Service Manuals, User Guides, Schematic Diagrams or docs for : Tektronix CFG253 tektronix_cfg253_3_mhz_function_generator_sm

<< Back | Home

Most service manuals and schematics are PDF files, so You will need Adobre Acrobat Reader to view : Acrobat Download Some of the files are DjVu format. Readers and resources available here : DjVu Resources
For the compressed files, most common are zip and rar. Please, extract files with Your favorite compression software ( WinZip, WinRAR ... ) before viewing. If a document has multiple parts, You should download all, before extracting.
Good luck. Repair on Your own risk. Make sure You know what You are doing.




Image preview - the first page of the document
tektronix_cfg253_3_mhz_function_generator_sm


>> Download tektronix_cfg253_3_mhz_function_generator_sm documenatation <<

Text preview - extract from the document
    p                                                   Service Procedures




      Product:              CFG253               3 Mhz Function Generator

               Title:       Performance Verification & Adjustment




                        Procedure #: CP1005                 Revision: A

 Prepared By:             Roy Lindley
                          Measurement Business Service Support




REVISION LEVEL SUMMARY:


Revision #      Date        Initiator        Level Change          Description
                                             From: To:
A               5/16/97     Roy Lindley      n/a                   Initial release




CFG253                      Performance Verification & Adjustment Procedures
Page 1 of 19                       Procedure #: CP1005 Revision: A
         CFG253 PERFORMANCE VERIFICATION PROCEDURE


CONTENTS:

      Preparation                                     3

      Check DC Offset                                 3

      Check Main Output Amplitudes                    4

      Square Wave Overshoot, Rise/Fall Time           6

      Check Square Wave Duty Cycle                    7

      Sync (TTL) Output                               8

      Sine Wave Distortion                            9

      Frequency Dial Accuracy                         9




INTRODUCTION

To ensure instrument accuracy, check its performance after every 2000 hours of operation or
once each year if used infrequently.

The instrument case does not have to be removed for the Performance Check procedure. All
necessary controls and connectors are accessible from the outside.




      Test Equipment:         Requirement:                   Example:
      Test Oscilloscope       5mV-5V/Div, 50nS/Div           Tek TDS210
      Frequency Counter       > 3MHz, < 1 %                  Tek CMC251
      Distortion Analyzer     100KHz                         AA501A
      Coax Cable              50 ohm                         P/N 012-0057-01
      50 Ohm Terminator                                      P/N 011-0049-01




CFG253                    Performance Verification & Adjustment Procedures
Page 2 of 19                     Procedure #: CP1005 Revision: A
PREPARATION

Connect the instrument and test equipment to an appropriate power source and allow 20
minutes for warm up and stabilization. Set the controls as listed below during warm up.


Initial CFG253 Set-Up:

       AMPLITUDE                     Mid Range
       DC OFFSET                     Pushed In
       SYMMETRY                      Midrange Detent
       RANGE                         1K
       FUNCTION                      All Buttons Out
       VOLTS OUT                     Button Out
       FREQ/10                       Button Out
       SWEEP                         Button Out
       SWEEP RATE                    Midrange
       SWEEP WIDTH                   Midrange
       FREQ DIAL                     0.3



1.     CHECK DC Offset

       a.       Pull out the DC OFFSET knob.

       b.       Test Scope Set-Up:

                Volts/Div                 2V
                Time/Div                  0.2 mSec

       c.       Connect MAIN OUTPUT to test scope vertical input via coax cable and 50 ohm
                terminator.

       d.       Set test scope Vert Coupling to GROUND, center the trace, then set Coupling
                back to DC.

       e.       While turning the DC OFFSET knob from CCW to CW and back, check for for >
                +5 V with DC OFFSET knob CW and > -5 V with the knob CCW (+/- 2.5 Div on
                test scope).

       f.       Push the DC OFFSET knob in (off).




