Service Manuals, User Guides, Schematic Diagrams or docs for : LG TV Projector DU-52SZ61D PROJEÇÃO_TV_DU-52SZ61D

<< Back | Home

Most service manuals and schematics are PDF files, so You will need Adobre Acrobat Reader to view : Acrobat Download Some of the files are DjVu format. Readers and resources available here : DjVu Resources
For the compressed files, most common are zip and rar. Please, extract files with Your favorite compression software ( WinZip, WinRAR ... ) before viewing. If a document has multiple parts, You should download all, before extracting.
Good luck. Repair on Your own risk. Make sure You know what You are doing.




Image preview - the first page of the document
PROJEÇÃO_TV_DU-52SZ61D


>> Download PROJEÇÃO_TV_DU-52SZ61D documenatation <<

Text preview - extract from the document
                                CANADA : http//biz.lgservice.com
                                USA    : http//www.lgservice.com
                                       : http//lgservice.com/techsup.html




DLP PROJECTION TV
SERVICE MANUAL
CHASSIS : NB-04AA

MODEL : DU-52SZ61D
CAUTION
BEFORE SERVICING THE CHASSIS,
READ THE SAFETY PRECAUTIONS IN THIS MANUAL.
                                            SAFETY PRECAUTIONS

                                            IMPORTANT SAFETY NOTICE
 Many electrical and mechanical parts in this chassis have special safety-related characteristics. These parts are identified by in
 the Schematic Diagram and Replacement Parts List.
 It is essential that these special safety parts should be replaced with the same components as recommended in this manual to
 prevent X-RADIATION, Shock, Fire, or other Hazards.
 Do not modify the original design without permission of manufacturer.



General Guidance                                                      Leakage Current Hot Check (See below Figure)
                                                                      Plug the AC cord directly into the AC outlet.
An lsolation Transformer should always be used during                 Do not use a line Isolation Transformer during this check.
the servicing of a receiver whose chassis is not isolated from        Connect 1.5K/10watt resistor in parallel with a 0.15uF capacitor
the AC power line. Use a transformer of adequate power rating         between a known good earth ground (Water Pipe, Conduit, etc.)
as this protects the technician from accidents resulting in           and the exposed metallic parts.
personal injury from electrical shocks.                               Measure the AC voltage across the resistor using AC
                                                                      voltmeter with 1000 ohms/volt or more sensitivity.
It will also protect the receiver and it's components from being      Reverse plug the AC cord into the AC outlet and repeat AC
damaged by accidental shorts of the circuitary that may be            voltage measurements for each esposed metallic part. Any
inadvertently introduced during the service operation.                voltage measured must not exceed 0.75 volt RMS which is
                                                                      corresponds to 0.5mA.
If any fuse (or Fusible Resistor) in this monitor is blown, replace   In case any measurement is out of the limits sepcified, there is
it with the specified.                                                possibility of shock hazard and the set must be checked and
                                                                      repaired before it is returned to the customer.
When replacing a high wattage resistor (Oxide Metal Film
Resistor, over 1W), keep the resistor 10mm away from PCB.

Keep wires away from high voltage or high temperature parts.          Leakage Current Hot Check circuit

Due to high vacuum and large surface area of picture tube,
                                                                                            AC Volt-meter
extreme care should be used in handling the Picture Tube.
Do not lift the Picture tube by it's Neck.

                                                                                                                Good Earth Ground
                                                                                                                such as WATER PIPE,
Leakage Current Cold Check(Antenna Cold Check)                           To Instrument's                        CONDUIT etc.
With the instrument AC plug removed from AC source,                                               0.15uF
                                                                         exposed
connect an electrical jumper across the two AC plug prongs.              METALLIC PARTS
Place the AC switch in the on positioin, connect one lead of
ohm-meter to the AC plug prongs tied together and touch other
ohm-meter lead in turn to each exposed metallic parts such as                                 1.5 Kohm/10W
antenna terminals, phone jacks, etc.
If the exposed metallic part has a return path to the chassis, the
measured resistance should be between 1M and 5.2M.
When the exposed metal has no return path to the chassis the          CANADA: LG Electronics Canada, Inc. 550 Matheson
reading must be infinite.                                                     Boulevard East Mississauga, Ontario L4Z 4G3
An other abnormality exists that must be corrected before the
receiver is returned to the customer.                                 USA      : LG Customer Interactive Center
                                                                                  P.O.Box 240007, 201 James Record Road Huntsville,
                                                                                  AL 35824
                                                                                  Digital TV Hotline 1-800-243-0000




                                                                 - 2 -
                                                       TABLE OF CONTENTS

SPECIFICATIONS.................................................................4


DESCRIPTION OF CONTROLS ...........................................5


ADJUSTMENT INSTRUCTION.............................................8


PRINTED CIRCUIT BOARDS .............................................21


BLOCK DIAGRAM...............................................................31


EXPLODED VIEW...............................................................32


EXPLODED VIEW PARTS LIST .........................................33


REPLACEMENT PARTS LIST ............................................34


SCHEMATIC DIAGRAM..........................................................




                                                                               - 3 -
                                       SPECIFICATIONS


        MODELS                                      DU-52SZ51D / DU-52SZ61D

    Power requirement                                         AC120V, 60Hz

    Television System                                        NTSC-M, ATSC

    Program Coverage                 VHF 2 ~ 13, UHF 14 ~ 69, CATV 1 ~ 135, CADTV 1 ~ 135. DTV 2 ~ 69

External Antenna Impedance                                        75 




   



◦ Jabse Service Manual Search 2024 ◦ Jabse PravopisonTap.bg ◦ Other service manual resources online : FixyaeServiceinfo