Text preview - extract from the document
                      CONFIDENTIAL

                      Issue: 8. Apr .05

                      Version: 1.0




42" PDP
SERVICE MANUAL
MODELBDH4222V/00,BDH4222V/22
        BDH4223V/27
PANELVVFPF42C128UC51




                         Collation: Andy Lai
                      CONTENTS

1. IMPORTANT SAFETY PRECAUTIONS                       ........1-2


2. BLOCK DIAGRAM           ...................................2-5


3. FACTORY & ELECTRONIC ADJUSTMENT ..3-1


4. TROUBLE SHOOTING GUIDES                   .................4-7


5. SPECIFICATION         .....................................5-8


6. P.C. BOARD TOP VIEW            ...........................6-7


7. ELECTRONIC MODULES LIST ..................7-1


8. EXPLODED VIEW           ...................................8-1


9. PACKING OF THE LIST ............................9-1




        If having any changes, do not do advanced advice.
SAFETY PRECAUTIONS                                                                                VER1.0

1. Before returning an instrument to the customer, always make a safety check of the entire instrument,
   including, but not limited to, the following items.
a. Be sure that no built-in protective devices are defective and/or have been defeated during servicing. (1)
   Protective shields are provided on this chassis to protect both the technician and the customer. Correctly
   replace all missing protective shields, including any removed for servicing convenience. (2) When
   reinstalling the chassis and/or other assembly in the cabinet, be sure to put back in place all protective
   devices, including, but not limited to, nonmetallic control knobs, insulating fishpapers, adjustment and
   compartment covers/shields, and isolation resistor/capacitor networks. Do not operate this instrument
   or permit it to be operated without all protective devices correctly installed and functioning.
b. Be sure that there are no cabinet openings through which an adult or child might be able to insert their
   fingers and contact a hazardous voltage, Such opening include, but are not limited to, (1) spacing
   between the picture tube and the cabinet mask, (2) excessively wide cabinet ventilation slots, and (3) an
   improperly fitted and/or incorrectly secured cabinet back cover.
c. Leakage Current Hot Check--With the instrument completely reassembled, plug the AC line cord directly
   into a 120V AC outlet. (Do not use an isolation transformer during this test.) Use a leakage current tester
   or a metering system that complies with American National Standards Institutes (ANSI) C101.1 Leakage
   Current for Appliances and Underwriters Laboratories (UL) 478. With the instrument AC switch first in the
   ON position and then in the OFF position, measure from a known earth ground (metal waterpipe, conduit,
   etc.) to all exposed metal parts of the instrument (antennas, handle bracket, metal cabinet, screwheads,
   metallic overlays, control shafts, etc.), especially any exposed metal parts that offer an electrical return
   path to the chassis. Any current measured must not exceed 3.5 milliamp. Reverse the instrument power
   cord plug in the outlet and repeat test. ANY MEASUREMENTS NOT WITHIN THE LIMITS SPECIFIED
   HEREIN INDICATE A POTENTIAL SHOCK HAZARD THAT MUST BE ELIMINATED BEFORE
   RETURNING THE INSTRUMENT TO THE CUSTOMER.


                                AC Leakage Test                            (READING
                                                                          SHOULD NOR
                                                                           BE ABOVE
                                                                LEAKAGE      3.5mA)
                                                                CURRENT
                                                                 TESTER

                                       DEVICE
                                       UNDER                     + -
                                        TEST

                                                TEST ALL
                                                EXPOSED METAL
                                                SURFACES

                                           3. WIRE CORD

                                         ALSO TEST WITH
                                         PLUG REVERSED                         EARTH
                                         (USING AC ADAPTER                    GROUND
                                         PLUG AS REQUIRED)




2. Read and comply with all caution and safety-related notes on or inside the Monitor cabinet, on the
   Projection Monitor chassis, or on the picture tube.
3. Design Alteration Warning--Do not alter or add to the mechanical or electrical design of this unit. Design
   alterations and additions, including, but not limited to, circuit modifications and the addition of the items
   such as auxiliary audio and/or video output connections might alter the safety characteristics of this
   Projection Monitor and create a hazard to the user. Any design alterations or additions will void the
   manufacturer's warranty and will make you, the service, responsible for personal injury or property
   damage resulting therefrom.




