Service Manuals, User Guides, Schematic Diagrams or docs for : LG TV Projector RT-60SZ31RB lg-rt60sz31rb_112

<< Back | Home

Most service manuals and schematics are PDF files, so You will need Adobre Acrobat Reader to view : Acrobat Download Some of the files are DjVu format. Readers and resources available here : DjVu Resources
For the compressed files, most common are zip and rar. Please, extract files with Your favorite compression software ( WinZip, WinRAR ... ) before viewing. If a document has multiple parts, You should download all, before extracting.
Good luck. Repair on Your own risk. Make sure You know what You are doing.




Image preview - the first page of the document
lg-rt60sz31rb_112


>> Download lg-rt60sz31rb_112 documenatation <<

Text preview - extract from the document
                                                                                                   website:http://biz.LGservice.com
                                                                                   e-mail:http://www.LGEservice.com/techsup.html




                                        LCD Projection TV
                                        SERVICE MANUAL
                                        CHASSIS : MB-03CB

                                        MODEL : RT-52/60SZ31RB/RP
                                        CAUTION
                                        BEFORE SERVICING THE CHASSIS,
                                        READ THE SAFETY PRECAUTIONS IN THIS MANUAL.




                           Oct.,2003
P/NO : 3828VD0133Z   Printed in Korea      TV/AV   MENU   OK   VOL   PR   ON/OFF
                                                    CONTENTS



CONTENTS ..................................................................................................................... 2

SAFETY PRECAUTIONS ................................................................................................3

SERVICING PRECAUTIONS .......................................................................................... 4

CONTROL DESCRIPTIONS ............................................................................................6

SPECIFICATIONS ..........................................................................................................10

ADJUSTMENT INSTRUCTIONS ....................................................................................14

BLOCK DIAGRAM..........................................................................................................20

PRINTED CIRCUIT BOARD ...........................................................................................25

EXPLODED VIEW .................................................................................................... 34,36

EXPLODED VIEW PARTS LIST ................................................................................35,37

REPLACEMENT PARTS LIST .......................................................................................38

SVC. SHEET ......................................................................................................................




                                                            - 2 -
                                          SAFETY PRECAUTIONS

                                           I M P O RTANT SAFETY NOTICE
 Many electrical and mechanical parts in this chassis have special safety-related characteristics. These parts are identified by in
 the Schematic Diagram and Replacement Parts List.
 It is essential that these special safety parts should be replaced with the same components as recommended in this manual to
 prevent X-RADIATION, Shock, Fire, or other Hazards.
 Do not modify the original design without permission of manufacturer.



General Guidance                                                    Leakage Current Cold Check(Antenna Cold Check)
                                                                    With the instrument AC plug removed from AC source,
An lsolation Transformer should always be used during               connect an electrical jumper across the two AC plug prongs.
the servicing of a receiver whose chassis is not isolated from      Place the AC switch in the on position, connect one lead of
the AC power line. Use a transformer of adequate power rating       ohm-meter to the AC plug prongs tied together and touch other
as this protects the technician from accidents resulting in         ohm-meter lead in turn to each exposed metallic parts such as
personal injury from electrical shocks.                             antenna terminals, phone jacks, etc.
                                                                    If the exposed metallic part has a return path to the chassis, the
It will also protect the receiver and it's components from being    measured resistance should be between 1M and 5.2M.
damaged by accidental shorts of the circuitry that may be           When the exposed metal has no return path to the chassis the
inadvertently introduced during the service operation.              reading must be infinite.
                                                                    An other abnormality exists that must be corrected before the
If any fuse (or Fusible Resistor) in this TV receiver is blown,     receiver is returned to the customer.
replace it with the specified.
                                                                    Leakage Current Hot Check (See below Figure)
When replacing a high wattage resistor (Oxide Metal Film            Plug the AC cord directly into the AC outlet.
Resistor, over 1W), keep the resistor 10mm away from PCB.           Do not use a line Isolation Transformer during this check.
                                                                    Connect 1.5K/10watt resistor in parallel with a 0.15uF capacitor
Keep wires away from high voltage or high temperature parts.        between a known good earth ground (Water Pipe, Conduit, etc.)
                                                                    and the exposed metallic parts.
Due to high vacuum and large surface area of picture tube,          Measure the AC voltage across the resistor using AC
extreme care should be used in handling the Picture Tube.           voltmeter with 1000 ohm/volt or more sensitivity.
Do not lift the Picture tube by it's Neck.                          Reverse plug the AC cord into the AC outlet and repeat AC
                                                                    voltage measurements for each exposed metallic part. Any
Before returning the receiver to the customer,                      voltage measured must not exceed 0.75 volt RMS which is
                                                                    corresponds to 0.5mA.
always perform an AC leakage current check on the exposed           In case any measurement is out of the limits specified, there is
metallic parts of the cabinet, such as antennas, terminals, etc.,   possibility of shock hazard and the set must be checked and
to be sure the set is safe to operate without damage of             repaired before it is returned to the customer.
electrical shock.
                                                                    Leakage Current Hot Check circuit