 CFG253                     Performance Verification & Adjustment Procedures
 Page 3 of 19                      Procedure #: CP1005 Revision: A
2.     CHECK MAIN OUTPUT AMPLITUDES


       a.       Set-Up:

                AMPLITUDE                  CW
                DC OFFSET                  Pushed In
                RANGE                      1K
                FUNCTION                   Triangle
                VOLTS OUT                  Button Out
                FREQ/10                    Button Out
                FREQ DIAL                  3.0


       b.       Test Scope Set-Up:

                Volts/Div                  2V
                Time/Div                   0.2 mSec

       c.       Connect MAIN OUTPUT to test scope vertical input via coax cable and 50 ohm
                terminator.

       d.       Check the test scope display for > 5 divisions (10V).

       e.       Rotate the AMPLITUDE knob to nearly CCW.

       f.       Set test scope to 10 mV/Div. Check that the display reduces to less than 5
                divisions (50mV) as the AMPLITUDE knob approaches the CCW stop.

       g.       Set the VOLTS OUT button in and change the test scope Volts/Div to 5mV.

       h.       Check for a display of < 1 division (5mV) as the knob approaches the CCW stop.

       i.       Set the test scope Volts/Div to 0.2 V. Rotate the AMPLITUDE knob fully CW.

       j.       Check the display for > 5 divisions (1V).

       k.       Return the VOLTS OUT button to the out position and ensure that the
                AMPLITUDE is CW.




 CFG253                      Performance Verification & Adjustment Procedures
 Page 4 of 19                       Procedure #: CP1005 Revision: A
      l.       Set the FUNCTION to Square Wave. Use the CFG253 and test scope settings in
               Table 1 to check the MAIN OUTPUT AMPLITUDE for the indicated settings :


                                                TABLE 1


           Function          Range        Volts Out     Freq.     Test Scope        Test Scope
                                           button       Dial       Volts/Div         Display
           Square Wave         1K           Out          3.0        2V/Div           > 5 Div
           Sine Wave           1K           Out          3.0        2V/Div           > 5 Div
           Sine Wave           1K           Out          0.3        2V/Div           > 5 Div
           Square Wave         1K           Out          0.3        2V/Div           > 5 Div
           Triangle            1K           Out          0.3        2V/Div           > 5 Div


      m.       Remove the 50 ohm terminator and connect the coax cable directly to the test
               scope input.

      n.       Set the test scope Time/Div to 1uSec.

      o.       Check the test scope display for each setting in Table 2:

                                                TABLE 2

                  Function        Range     Volts       Freq.     Volts/D        Display
                                            Out         Dial        iv
                  Triangle          1M      Out          3.0      5V/Div         > 4 Div
                SquareWave          1M      Out          3.0      5V/Div         > 4 Div
                 Sine Wave          1M      Out          3.0      5V/Div         > 4 Div


      p.       Press the VOLTS OUT button in. Check the test scope display for the settings in
               Table 3:

                                                TABLE 3

                   Function         Range      Volts     Freq.      Volts/Div        Display
                                               Out       Dial
                  Sine Wave          1M         In        3.0       0.5V/Div         > 4 Div
                 Square Wave         1M         In        3.0       0.5V/Div         > 4 Div
                   Triangle          1M         In        3.0       0.5V/Div         > 4 Div



CFG253                        Performance Verification & Adjustment Procedures
Page 5 of 19                         Procedure #: CP1005 Revision: A
       q.       Rotate the AMPLITUDE knob nearly CCW.

       r.       Set the test scope Volts/Div to 5mV.

       s.       Check the display for < 2 divisions (10mV) as the knob nears the CCW stop.


3.     Square Wave Rise Time and Fall Time


       a.       Test Scope Set-Up:

                Volts/Div                  5V
                Time/Div                   0.5 uSec
                Trig Slope                 +

       b.       Set-Up:

                AMPLITUDE                  CW
                DC OFFSET                  Pushed In
                RANGE                      100K
                FUNCTION                   Square Wave
                VOLTS OUT                  Button Out
                FREQ/10                    Button Out
                FREQ DIAL                  3.0


       c.       Connect MAIN OUTPUT to test scope vertical input via coax cable WITHOUT
                the 50 ohm terminator.

       d.       Adjust AMPLITUDE knob for a 4 division display on the test scope.

       e.       Set Time/Div to 50 nSec/Div. Adjust Trig Level control as necessary to display
                the rising edge of the Square Wave.

       f.       Check risetime between the 10% and 90% points for < 100 nSec (2 Div).

       g.       Set test scope Trig Slope to - (negative). Adjust Trig Level to view the Falling
                edge of Square Wave.

       h.       Check the Fall Time between the 10% and 90% points for < 100 nSec (2 Div).




