Service Manuals, User Guides, Schematic Diagrams or docs for : Tektronix 7B92A Dual Time Base (Oscilloscope Plugin) (1975) WW

<< Back | Home

Most service manuals and schematics are PDF files, so You will need Adobre Acrobat Reader to view : Acrobat Download Some of the files are DjVu format. Readers and resources available here : DjVu Resources
For the compressed files, most common are zip and rar. Please, extract files with Your favorite compression software ( WinZip, WinRAR ... ) before viewing. If a document has multiple parts, You should download all, before extracting.
Good luck. Repair on Your own risk. Make sure You know what You are doing.




Image preview - the first page of the document
7B92A Dual Time Base (Oscilloscope Plugin) (1975) WW


>> Download 7B92A Dual Time Base (Oscilloscope Plugin) (1975) WW documenatation <<

Text preview - extract from the document
                            TEKTRONIX



                            INSTRUCTION MANUAL
Tektronix, Inc .
P .O . Box 500
Beaverton, Oregon   97077         Serial Number


070-1752-01                                       First Printing DEC 1974
                                      are warranted,
                                       ship, for one year . i',o-, y
questions                    ~ry ,.farranty should be taken up
with your   Ti   Ell,    He~rj F-igineer or representative .



All requests IL -
directed to znp
in your area,             assure you he lastesi
service . Please icOLidle the. instrument Type             or
P-ri' Number arm Seiia! Number with all -~-quesls l(, . parts
or service .



Specifications and price change privileges reserved .



Copyright , 1974, new material 1975, by Tektronix, Inc .,
Beaverton, Oregon . Printed in the United States of
America . All rights reserved . Contents of this publication
may not be reproduced in any form without permission of
Tektronix, Inc .



U .S .A . and foreign Tektronix products covered by U .S .
and foreign patents and/or patents pending .



TEKTRONIX is a registered trademark of Tektronix, Inc .
                                                                                                7B92A Operators




                                              TABLE OF CONTENTS
                                                                                         PAGE

                List of Illustrations                                                     ii
                List of Tables

                SECTION 1          SPECIFICATION                                          1-1
                                   Electrical Characteristics                             1-1
                                   Environmental                                          1-5
                                   Physical                                               1-5

                SECTION 2          OPERATING INSTRUCTIONS                                 2-1
                                   Installation                                           2-1
                                   Front-Panel Controls, Connectors, and Indicators       2-2
                                        Main Triggering Controls                          2-2
                                        Sweep Controls                                    2-4
                                        Delayed Triggering Controls                       2-4
                                        Front-Panel Inputs                                2-5
                                   Familiarization Procedure                              2-5
                                        Setup Procedure                                   2-5
                                        Sweep Functions                                   2-6
                                        Triggering Functions                              2-6
                                   General Operating Information                          2-8
                                        Main Triggering                                   2-8
                                        Main Trigger Modes                                2-8
                                        Main Trigger Coupling                             2-8
                                        Main Trigger Source                               2-9
                                        Input Impedance                                   2-9
                                        Trigger Slope                                     2-9
                                        Trigger Level                                     2-11
                                        Selecting Sweep Rates                             2-11
                                        Time Measurement                                  2-11
                                        Display Modes                                     2-11
                                        Delay Time Multiplier                             2-12
                                        Delayed Sweep Triggering                          2-12
                                        Mainframe Operating Modes                         2-13
                                   Applications                                           2-13
                                        Time Duration Measurements                        2-13
                                        Determining Frequency                             2-13
                                        Risetime Measurements                             2-14
                                        Delayed Sweep Measurements                        2-14
                                        Delayed Sweep Magnification                       2-15
                                        Triggered Delayed Sweep Magnification             2-16
                                        Displaying Complex Signals Using Delayed Sweep    2-16
                                        Pulse Jitter Measurements                         2-17

                SECTION 3               OPTIONS                                           3-1




REV . A, NOV . 197 5
7B92A Operators




                                 LIST OF ILLUSTRATIONS
             FIGURE NO .                                                                  PAGE

                  1-1      7B92A Dual Time Base .                                          iv

                  2-1      Location of Variable and Mainframe Selector multi-pin          2-1
                           connectors .

                  2-2      Location of release latch.                                     2-2

                  2-3      Front panel controls and connectors .                          2-3

                  2-4      Effect of LEVEL control and SLOPE switch on crt display .      2-10

                  2-5      Area of graticule used for most accurate time measurements .   2-11
                  2-6      Typical alternate sweep display.                               2-12

                  2-7      Measuring the time duration between points on a waveform .     2-13
              2-8          Measuring risetime .                                           2-14
              2-9          Measuring time difference using delayed sweep.                 2-15
              2-10         Using delayed sweep for magnification.                         2-16
              2-11         Displaying a complex signal using delayed sweep.               2-17

              2-12         Measuring pulse jitter .                                       2-18
                                             7B92A Operators




             LIST OF TABLES

TABLE NO .                                 PAGE

  1-1         Electrical Characteristics   1-1

  1-2         Environmental                1-5

  1-3         Physical                     1-5

  2-1         Risetime Measurements        2-14
7B92A Operators




                                                                                                                  175215




                                                    7B92A Features
The 7B92A Dual Time Base unit provides normal, delayed, intensified, and al et nate sweep operation for Tektronix 7000-
Series Oscilloscopes . Calibrated sweep rates from 0 .2 second to 0 .5 nanosecond and triggering to 500 megahertz are pro-
vided . The 7B92A is intended for use with high frequency 7000 Series Oscilloscope systems ; however, most 7B92A
functions are compatible with all 7000-Series Oscilloscopes .

