Text preview - extract from the document
Error
      Diagnosis Contents           Description of error           Automatic FL Display            Remarks
Code
 H01 Tray loading error  The tray opening and closing is                                 Press [ STOP] on
                         abnormal. CLOSE and OPEN of the                                 main unit for next error.
                         tray cannot be carried out properly.                            (OPEN time: OPEN
                         Loading motor error, DV5 LSI IC                                 CLOSE       OPEN
                         (IC8001) error.                                                 H01 at CLOSE: CLOSE
                                                                                            OPEN        CLOSE
                                                                                         H01)

H02 Spindle servo error   The spindle servo/motor is abnormal.                           Press [ STOP] on
                          The FG pulse is abnormal. CLV servo                            main unit for next error.
                          error.

H03 Traverse servo error The traverse is abnormal. (Traverse                             Press [ STOP] on
                         servo, DV5 LSI IC (IC8001), TRV                                 main unit for next error.
                         motor error.)

H04 Tracking servo error Tracking coil NG (OPU unit                                      Press [ STOP] on
                         abnormal), DV5 LSI IC (IC8001)                                  main unit for next error.
                         error.
H05 Seek time out error It is not possible to access the disc.                           Press [ STOP] on
                         TOC cannot read. Abnormal disc etc.                             main unit for next error.
                         Pickup abnormal or disk is dirty.
                         (TRV motor error, DV5 LSI IC
                         (IC8001) error.)
H07 Driver IC thermal    The spindle motor is abnormal. (short                           Press [ STOP] on
    shut down            between brushes)                                                main unit for next error.


H15 Disc tray open        The disc tray cannot be opened & it                            Press [ STOP] on
    detection switch      closes spontaneously.                                          main unit for next error.
    failure

H16 Disc tray close       The disc tray cannot be closed & it                            Press [ STOP] on
    detection switch      opens spontaneously.                                           main unit for next error.
    failure

U11 Focus servo error     Focus coil, FE signal error. Disc may                          Press [ STOP] on
                          be dirty.                                                      main unit for next error.
                                                                                         (Unfinalized DVD-R
U15 Unfinalized DVD-R                                                                    is likely to beocme U11.)


F500 DSC error            DV5 LSI IC (IC8001) stops in the                               Press [ STOP] on
                          occurance of servo error (startup,                             main unit for next error.
                          focus error, etc)

F506 Invalid media        Disc is flipped over, TOC unreadable,                          Press [ STOP] on
                          incompatible disc.                                             main unit for next error.

F620 OPU unit             Laser protection at high temperature.                          Press [ STOP] on
     abnormality                                                                         main unit for next error.
     temperature

F621 OPU unit             Laser protection at circuit failure.                           Press [ STOP] on
     circuitry                                                                           main unit for next error.
     temperature