 CFG253                      Performance Verification & Adjustment Procedures
 Page 6 of 19                       Procedure #: CP1005 Revision: A
4.     Check Square Wave Duty Cycles


       a.       Set-Up:

                AMPLITUDE                  Midrange
                RANGE                      1K
                FUNCTION                   Square Wave
                FREQ/10                    Button In
                FREQ DIAL                  3.0


       b.       Test Scope Set-Up:

                Volts/Div                  1V
                AC/GND/DC                  DC
                Time/Div                   0.2 mSec
                Trig Slope                 +


       c.       Connect MAIN OUTPUT to test scope vertical input via coax cable and 50 ohm
                terminator. Adjust Trig Level as necessary for a stable display.

       d.       Use test scope variable Time/Div control to set the display for 1 complete cycle
                over 10 divisions.

       e.       Check for nearly equal positive and negative half cycles (50 % duty cycle).
                Readjust the variable Time/Div as necessary to maintain 1 complete cycle over
                10 divisions.

       f.       Set FREQ/10 button out.

       g.       Check that the frequency increases by a factor of 10 as shown by a display of
                approximately 1 cycle per division on the test scope.

       h.       Set the FREQ/10 button in. Rotate the SYMMETRY knob CCW and use the
                Time/Div variable to set the first half cycle to 1 division. Rotate the SYMMETRY
                knob CW and check for the same half cycle to increase to 5 divisions or greater (a
                duty cycle change of 5:1).

       i.       Return the SYMMETRY knob to the center detent position and the test scope
                Time/Div variable to the detent position.




 CFG253                      Performance Verification & Adjustment Procedures
 Page 7 of 19                       Procedure #: CP1005 Revision: A
       j.       Repeat steps d and e to verify the 50 % duty cycles for the settings in Table 4.



                                                Table 4


                 RANGE      FREQ. DIAL       FREQ/10      TIME/DIV            RESULT
                   1K          3.0            OUT          20uSec          50 % Duty Cycle
                   1K          0.3            OUT          0.2mSec         50 % Duty Cycle
                   1K          0.3             IN          2 MSec          50 % Duty Cycle
                  100K         0.3            OUT           2 uSec         50 % Duty Cycle
                   1M          0.3             IN           2 uSec         50 % Duty Cycle



5.     SYNC (TTL) OUTPUT

       a.       Set-Up:

                AMPLITUDE                  CW
                RANGE                      1K
                FUNCTION                   Triangle
                VOLTS OUT                  Button Out
                FREQ/10                    Button Out
                FREQ DIAL                  3.0


       b.       Test Scope Set-Up:

                Volts/Div                  1V
                Time/Div                   0.2 mSec


       c.       Connect SYNC/TTL OUTPUT directly to the test scope vertical input via a coax
                cable (without the 50 ohm terminator).

       d.       Check the test scope for a display of approximately 4 volts (4 divisions).

       e.       Repeat step d with the FUNCTION set to Square Wave and Sine Wave.




 CFG253                      Performance Verification & Adjustment Procedures
 Page 8 of 19                       Procedure #: CP1005 Revision: A
6.     SINE WAVE DISTORTION

       a.       Set-Up:

                RANGE                      100K
                FUNCTION                   Sine Wave
                VOLTS OUT                  Button Out
                FREQ/10                    Button Out
                FREQ DIAL                  1.0


       b.       Connect MAIN OUTPUT to Distortion Analyzer via coax cable and 50 ohm
                terminator.

       c.       Set the Distortion Analyzer INPUT RANGE to Auto Range, and the FUNCTION
                settings to Volts, Auto Range and THD+N.

       d.       CHECK- For less than 1% distortion for the frequencies listed in Table 5:


                                    Table 5


                   RANGE      FREQ DIAL          PER CENT
                                                DISTORTION
                    100K           1.0             <1%
                     10K           1.8             <1%
                      1K           1.8             <1%
                     100           1.8             <1%
                      10           1.0             <1%




7.     FREQUENCY DIAL ACCURACY

       a.       Set-Up:

                AMPLITUDE                  CW
                RANGE                      1K
                FUNCTION                   Triangle
                VOLTS OUT                  Button In
                FREQ/10                    Button Out
                FREQ DIAL                  3.0


 CFG253                      Performance Verification & Adjustment Procedures
 Page 9 of 19                       Procedure #: CP1005 Revision: A
      b.        Connect the CFG253 MAIN OUTPUT to the input of a Frequency Counter.
                Check the frequency reading for each set-up listed in Table 6:


                                   Table 6

                 RANGE    FREQ DIAL          COUNTER READING
                   1M        3.0             2.85 MHz - 3.15 MHz
                   1M        0.3             150 KHz - 450 KHz *
                  100 K      3.0              285 KHz - 315 KHz
                   10 K      3.0              28.5KHz - 31.5KHz
                    1K       3.0              2.85KHz - 3.15KHz
                   100       3.0               285 Hz - 315 Hz
                    10       3.0               28.5 Hz - 31.5 Hz
                     1       3.0               2.85 Hz - 3.15 Hz

                *     The Frequency reading accuracy is 5% of full scale. 5% of 3 MHz is 150
                      KHz


      c.        Disconnect cable from the Counter and CFG253.




