Text preview - extract from the document
                           Item                                                                                              Key Operation
                                                                               FL Display
  Mode Name                       Description                                                                                 Front Key
Service mode       To enter into service mode.                (Display 1)                                           In STOP (no disc) mode,
  entering                                                                                                          select DVD/CD and press
                                                                                                                    [STOP] button on the main
                                                                                                                    unit, followed by [ 10] button
                                                                                                                    and [0] button on the remote
                                                              (Display 2)                                           control unit.




  Error code       Error code check                                                                                 In SERVICE mode, press [1]
     check         The latest error code stored in the                                                              button on the remote control
                   EEPROM IC is displayed.                                                                          unit. Error code will be shown
                                                                                                                    on the FL Display.
                                                                                                                    To clear the error code,
                                                                             Error code           Error code no.    press [0] for 5 seconds
                                                                             record                                 or more.
                                                            By pressing the up/down key on the remote
                                                            control. You can view the next or previous
                   Note: Refer to "Section 10.3 DVD Self    error codes present.
                   Diagnostic Function-Error Code" for      When there is no error present, the FL
                   more detailed information on the error   display shows as below:
                   codes.
                                                                                                                    To exit, press [POWER]
                                                                                                                    button on main unit or
                                                                                                                    remote control.


Micro-processor    Micro-processor firmware version           (Display 1)                                           In SERVICE mode, press [2]
firmware version   display & EEPROM checksum display.                                                               button on the remote control
    display &      EEPROM checksum is only available                                                                unit.
    EEPROM         due to existence of EEPROM IC.
    checksum
     display.      FL Display sequence:
                   Display 1 2 3 4 5             6   7.                                      Main
                                                                                             micro-processor
                                                                                             firmware version no.
                                                              (Display 2)
                                                                                                                    Press [FL Display] button on
                                                                                                                    remote control unit for next
                                                                                                                    page. (FL Display)

                                                                        Sub micro-processor IC (Digital P.C.B.)
                                                                        firmware version no. for YYY. ZZ is for
                                                                        the checksum no. if EEPROM IC
                                                                        is present.
                                                              (Display 3)




                                                                            Kernel firmware version
                                                              (Display 4)




                                                                            Miniboot version no.
                                                              (Display 5)




                                                                            Fs version no.
                                                              (Display 6)




                                                                            DSP MICRO-PROCESSOR IC
                                                                            FIRMWARE VERSION
                                                              (Display 7)
                                                                                                                    To exit, press [POWER]
                                                                                                                    button on main unit or
                                                                                                                    remote control.


                                                                            Misty key no.