Other features include lighted pushbutton switches, compatibility with indicator oscilloscopes having an alphanumeric read-
out system, and 0 to 9 .8 times continuous sweep delay . A VARIABLE control allows continuously variable sweep rates be-
tween calibrated steps . Also, when operating in the AUTO BRAIN TRIGGERING MODE, a bright base line is displayed in
the absence of a trigger signal .



                                              Fig. 1-1 . 7B92A Dual Time Base .



iv                                                                                                       REV . A, NOV. 1975
                                                                                                                      Section 1-7B92A Operators




                                                         SPECIFICATION

This instrument will meet the electrical characteristics listed under Performance Requirement in Table 1-1, following com-
plete calibration . The following electrical characteristics apply over an ambient temperature range of OOC to +500C, except
as otherwise indicated. Warmup time for given accuracy is 20 minutes.


                                                                     TABLE 1-1
                                                              Electrical Characteristics

                   Characteristic                                   Performance Requirement                                  Supplemental
                                                                                                                              Information


    MAIN TRIGGERING

Trigger Sensitivity                                 Triggering Frequency                Minimum Triggering
                                                            Range                         Signal Required

      Operating in AUTO, NORM, or                                                        INT2           EXT3
      SINGLE SWEEP MODE                                                                  (div)          (mV)

      COUPLING
         AC                                         30 Hz to 20 MHz                      0.5            100
                                                    20 MHz to 500 MHz                    1 .0           500

         AC LF REJ'                                 30 Hz to 20 MHz                      0.5            100
                                                    20 MHz to 500 MHz                    1 .0           500

         AC H F REJ                                 30 Hz to 50 H z                      0.5            100

         DC                                         Dc to 20 MHz                         0.5            100
                                                    20 MHz to 500 MHz                    1 .0           500

      Operating in HF SYNC MODE
         AC                                         100 MHz to 500 MHz                   0.5            100             Use NORM or SINGLE
         AC LF REJ                                                                                                      SWEEP MODE for signals
         DC                                                                                                             below about 30 Hz

         AC HF REJ                                  Not recommended for HF
                                                    SYNC mode



    External Trigger Input
      Level Range
         EXT                                        At least + and -3 .5 volts                                          Not applicable in HF SYN(
                                                                                                                        MAIN TRIGGERING
         EXT - 10                                   At least + and -35 volts                                            Mode

Maximum Safe Input
      1 M52 Input                                                                                                       250 V (dc + peak ac)
      5052 Input                                                                                                        1 W average (7 V rms)
'   Will not trigger on the sine waves of 8 div amplitude or less (internal), or 3 V or less (external) at 60 Hz or below.
z For Internal Triggering only, the specified -3 dB frequency of the Vertical System replaces any frequencies in the above table when the num-
  ber in the table is greater than the -3 dB frequency of the Vertical System .
s Triggering signal amplitude requirements increased by factor of 10 for EXT _ 10 operation.

REV. A, APR . 1975
Specification-71392A Operators


                                                           TABLE 1-1 (cont .)
                                                        Electrical Characteristics

                                                                                                                     Supplemental
                 Characteristic                               Performance Requirement
                                                                                                                      Information


MAIN TRIGGERING (cont.)
Input R and C
   1 MR Input                                                                                                  Approximately 1 MR
                                                                                                               paralleled by approxi-
                                                                                                               mately 20 pF
   50 SZ Input
      Resistance                                                                                               50 R within 7%
      Reflection Coefficient (Time                                                                             0.1 p-p (using 1 GHz Re-
      Domain)                                                                                                  flectometer)

Trigger Jitter
   Internal or External                        50 ps or less at 500 MHz


DELAYED TRIGGERING

Trigger Sensitivity                            Triggering Frequency              Minimum Triggering
                                                        Range                     Signal Required
                                                                                   INTO          EXT
                                                                                  (div)          (m V)

   COUPLING

      AC                                       30 Hz to 20 MHz                    0.5             100
                                               20 MHz to 500 MHz                  1 .0            500

      DC                                       Dc to 20 MHz                       0.5             100
                                               20 MHz to 500 MHz                  1 .0            500

Trigger Jitter
   Internal or External                        50 ps or less at 500 MHz

External Trigger Input
   Level Range
      EXT                                      At least +3 .5 V to -3 .5 V

Maximum Safe Input
   1 MR Input                                                                                                  250 V (dc + peak ac)
   50 S2 Input                                                                                                  1 W average (7 V rms)


Input R and C
   1 MR Input                                                                                                  Approximately 1 MR
                                                                                                               paralleled by approxi-
                                                                                                               mately 20 pF


"The specified -3 dB frequency of the Vertical System replaces any frequencies in the above table when the number in the table is greater than
 the -3 dB frequency of the Vertical System .



                                                                                                                         REV. A, APR . 1975
                                                                                         Specification-71392A Operators


                                                  TABLE 1-1 (cont .)
                                               Electrical Characteristics


                                                      Performance Requirement                            Supplemental
                  Characteristic                                                                          Information


DELAYED TRIGGERING (cont .)
Input R and C (cont .)
   50 St Input
       Resistance                                                                                   50 S2 within 7%

       Reflection Coefficient (Time                                                                 0 .1 p-p (using 1 GHz
       Domain)                                                                                      Reflectometer)


NORMAL, ALT (Delayed Sweep
Trace) and DLY'D SWEEP

Sweep Rates                           0 .2 s/div to 0 .5 ns/div in 27 calibrated steps             Selected by TIME/DIV
                                                                                                   switch . Steps in a 1-2-',
                                                                                                   sequence

Sweep Accuracy                        Measured in 7900-Series Oscilloscope

   Over Center 8 Div                    +15 