CFG253                      Performance Verification & Adjustment Procedures
Page 10 of 19                      Procedure #: CP1005 Revision: A
                 CFG253 ADJUSTMENT PROCEDURE


                                             NOTE:

                      The Adjustment procedure should be performed only by
                                  qualified service technicians.


CONTENTS:

       Preparation                                           11
       Test equipment requirements                           12
       Set U1 input voltage                                  12
       Set Q5 gate voltage                                   12
       Adjust square wave duty cycle                         13
       Set DC offset                                         14
       Square wave overshoot, rise and fall times            15
       Set output levels                                     15
       Sine wave distortion                                  16
       Frequency dial accuracy                               17
       Reassembly                                            19


PREPARATION FOR ADJUSTMENT

This procedure should be accomplished at an ambient temperature of 21 to 25 degrees C and
a relative humidity of 75% or less.

It is necessary to remove the bottom cover from the instrument to gain access to the
adjustments used in this procedure.

Turn off the POWER switch, disconnect the power cord and place the CFG253 upside down
on its top.

Remove the 2 screws in the rear feet and the 2 screws BESIDE the front feet.

Carefully lift the bottom cover off the unit, remove the handle and set these aside along with
the screws for later reassembly.

Reconnect the power cord from an appropriate AC power source and allow the instrument a
20 minute warm up period.



 CFG253                   Performance Verification & Adjustment Procedures
 Page 11 of 19                   Procedure #: CP1005 Revision: A
Test Equipment requirements

       The test equipment listed in the Table on Page 2 is a list of the equipment needed for
       this performance check. All test equipment is assumed to be operating within
       tolerance. Detailed operating instructions for test equipment are not given in this
       procedure. If operating information is needed, refer to the appropriate test equipment
       instruction manual.

Initial CFG253 Set-Up:

       AMPLITUDE                     CCW
       DC OFFSET                     Pushed In
       SYMMETRY                      Midrange Detent
       RANGE                         1K
       FUNCTION                      All Buttons Out
       VOLTS OUT                     Button Out
       FREQ/10                       Button Out
       SWEEP                         Button Out
       SWEEP RATE                    Midrange
       SWEEP WIDTH                   Midrange
       FREQ DIAL                     0.3


1.     Set U1 Input Voltage

       a.        Set digital multimeter to DC mV range

       b.        Connect multimeter test leads to pins 2 and 3 of Integrated Circuit U1.


                                     Note: Alternate Test Points

                 Locate R8 and R9 at the front left edge of the Main circuit board.
                 Pin 2 is connected to the end of R8 nearest the board edge. Pin 3 is
                 connected to the end of R9 furthest from the board edge.

       c.        Adjust R10 for approximately 0 mV.


2.     Set Q5 Gate Voltage

       a.        Connect common lead of multimeter to ground and the positive lead to the wire
                 loop test point near gate of Q5. (on the Main board under rear edge of the
                 elevated Switch board).

       b.        Adjust R33 for approximately 0 mV.


 CFG253                       Performance Verification & Adjustment Procedures
 Page 12 of 19                       Procedure #: CP1005 Revision: A
3.     Adjust Square Wave Duty Cycles

       a.        Set-Up:

                 AMPLITUDE                  Midrange
                 RANGE                      1K
                 FUNCTION                   Square Wave
                 FREQ/10                    Button In
                 FREQ DIAL                  3.0

       b.        Test Scope Set-Up:

                 Volts/Div                  1V
                 AC/GND/DC                  DC
                 Time/Div                   0.2 mSec


       c.        Connect MAIN OUTPUT to test scope vertical input via coax cable and 50 ohm
                 terminator. Adjust Trig Level as necessary for a stable display.

       d.        Use test scope variable Time/Div control to set the display for 1 complete cycle
                 over 10 divisions.

       e.        Adjust R67 for equal positive and negative half cycles (50 % duty cycle).
                 Readjust the variable Time/Div as necessary to maintain 1 complete cycle over
                 10 divisions.

       f.        Set FREQ/10 button out.

       g.        Adjust R126 for 1 cycle per division on the test scope.

       h.        Repeat steps d and e to set the 50 % duty cycles for the settings and adjustments
                 in Table 1.

