Service Manuals, User Guides, Schematic Diagrams or docs for : Rohde & Schwarz R&S FSEA 20 R+S FSEA 20 serv

<< Back | Home

Most service manuals and schematics are PDF files, so You will need Adobre Acrobat Reader to view : Acrobat Download Some of the files are DjVu format. Readers and resources available here : DjVu Resources
For the compressed files, most common are zip and rar. Please, extract files with Your favorite compression software ( WinZip, WinRAR ... ) before viewing. If a document has multiple parts, You should download all, before extracting.
Good luck. Repair on Your own risk. Make sure You know what You are doing.




Image preview - the first page of the document
R+S FSEA 20 serv


>> Download R+S FSEA 20 serv documenatation <<

Text preview - extract from the document
                                      Test and
                                      Measurement Division




               Service Manual Instrument



               SPECTRUM ANALYZER
               FSEA20/30
               1065.6000.20/.25/35

               FSEB20/30
               1066.3010.20/.25/35

               FSEM20/30
               1080.1505.20/.21/.25
               1079.8500.30/.31/.35

               FSEK20/30
               1088.1491.20/.21/.25
               1088.3494.30/.31/.35




Printed in the Federal
Republic of Germany



1065.6016.82-14-
FSE                                                          Tabbed Divider Overview


Tabbed Divider Overview

Index

Safety Instructions

Certificate of Quality

Spare Parts Express Service
List of R&S Representatives

Contents of Manuals for Signal Analyzer
Service and Repair


Tabbed Divider


        1                Chapter 1:       Performance Test

        2                Chapter 2:       Adjustment

        3                Chapter 3:       Functional Description/Selftest

        4                Chapter 4:       Firmware Update/Options

        5                Chapter 5:       Documents




1065.6016.82                                  RE                                  E-1
FSE                                                                                                                                                                      Index


Index

1                                                                                              N
    st
1 IF Image Frequency Rejection ...................................1.7                          Noise Display ............................................................... 1.15
1st IF Rejection ...............................................................1.8            Non-linearities ................................................................ 1.9

2                                                                                              O
    nd
2        IF Image Frequency Rejection ..................................1.8                    Option
                                                                                                   1-dB Attenuator - FSE-B13 ...................................... 4.2
3                                                                                                  2nd IEC/IEEE Bus Interface - FSE-B17 .................... 4.2
                                                                                                   Ethernet Interface - FSE-B16................................... 4.2
3-dB Bandwidths ..........................................................1.13
                                                                                                   External Mixer Output - FSE-B21............................. 4.2
A                                                                                                  Installation ............................................................... 4.2
                                                                                                   List........................................................................... 4.2
Adjustment .....................................................................2.1                Tracking Generator - FSE-B10/B11 ......................... 4.2
Attenuator.....................................................................1.19            Ordering of spare parts .................................................. 5.1
    Option FSE-B22 .....................................................1.46                   Output Level
                                                                                                   Tracking Generator ................................................ 1.24
C
                                                                                               P
Cable list.........................................................................5.3
Calibration Source at 120 MHz .......................................1.3                       Performance Test Report ............................................. 1.26
    Option FSE-B22 .....................................................1.41                       Option FSE-B22..................................................... 1.47
Checking the Rated Specifications .................................1.1                         Phase Noise................................................................. 1.22
Circuit diagram ...............................................................5.5             Power cables ................................................................. 5.3

D                                                                                              R
Display Linearity ...........................................................1.18              Rated Specifications ...................................................... 1.1
    Option FSE-B22 .....................................................1.45                   Replacement parts
Documents .....................................................................5.1                ordering ................................................................... 5.2
                                                                                               Return Loss at the RF Input ........................................... 1.5
F
                                                                                               S
Firmware update.............................................................4.1
Frequency Accuracy of the Reference Oscillator ............1.4                                 Second-Order Harmonic Distortion............................... 1.10
Frequency Response....................................................1.16                     Self test.......................................................................... 3.6
    Option FSE-B22 .....................................................1.43                   Shape Factor ............................................................... 1.14
    Tracking Generator.................................................1.24                    Shipping
                                                                                                   instrument ................................................................ 5.1
I                                                                                                  module..................................................................... 5.1
                                                                                               Softkey
I/Q Modulator
                                                                                                   FIRMWARE UPDATE.............................................. 4.1
    Tracking Generator.................................................1.25
                                                                                                   RESTORE FIRMWARE ........................................... 4.1
IF Filters .......................................................................1.12
                                                                                               Software
    Option FSE-B22 .....................................................1.42
                                                                                                   installation................................................................ 4.1
IF Gain Switching .........................................................1.20
                                                                                                   update...................................................................... 4.1
Imunity to Interference ....................................................1.7
                                                                                               Spare parts
L                                                                                                  ordering ................................................................... 5.1

Level Error....................................................................1.12            T
   Option FSE-B22 .....................................................1.42
                                                                                               Test Instructions............................................................. 1.3
LO Feedthrough............................................................1.15
                                                                                                   Option FSE-B22..................................................... 1.41
M                                                                                              Third-Order Intercept...................................................... 1.9
                                                                                               Tracking Generator ...................................................... 1.24
Measuring Equipment .....................................................1.1




1065.6016.82                                                                             I.1                                                                                   E-2
                                                  Safety Instructions

      This unit has been designed and tested in accordance with the EC Certificate of Conformity and has left the
      manufacturer's plant in a condition fully complying with safety standards.
      To maintain this condition and to ensure safe operation, the user must observe all instructions and warnings
      given in this operating manual.

