ST-01-0017


>> Download ST-01-0017 documenatation <<

Text preview - extract from the document
Fine adjustment of VG2

1.       Select the picture source to an AV input without any connection to any source
2.       Measure the RGB signal at cathode of picture tube after the TV set ON for at least
         10 min. Oscilloscope time base set to 200us with external trigger on the vertical
         pulse.
3.       Choose one of the gun with the max. amplitude and adjust the Vcutoff voltage as
         shown;




                 max.

                                   Vcutoff = 165Vdc


     0V Ref.