>> Download ST-01-0017 documenatation <<Text preview - extract from the documentFine adjustment of VG2
1. Select the picture source to an AV input without any connection to any source
2. Measure the RGB signal at cathode of picture tube after the TV set ON for at least
10 min. Oscilloscope time base set to 200us with external trigger on the vertical
pulse.
3. Choose one of the gun with the max. amplitude and adjust the Vcutoff voltage as
shown;
max.
Vcutoff = 165Vdc
0V Ref.