                                                          1-1
SAFETY PRECAUTIONS                                                                               VER1.0

4. Hot Chassis Warning--a. Some Monitor chassis are electrically connected directly to one conductor of
   the AC power cord and may be safely serviced without an isolation transformer only if the AC power plug
   is inserted so that the chassis is connected to the ground side of the AC power source. To confirm that the
   AC power plug is inserted correctly, with an AC voltmeter measure between the chassis and a known
   earth ground. If a voltage reading in excess of 1.0V is obtained, remove and reinsert the AC power plug in
   opposite polarity and again measure the voltage potential between the chassis and a known earth ground.
   b. Some Monitor chassis normally have 85V AC (RMS.), between chassis and earth ground regardless of
   the AC plug polarity. These chassis can be safely serviced only with an isolation transformer inserted in
   the power line between the receiver and the AC power source, for both personnel and test equipment
   protection. c. Some Projection Monitor chassis have a secondary ground systems in addition to the main
   chassis ground. This secondary ground system is not isolated from the AC power line. The two ground
   system are electrically separated by insulating material that must not be defeated or altered.

5. Observe original lead dress. Take extra care to assure correct lead dress in the following areas: a. near
   sharp edges, b. near thermally hot parts--be sure that leads and components do not touch thermally hot
   parts, c. the AC supply, d. high voltage, e. antenna wiring. Always inspect in all areas for pinched,
   out-of-place, or frayed wiring. Do not change spacing between components, and between components
   and the printed-circuit board. Check AC power cord for damage.

6. Components, parts, and/or wiring that appear to have overheated or are otherwise damaged should be
   replaced with components, parts, or wireing that meet original specifications. Additionally, determine the
   cause of overheating and/or damage and, if necessary, take corrective action to remove any potential
   safety hazard.

7. PRODUCT SAFETY NOTICE--Many Monitor electrical and mechanical parts have special safety-related
   characteristics some of which are often not evident from visual inspection, nor can the protection they give
   necessarily be obtained by replacing them with components rated for higher voltage, wattage, etc. Parts
   that have special safety characteristics are identified in this service data by shading with a      mark on
   schematics and by shading or a  mark in the parts list. Use of a substitute replacement part that does
   not have the same safety characteristics as the recommended replacement part in this service data parts
   list might create shock, fire, and/or other hazards.




                                                     1-2
BLOCK DIAGRAM                                                                                                                                                                                      VER1.0

                                                                                 PDP Panel Module




                Y Amp Board-Upper Ass'y




                                                                                                                                                                         X Amp Board-Upper Ass'y
                                                                                                                JA 1
                                                                        SUB-Power             Audio
                                                                        Board Ass'y           Amplifier   JA 2
                                                                    J10                       Board Ass'y




                                                                    PANEL Power Supply
                                                                    Ass'y                                                   Interface
                                           Interface                                                                        Board- X Ass'y
                                           Board- Y Ass'y
                Y Amp Board-Lower Ass'y




                                                                                                                                                                         X Amp Board-Lower Ass'y
                                                                                                    CN2
                                                                          Logic Board Ass'y
                                                                                                    CN8
                                                                Image Board Ass'y
                                                                                 CN5    CN15
                                                                AV Module
 Front Button
                                                                Board                               CN6   CN7

 Control                                                        Ass'y  CN4
                                                                                                   CN14
 Board Ass'y
        JA3                                                                                        J5
                                                                 CN13




                                          Address BUS-L Ass'y                                                          Address BUS-R Ass'y




                                                                                                                              Pa ne l's B oa rd Assem b ly   S AM P O Bo ard A ssem bl y




                                                                                        2-1
BLOCK DIAGRAM                                                                                                                                                                                     VER1.0
                                                                                     Image Board Socket Data
             Im age Board 



◦ Jabse Service Manual Search 2024 ◦ Jabse PravopisonTap.bg ◦ Other service manual resources online : FixyaeServiceinfo