                                                Table 1

            RANGE      FREQ. DIAL      FREQ/10      TIME/DIV      ADJUST         RESULT
              1K          3.0            OUT        20uSec        R127           50 % Duty Cycle
              1K          0.3            OUT        0.2mSec       R18            50 % Duty Cycle
              1K          0.3             IN        2 MSec        R16            50 % Duty Cycle
             100K         0.3            OUT        2 uSec        R132           50 % Duty Cycle
              1M          0.3             IN        2 uSec        R128           50 % Duty Cycle



 CFG253                       Performance Verification & Adjustment Procedures
 Page 13 of 19                       Procedure #: CP1005 Revision: A
4.     Set DC Offset


       a.        Set-Up:

                 DC OFFSET                  Pulled Out
                 RANGE                      1K
                 FUNCTION                   All Buttons Out
                 VOLTS OUT                  Button Out
                 FREQ/10                    Button Out


       b.        Test Scope Set-Up:

                 Volts/Div                  2V
                 Time/Div                   0.2 mSec
                 Var Time/Div               Cal


       c.        Connect MAIN OUTPUT to test scope vertical input via coax cable and 50 ohm
                 terminator.

       d.        Set test scope Vert Coupling to GROUND, center the trace, then set Coupling
                 back to DC.

       e.        While turning the DC OFFSET knob from CCW to CW and back, adjust R117 for
                 equal voltage swings positive and negative on the test scope.

       f.        Adjust R129 for 5.1 V with DC OFFSET knob CW and -5.1 V with the knob CCW
                 (2.55 Div on test scope). Repeat step e, if necessary.

       g.        Push the DC OFFSET knob in (off).

       h.        Set the test scope to 10 mV/Div.

       i.        Set test scope Vert Coupling to GROUND, center the trace, then set Coupling
                 back to DC.

       j.        Slowly adjust R82 to recenter the trace, set to within 1 division of center (+/- 10
                 mV).




 CFG253                       Performance Verification & Adjustment Procedures
 Page 14 of 19                       Procedure #: CP1005 Revision: A
5.     Square Wave Overshoot, Rise Time and Fall Time

       a.        Test Scope Set-Up:

                 Volts/Div                  5V
                 Time/Div                   0.5 uSec
                 Trig Slope                 +

       b.        Set-Up:

                 AMPLITUDE                  CW
                 DC OFFSET                  Pushed In
                 RANGE                      100K
                 FUNCTION                   Square Wave
                 VOLTS OUT                  Button Out
                 FREQ/10                    Button Out
                 FREQ DIAL                  3.0

       c.        Connect MAIN OUTPUT to test scope vertical input via coax cable WITHOUT
                 the 50 ohm terminator.

       d.        Adjust AMPLITUDE knob for a 4 division display on the test scope.

       e.        Adjust C31 for minimum overshoot (will not be completely flat).

       f.        Set Time/Div to 50 nSec/Div. Adjust Trig Level control as necessary to display
                 the rising edge of the Square Wave.

       g.        Check risetime between the 10% and 90% points for < 100 nSec (2 Div).

       h.        Set test scope Trig Slope to - (negative). Adjust Trig Level to view the Falling
                 edge of Square Wave.

       i.        Check the Fall Time between the 10% and 90% points for < 100 nSec (2 Div).


6.     Set OUTPUT Levels

       a.        Set-Up:

                 AMPLITUDE                  CW
                 DC OFFSET                  Pushed In
                 RANGE                      1K
                 FUNCTION                   Triangle
                 VOLTS OUT                  Button Out
                 FREQ/10                    Button Out
                 FREQ DIAL                  3.0


 CFG253                       Performance Verification & Adjustment Procedures
 Page 15 of 19                       Procedure #: CP1005 Revision: A
       b.        Test Scope Set-Up:

                 Volts/Div                  2V
                 Time/Div                   0.2 mSec
                 Trig Slope                 +

       c.        Connect MAIN OUTPUT to test scope vertical input via coax cable and 50 ohm
                 terminator.

       d.        Adjust R130 for approximately 10.5 V p-p output display on test scope (5.25
                 Div).

       e.        Set RANGE to 1M and FREQ DIAL to 0.3.

       f.        Note the test scope display amplitude.

       g.        Observe the display amplitude for > 10 V while turning the FREQ DIAL from 0.3
                 to 3.0.

       h.        Set the FREQ DIAL to 3.0. Adjust C55 for the same amplitude as observed in
                 step f.

       i.        Repeat steps a thru h for the Sine Wave function. In step d, adjust R74 for 10.8
                 V. In step h, use C26.

       j.        Set FUNCTION to Square Wave, RANGE to 1K and FREQ DIAL to 3.0.

       k.        Adjust R56 for approximately 10.8 V on the test scope display (5.4 Div).


