Text preview - extract from the document
Reference




TDS 420A, TDS 430A, TDS 460A & TDS 510A
Digitizing Oscilloscopes
070-9758-00
To Display a Waveform:                                                                                                 To Save a Hardcopy to the File System:




                                                                                                                                                                                            Press Format in the main menu, and select a
                                                                                                                        1   Press SHIFT, and then press HARDCOPY.                      2    hardcopy format from the side menu.


                                                Device Under
                                                    Test




                                                                                                                                                                                    Disk Drive




     Attach a probe to CH 1                         Press              Press          Adjust VERTICAL and HORIZONTAL
1    and hook it up to your signal.             2   CH 1 button.   3   AUTOSET.   4   POSITION and SCALE as desired.



                                                                                                                                                                                            Press HARDCOPY anytime to save a copy
                                                                                                                            Press Port in the main menu, press File in the                  of the current screen to a unique file in the
                                                                                                                        3   side menu, and then press CLEAR MENU.                      4    oscilloscope file system.



                                                                                                                        To Perform Other File System Operations:

                                                                                                                        H Press SAVE/RECALL WAVEFORM, and use the menu buttons to save a waveform to a file or
                                                                                                                          recall it from a file.

                                                                                                                        H Press SAVE/RECALL SETUP, and use the menu buttons to save a setup to a file or recall it from
                                                                                                                          a file.

                                                                                                                        H Press File Utilities in the Save/Recall Waveform, Save/Recall Setup, or Hardcopy menus to access
                                                                                                                          utilities that create directories, copy files, and do other operations in the oscilloscope file system.
Copyright E Tektronix, Inc. Printed in U.S.A.
To Zoom or Zoom Preview a Waveform:                                                                              To Set Up Using a Menu:


                                                                                                                                                                                            Use SHIFT
                                                                                                                                                                                            Button for
                                                                                                                                                                                            Alternate (Blue)
                                                                                                                                                                                            Menus




                                                                                                                  1   Press any of the front panel menu buttons.

  1    Press ZOOM.



       TDS 400A only: press Mode in the main
       menu. Then press Preview in the side menu
  2    to turn on Dual Window Zoom.

                               Upper graticule zooms the boxed area
                                           on the selected waveform.

                                                                                                                  2   Select an item from the main (bottom) menu.

                       Lower graticule displays the selected waveform
                             unzoomed with the zoomed area in box.                                                                                                        Readout Indicates Value That
                                                                                                                                                                          You Can Adjust With the
                                                                                                                                                                          General Purpose Knob

       TDS 400A only: use the Selected Graticule
  3    menu to select the upper or lower waveform.
                                                                                                                                                                          Adjustable Menu Item Value
                                                                             TDS 400A
       Use the vertical and horizontal knobs to adjust
  4    the waveform.
                                                                                                                  3   Select any displayed item from the side menu.


 To Perform Other Zoom Operations:

 H Turn the Vertical and Horizontal SCALE and POSITION knobs to adjust the scale and position factors of                                                                    General Purpose Knob
   the acquisition or the zoomed waveforms.

 H Press Lock (TDS 400A) or Horizontal Lock (TDS 510A) to choose which waveform group to zoom horizontally.                                                                 Keypad (TDS 510A)

 H TDS 400A only: press Selected Graticule, and use the menu buttons to direct the scale and position knobs to
   the upper (zoomed waveforms) or lower (acquisition waveforms) graticule.
                                                                                                                      Adjust menu item values using the general purpose
 H Press Reset Zoom Factors (TDS 510A) or Reset and use the menu buttons (TDS 400A) to reset zoom Factors.        4   knob or by entering numbers on the keypad.
                                                                                                                                                                            End Your Entry by
                                                                                                                                                                            Pressing ENTER ( )
How the Acquisition Modes Work:                                                                                          To Take Measurements Automatically:
 Incoming        Samples Acquired            Acquisition Mode           Displayed              Waveform
   Signal       for Each Waveform               Processes               Data Point           Drawn on CRT
                 Data Point Interval             Samples




                                                                                                                                                                                             Press Select Measrmnt or Snapshot
                                                                                                                          1   Press the MEASURE button.                                 2    in main menu.
                                                                                     Use for fastest acquisition rate.
                                                    Sample                           Sample is the default mode.
                                                                                                                                                           Automated Measurement Selections
                                        Uses first sample in interval
                                                                                                                                                                                                       Select
                                                                                                                                                                                                    Measurement


                                                                                     Use to reveal aliasing and for
                                                                                     glitch detection.                                                          Period     Rise Time     Delay         High        Pk