Setting PDH Receive Parameters

            This section describes how to manually set the receive rate, receive
            level, framing, and test pattern for PDH signals.
            Pressing AUTOSCAN sets the receive parameters automatically
            based on the received signal.


Steps for Setting Parameters
            The sequence of steps for setting receive parameters varies with
            signal to be received. Figure 3 60 shows the sequence of steps
            required to set the receive parameters for PDH signals (for example,
            2 Mb/s).


 Set         Set Receive      Set Payload and          Set Test
 Rate           Level         Payload Framing          Pattern

Figure 3 60:Sequence for Setting PDH Signal Parameters (non demuxed)


  Set               Set      Set Payload        Set Test            Set
  Rate             Level     and Payload        Pattern            Active
                               Framing                            Channel

           Set
         Payload
         Drop to
           ON


Figure 3 61:Sequence for Setting PDH Signal Parameters When demultiplexing a
PDH Signal (demuxed)


            CTS850 SDH/PDH Test Set




CTS850 SDH/PDH Test Set User Manual                                          3 147
Setting PDH Receive Parameters




Selecting 64k RX Settings
         If the operator selects a SDH rate with PDH mapping or a PDH
         Transmit Rate and a 64k payload on the Receive Setting screen, the
         64k Rx SETTINGS menu is enabled.
         This menu has all of the setup items required to configure a 64k or
         N x 64k signal, along with duplicates of the framing selections and
         test pattern choices.




         Figure 3 62:64k Rx SETTINGS from RECEIVE SETTINGS menu



         Table 3 22:64k Rx SETTINGS Choices

          64k RX Settings   Choices
          Framing           Selects the framing for the underlying 2 Mb/s signal.
                            Choices are 2Mb/s PCM30, PCM31, PCM30CRC, and
                            PCM31CRC.
          Configuration     Selects the 64k configuration. The menu choices are
                            1x64k, Nx64k Contiguous.
          Number of Time-   If the configuration is N x 64 k, this selects the number of
          slots             contiguous channels (N) that make up the signal. This
                            choice will not display for a 64k configuration.



3 148                                  CTS850 SDH/PDH Test Set User Manual
                                                   Setting PDH Receive Parameters




        Table 3 22:64k Rx SETTINGS Choices (Cont.)

         64k RX Settings     Choices
         Starting Timeslot   This selects the starting (or only) timeslot.
         Test Pattern        This selection is a duplicate of the Test Pattern selection
                             choice from the RECEIVE SETTING menu.



Setting the Receive Rate
        To set the receive rate:


         Press Menu          Select Menu          Highlight
         Button              Page                 Parameter            Select Choice
         RECEIVE             RECEIVE           Receive Rate            as appropriate
                             SETTINGS
                             (see Figure 3 63)


        H Select 2 Mb/s, 8 Mb/s, 34 Mb/s, or 140 Mb/s to receive a PDH
          signal.
        H If your CTS 850 test set supports the 45 Mb/s option, there is also
          a 45 Mb/s signal available for selection.




CTS850 SDH/PDH Test Set User Manual                                                 3 149
Setting PDH Receive Parameters




                                         Available PDH
                                          receive rates




         Figure 3 63:PDH Signal Receive Rates


         Independent Receive and Transmit Settings
         Generally, you can set the receive and transmit settings independent-
         ly. For example, you can receive an electrical signal at the 34 Mb/s
         rate while simultaneously transmitting an optical signal at the STM-1
         rate.

         Coupling Receive and Transmit Settings
         If your application requires that the receive settings and transmit
         settings be identical, you can save time by coupling them together.
         After they are coupled, any change you make to a parameter on the
         RECEIVE SETTINGS page will also be made to the corresponding
         setting in the TRANSMIT SETTINGS page of the RECEIVE menu.
         The inverse is also true.




3 150                                CTS850 SDH/PDH Test Set User Manual
                                              Setting PDH Receive Parameters




        To couple the receive and transmit settings together from the
        RECEIVE SETTINGS page:


         Press Menu        Select Menu       Highlight
         Button            Page              Parameter         Select Choice
         RECEIVE           RECEIVE           Tx/Rx Setup       Coupled
                           SETTINGS



        NOTE. When settings are coupled from the RECEIVE SETTINGS
        page, the transmit parameters are changed to match the receive
        parameters. Conversely, when settings are coupled from the
        TRANSMIT SETTINGS page, the receive parameters are changed to
        match the transmit parameters.


        To change receive and transmit settings so that they are no longer
        coupled:


         Press Menu        Select Menu       Highlight
         Button            Page              Parameter         Select Choice
         RECEIVE           RECEIVE           Tx/Rx Setup       Independent
                           SETTINGS


        Notice that the signal status icons, in the upper-right corner of the
        display, changed to indicate that the settings are no longer coupled.




CTS850 SDH/PDH Test Set User Manual                                          3 151
Setting PDH Receive Parameters




Setting the Receive Level
         For PDH Receive Paremeters, specify the receive level for electrical
         signals:


          Press Menu       Select Menu      Highlight
          Button           Page             Parameter         Select Choice
          RECEIVE          RECEIVE          Receive Level     Normal
                           SETTINGS
                                                              Monitor
                                                               20db
                                                              Monitor
                                                               30db



Setting Payload and Payload Framing
         When receiving a PDH signal you can specify payload and payload
         framing of the signal.
         To specify the framing of a received PDH signal:


          Press Menu       Select Menu      Highlight
          Button           Page             Parameter         Select Choice
          RECEIVE          RECEIVE          Payload and       as appropriate
                           SETTINGS         Payload Framing



         NOTE. The choices available for Framing depend on the selected
         Receive Rate.