7.     Sine Wave Distortion

       a.        Set-Up:

                 RANGE                      100K
                 FUNCTION                   Sine Wave
                 VOLTS OUT                  Button Out
                 FREQ/10                    Button Out
                 FREQ DIAL                  1.0

       b.        Connect the MAIN OUTPUT to the Distortion Analyzer via a coax cable and a 50
                 ohm terminator.




 CFG253                       Performance Verification & Adjustment Procedures
 Page 16 of 19                       Procedure #: CP1005 Revision: A
       c.        Set the Distortion Analyzer INPUT RANGE to Auto Range and the FUNCTION
                 settings to Volts, Auto Range and THD+N.

       d.        Adjust R43 and R46 for a minimum distortion reading on the Distortion
                 Analyzer. Repeat the two adjustments as necessary to obtain the optimum
                 results.

       e.        Disconnect the cable from the Distortion Analyzer.

                                      *** Alternate Procedure ***

                              ( If Distortion Analyzer is not available )

       f.        Test Scope Set-Up:

                 Volts/Div                 2V
                 Time/Div                  1 uSec

       g.        Connect MAIN OUTPUT to test scope vertical input via coax cable and 50 ohm
                 terminator.

       h.        Adjust R46 for minimum distortion at top of sinewave and R43 for minimum
                 distortion at the bottom.

7.     FREQUENCY DIAL ACCURACY

       a.        Set-Up:

                 AMPLITUDE                 CW
                 RANGE                     1K
                 FUNCTION                  Triangle
                 VOLTS OUT                 Button In
                 FREQ/10                   Button Out
                 FREQ DIAL                 3.0

       b.        Connect the MAIN OUTPUT to the input of a Frequency Counter.

                                                  NOTE:

                             If a Frequency Counter is not a available, see
                             alternate procedure on next page.

       c.        Adjust R6 for a reading of 3.0 KHz on the Frequency Counter.




 CFG253                      Performance Verification & Adjustment Procedures
 Page 17 of 19                      Procedure #: CP1005 Revision: A
      d.        Set the RANGE to 1M and adjust C8 for a reading of 3.0 MHz on the Frequency
                Counter.

      e.        Check the Frequency Counter readout while changing the CFG253 FUNCTION
                between Sine Wave and Square Wave. Adjust R76 for approximately 3.0 MHz,
                setting for the best compromise between Sine Wave and Square Wave.



                                     *** Alternate Procedure ***

                             ( If a Frequency Counter is not available )


      f.        Set-Up:

                AMPLITUDE                         CW
                RANGE                      1K
                FUNCTION                   Triangle
                VOLTS OUT                  Button Out
                FREQ/10                    Button Out
                FREQ DIAL                  3.0

      g.        Test Scope Set-Up:

                Volts/Div                  0.5 V
                Time/Div                   0.2 mSec


      h.        Connect SYNC/TTL OUTPUT to test scope vertical input via coax cable and 50
                ohm terminator.

      i.        Adjust R6 for a display of 6 cycles in 10 Divisions on the test scope. (3KHz)

      j.        Set RANGE to 1M and the test scope Time/Div to 0.2 uSec.

      k.        Adjust C8 for a display of 6 cycles in 10 Divisions on the test scope. (3MHz)

      l.        Check display while changing the FUNCTION between Sine Wave and Square
                Wave. Adjust R76 for 6 cycles in 10 Divisions, setting for the best compromise
                between Sine Wave and Square Wave frequencies.




CFG253                       Performance Verification & Adjustment Procedures
Page 18 of 19                       Procedure #: CP1005 Revision: A
REASSEMBLY


      1.        Disconnect any cables connected to the CFG253, turn off the POWER switch and
                remove the power cord.

      2.        With the unit setting upside down on its top, place the handle upside down in
                its opening in the case top and carefully slide the case bottom onto the unit. Be
                sure that the front and back grooves line up and slip over the front and rear
                panels.

      3.        Reinstall the two rear feet and screws plus the two front screws.




CFG253                       Performance Verification & Adjustment Procedures
Page 19 of 19                       Procedure #: CP1005 Revision: A