      Safety-related symbols used on equipment and documentation from R&S:




  Observe         Weight        PE terminal        Ground          Danger!            Warning!          Ground          Attention!
 operating     indication for                      terminal      Shock hazard        Hot surfaces                     Electrostatic
instructions    units >18 kg                                                                                          sensitive de-
                                                                                                                      vices require
                                                                                                                      special care

      1.   The unit may be used only in the operating con-           7.   It is not permissible to interrupt the PE conduc-
           ditions and positions specified by the manufac-                tor intentionally, neither in the incoming cable
           turer. Unless otherwise agreed, the following                  nor on the unit itself as this may cause the unit
           applies to R&S products:                                       to become electrically hazardous.
           IP degree of protection 2X, pollution severity 2               Any extension lines or multiple socket outlets
           overvoltage category 2, only for indoor use, al-               used must be checked for compliance with rele-
           titude max. 2000 m.                                            vant safety standards at regular intervals.
           The unit may be operated only from supply net-            8.   If the unit has no power switch for disconnection
           works fused with max. 16 A.                                    from the AC supply, the plug of the connecting
           Unless specified otherwise in the data sheet, a                cable is regarded as the disconnecting device.
           tolerance of 10% shall apply to the nominal                    In such cases it must be ensured that the power
           voltage and of 5% to the nominal frequency.                    plug is easily reachable and accessible at all
      2.   For measurements in circuits with voltages Vrms                times (length of connecting cable approx. 2 m).
           > 30 V, suitable measures should be taken to                   Functional or electronic switches are not suit-
           avoid any hazards.                                             able for providing disconnection from the AC
                                                                          supply.
           (using, for example, appropriate measuring
           equipment, fusing, current limiting, electrical                If units without power switches are integrated in
           separation, insulation).                                       racks or systems, a disconnecting device must
                                                                          be provided at system level.
      3.   If the unit is to be permanently wired, the PE
           terminal of the unit must first be connected to           9.   Applicable local or national safety regulations
           the PE conductor on site before any other con-                 and rules for the prevention of accidents must
           nections are made. Installation and cabling of                 be observed in all work performed.
           the unit to be performed only by qualified techni-             Prior to performing any work on the unit or
           cal personnel.                                                 opening the unit, the latter must be discon-
                                                                          nected from the supply network.
      4.   For permanently installed units without built-in
                                                                          Any adjustments, replacements of parts, main-
           fuses, circuit breakers or similar protective de-
                                                                          tenance or repair may be carried out only by
           vices, the supply circuit must be fused such as
                                                                          authorized R&S technical personnel.
           to provide suitable protection for the users and
           equipment.                                                     Only original parts may be used for replacing
                                                                          parts relevant to safety (eg power switches,
      5.   Prior to switching on the unit, it must be ensured             power transformers, fuses). A safety test must
           that the nominal voltage set on the unit matches               be performed after each replacement of parts
           the nominal voltage of the AC supply network.                  relevant to safety.
           If a different voltage is to be set, the power fuse            (visual inspection, PE conductor test, insulation-
           of the unit may have to be changed accordingly.                resistance, leakage-current measurement, func-
      6.   Units of protection class I with disconnectible                tional test).
           AC supply cable and appliance connector may                                                  continued overleaf
           be operated only from a power socket with
           earthing contact and with the PE conductor con-
           nected.




      1065.6016.82                                            SI.1                                                     E-2
                                                          Safety Instructions

10. Ensure that the connections with information                          13. Electrostatics via the connectors may dam-
    technology equipment comply with IEC950 /                                 age the equipment. For the safe handling and
    EN60950.                                                                  operation of the equipment,          appropriate
11. Lithium batteries must not be exposed to high                             measures against electrostatics should be im-
    temperatures or fire.                                                     plemented.
    Keep batteries away from children.                                    14. The outside of the instrument is suitably
    If the battery is replaced improperly, there is                           cleaned using a soft, lint-free dustcloth. Never
    danger of explosion. Only replace the battery by                          use solvents such as thinners, acetone and
    R&S type (see spare part list).                                           similar things, as they may damage the front
    Lithium batteries are suitable for environmen-                            panel labeling or plastic parts.
    tally-friendly disposal or specialized recycling.                     15. Any additional safety instructions given in this
    Dispose them into appropriate containers, only.                           manual are also to be observed.
    Do not short-circuit the battery.
12. Equipment returned or sent in for repair must be
    packed in the original packing or in packing with
    electrostatic and mechanical protection.


The instrument contains components which are hazardous to electrostatic exposure and which are marked by the
following symbol:







◦ Jabse Service Manual Search 2024 ◦ Jabse PravopisonTap.bg ◦ Other service manual resources online : FixyaeServiceinfo