ON state
     4. Press the Phone power key, If the Remote ON is used, 1st ON state



   D. Procedure
     1. Connect as Fig. 6-3.(RS232 Serial cable is connected between COM port of PC and MON port
        of TEST JIG, in general)
     2. POWER ON PC then enter into Windows 98.(Remark: Windows 2000 system could be feasible)
     3. Run AUTOCAL.exe, then AUTOCAL application window will be appeared.




                                               - 108 -