                                                                                           AC Volt-meter




                                                                                                               Good Earth Ground
                                                                                                               such as WATER PIPE,
                                                                       To Instrument's                         CONDUIT etc.
                                                                                                 0.15uF
                                                                       exposed
                                                                       METALLIC PARTS


                                                                                             1.5 Kohm/10W




                                                               - 3 -
                                         S E RVICING PRECAUTIONS
CAUTION: Before servicing receivers covered by this service          transistors and semiconductor "chip" components. The
manual and its supplements and addenda, read and follow the          following techniques should be used to help reduce the
SAFETY PRECAUTIONS on page 3 of this publication.                    incidence of component damage caused by static by static
NOTE: If unforeseen circumstances create conflict between the        eetiiy
                                                                      lcrct.
following servicing precautions and any of the safety                1 Immediately before handling any semiconductor component
                                                                     .
precautions on page 3 of this publication, always follow the            or semiconductor-equipped assembly, drain off any
safety precautions. Remember: Safety First.                             electrostatic charge on your body by touching a known earth
                                                                        ground. Alternatively, obtain and wear a commercially
General Servicing Precautions                                           available discharging wrist strap device, which should be
1 Always unplug the receiver AC power cord from the AC
.                                                                       removed to prevent potential shock reasons prior to
   power source before;                                                 applying power to the unit under test.
   a Removing or reinstalling any component, circuit board
   .                                                                 2 After removing an electrical assembly equipped with ES
                                                                     .
      module or any other receiver assembly.                            devices, place the assembly on a conductive surface such as
   b Disconnecting or reconnecting any receiver electrical plug
    .                                                                   aluminum foil, to prevent electrostatic charge buildup or
      or other electrical connection.                                   exposure of the assembly.
   c Connecting a test substitute in parallel with an electrolytic
   .                                                                 3 Use only a grounded-tip soldering iron to solder or unsolder
                                                                     .
      capacitor in the receiver.                                        ES devices.
      CAUTION: A wrong part substitution or incorrect                4 Use only an anti-static type solder removal device. Some
                                                                     .
      polarity installation of electrolytic capacitors may result       solder removal devices not classified as "anti-static" can
      in an explosion hazard.                                           generate electrical charges sufficient to damage ES devices.
   d Discharging the picture tube anode.
    .                                                                5 Do not use freon-propelled chemicals. These can generate
                                                                     .
2 Test high voltage only by measuring it with an appropriate
.                                                                       electrical charges sufficient to damage ES devices.
   high voltage meter or other voltage measuring device (DVM,        6 Do not remove a replacement ES device from its protective
                                                                     .
   FETVOM, etc) equipped with a suitable high voltage probe.            package until immediately before you are ready to install it.
   Do not test high voltage by "drawing an arc".                        (Most replacement ES devices are packaged with leads
3 Discharge the picture tube anode only by (a) first connecting
.                                                                       electrically shorted together by conductive foam, aluminum
   one end of an insulated clip lead to the degaussing or kine          foil or comparable conductive material).
   aquadag grounding system shield at the point where the            7 Immediately before removing the protective material from
                                                                     .
   picture tube socket ground lead is connected, and then (b)           the ieads of a replacement ES device, touch the protective
   touch the other end of the insulated clip lead to the picture        material to the chassis or circuit assembly into which the
   tube anode button, using an insulating handle to avoid               device will be installed.
   personal contact with high voltage.                                  CAUTION:Be sure no power is applied to the chassis or
4 Do not spray chemicals on or near this receiver or any of its
.                                                                       circuit, and observe all other safety precautions.
   assemblies.                                                       8 Minimize bodily motions when handling unpackaged
                                                                     .
5 Unless specified otherwise in this service manual, clean
.                                                                       replacement ES devices. (Otherwise harmless motion such
   electrical contacts only by applying the following mixture to        as the brushing together of your clothes fabric or the lifting
   the contacts with a pipe cleaner, cotton-tipped stick or             of your foot from a carpeted floor can generate static
   comparable nonabrasive applicator; 10% (by volume)                   electricity sufficient to damage an ES device.)
   Acetone and 90% (by volume) isopropyl alcohol (90%-99%
   strength)                                                         General Soldering Guidelines
   CAUTION: This is a flammable mixture.                             1 Use a grounded-tip, low-wattage soldering iron and
                                                                     .
   Unless specified otherwise in this service manual, lubrication       appropriate tip size and shape that will maintain tip
   of contacts in not required.                                         temperature within the range or 500



◦ Jabse Service Manual Search 2024 ◦ Jabse PravopisonTap.bg ◦ Other service manual resources online : FixyaeServiceinfo