Text preview - extract from the document
                           Item                                                                                     Key Operation
                                                                             FL Display
 Mode Name                        Description                                                                         Front Key
CD laser drive     CD laser drive current measurement.        (Display 1)                                     In STOP (no disc) mode,
   current         CD laser drive current is measured                                                         press [STOP] button on
measurement        and the result is displayed together                                                       the main unit, and [3]
                   with the initial value stored in the                                                       button on the remote
                   EEPROM IC.                                                                                 control unit.
                   After the measurement, CD laser                                                            To exit, press [POWER]
                   emission is kept on. It is turned off                      CD laser current                button.
                   when POWER key is switched off.                            measurement mode

                   FL Display sequence:                    The value denotes the current in decimal
                   Display 1 2.                            notation.
                                                              (Display 2)
                                                                                                              Press [FL Display] on
                                                                                                              remote control unit for next
                                                                                                              page. (FL Display)


                                                                               CD              CD laser
                                                                               laser initial   value
                                                                               value
                                                           The above example shows the initial current
                                                           is 0XXmA and the measured value is 0YYmA.


 DVD Module        DVD Module P.C.B. firmware version                                                         In STOP (no disc)
P.C.B. firmware    is displayed on the FL Display.                                                            mode, press [STOP]
version display    The firmware version can be updated                                                        button on the main unit,
                   using recovery disc.                                                                       and [8] button on the
                                                                                                              remote control unit.
                                                                                                 System       Cancelled automatically
                                                                                                 controller   5 seconds later.
                                                                                                 version
                                                                                         Destination
                   Note: It is necessary to check for                               System controller
                   firmware version before carrying out                             generation
                   the version up using the disc.                           Region No.: 0-8

                                                              (Display 1)
Communication Displays frequency of communication                                                             In STOP (no disc)
 error display errors between system control IC and                                                           mode, press [STOP]
               mechanism control IC in the DVD                                                                button on the main unit,
               Module P.C.B.                                                                                  and [MENU] button on the
                                                                                                              remote control unit.
                  FL Display sequence:                                                                        Cancelled automatically
                  Display 1 2.                                                            No. of              5 seconds later.
                                                                                          communication
                                                                                          error
                                                              (Display 2)
                                                                                                              Press [FL Display] on
                                                                                                              remote control unit for next
                                                                                                              page (FL Display).


                                                                                          No. of
                                                                                          communication



◦ Jabse Service Manual Search 2024 ◦ Jabse PravopisonTap.bg ◦ Other service manual resources online : FixyaeServiceinfo