            H Select 2 Mb/s Unframed to receive an unframed 2 Mb/s
              signal.
            H Select 2 Mb/s PCM30 CAS to receive a framed, 30 channel
              2 Mb/s signal with Channel Associated Signalling in Timeslot
              16.



3 152                                 CTS850 SDH/PDH Test Set User Manual
                                               Setting PDH Receive Parameters




           H Select 2 Mb/s PCM31 to receive a framed, 31 channel
             2 Mb/s signal.
           H Select 2 Mb/s PCM30 CRC/CAS to receive a framed, 30
             channel 2 Mb/s signal with Channel Associated Signalling in
             Timeslot 16 with CRC4 multiframe.
           H Select 2 Mb/s PCM31 CRC to receive a framed, 31 channel
             2 Mb/s signal with CRC4 multiframe.
           H Select 8 Mb/s Unframed to receive a unframed 34 Mb/s
             signal.
           H Select 8 Mb/s Framed to receive a framed 34 Mb/s signal.
           H Select 34 Mb/s Unframed to receive an unframed 34 Mb/s
             signal.
           H Select 34 Mb/s Framed to receive a framed 34 Mb/s signal.
           H Select 140 Mb/s Unframed to receive an unframed 140 Mb/s
             signal.
           H Select 140 Mb/s Framed to receive a framed 140 Mb/s
             signal.
           H Select 64k PCM30 CAS/CRC, 64k PCM31 CRC, 64k PCM30
             CAS, or 64k PCM31.


Specifying the Test Pattern
        To specify the test pattern of the received signal:


         Press Menu        Select Menu        Highlight
         Button            Page               Parameter       Select Choice
         RECEIVE           RECEIVE            Test Pattern    as appropriate
                           SETTINGS



        NOTE. The choices available for Test Pattern depend on the selected
        Receive Rate.




CTS850 SDH/PDH Test Set User Manual                                       3 153
Setting PDH Receive Parameters




            H Select 1 in 8 to set the test pattern to 1000 0000.
            H Select User Word 8 bit, User Word 16 bit, or User Word
              24 bit to set a test pattern different from the preset choices. If
              you choose User Word, the test pattern description changes to
              User Defined Byte.
            H Select Unknown when you do not know what test pattern is
              being transmitted or when the test pattern is not stable.
         If you select User Word for the test pattern, set the value of the User
         Word as follows:
         1. Select the line containing the byte to set the value of the User
            Defined Byte.
         2. Define the contents of the User Defined Byte as follows:


          Press Menu        Select Menu       Highlight
          Button            Page              Parameter          Select Choice
                                              select displayed   Set to 00000000
                                              byte
                                                                 Set to 11111111
                                                                 Default 10101010
                                                                 EDIT BYTE


            H Select Set to 00000000 to set the test pattern to all zeros.
            H Select Set to 11111111 to set the test pattern to all ones.
            H Select Default 10101010 to set the test pattern to alternating
              ones and zeros
         3. Select EDIT BYTE to specify a value different from the preset
            choices.
         4. Select DONE when you are finished editing the byte.




3 154                                  CTS850 SDH/PDH Test Set User Manual
                                             Setting PDH Receive Parameters




Specifying the Payload Drop
        If the Receive rate is any PDH or SDH rate, SDH is mapped for
        PDH, and the PDH payload is less than the line rate, then a selection
        appears at the bottom of Receive, Receive Settings menu. This
        selection permits the operator to drop a certain PDH payload. 8 Mb/s
        and 64k rates can not be dropped.




CTS850 SDH/PDH Test Set User Manual                                     3 155
Setting PDH Receive Parameters




Selecting RX CAS & Voice
         RX CAS runs in scan mode, where it updates all values as frequently
         as possible, or single channel mode, which permits the operator to
         select a channel and have it dropped to the speaker. These selections
         are mutually exclusive because the same CAS channel selector is
         used for picking the timeslot for reading CAS bits and dropping to
         the speaker. This screen is only accessible when the receive payload
         is 64k. If CAS is disabled, it only permits timeslot selection and
         speaker control.
         CAS is only available if the 2 Mb/s framing is PCM30 or PCM30
         CRC.




         Figure 3 64:RX CAS & Voice from Receive Setting Menu




3 156                                CTS850 SDH/PDH Test Set User Manual
                                                   Setting PDH Receive Parameters




        Table 3 23:RX CAS & Voice Choices

         Rx CAS & Voice      Choices
         CAS Display Mode The operator can select SINGLE mode, which selects a
                          single timeslot and enables the speaker drop.
         Selected Timeslot   In Single display mode, this permits selection of the
                             timeslot of interest. This selection is not displayed in scan
                             mode.
         Speaker             In Single Display mode, the operator may drop the
                             selected timeslot to the internal speaker. This field permits
                             selection of OFF, LOW, MEDIUM, and LOUD volumes.
                             Once enabled, the speaker drop will remain on until
                             disabled from this screen, or the payload is changed for
                             64k.



Setting Jitter Receive Parameters
        You can set the CTS850 to measure jitter or wander in PDH signals.
        Refer to Setting Jitter Receive Parameters in the separate section of
        this chapter on Setting Jitter/Wander Parameters for information