Service Manuals, User Guides, Schematic Diagrams or docs for : panasonic Cam WEMV180 m1mv180e

<< Back | Home

Most service manuals and schematics are PDF files, so You will need Adobre Acrobat Reader to view : Acrobat Download Some of the files are DjVu format. Readers and resources available here : DjVu Resources
For the compressed files, most common are zip and rar. Please, extract files with Your favorite compression software ( WinZip, WinRAR ... ) before viewing. If a document has multiple parts, You should download all, before extracting.
Good luck. Repair on Your own risk. Make sure You know what You are doing.




Image preview - the first page of the document
m1mv180e


>> Download m1mv180e documenatation <<

Text preview - extract from the document
                                                                                          ORDER NO. AVS9506039C8




                                                                                             Video Imager

                                                                        WE-MV180




SPECIFICATIONS
   CAMERA UNIT
Pick-up Device:                  752 (H) x 582 (V) pixels, 1/3" Interline Transfer CCD
Scanning System:                 2:1 Interlace
Scanning:                        625 lines/50 fields/25 frames
  Horizontal:                    15.625 kHz
  Vertical:                      50 Hz
Video Output:                    1.0 V[p-p] PAL composite/75
S-Video Output:                  Y: 1.0 V[p-p]/75
                                 C: 0.3 V[p-p] (Burst Level)/75
Horizontal Resolution:           450 lines (at center)
Signal-to-Noise Ratio:           48 dB
White Balance:                   Automatic
Shutter Speed:                   1/120 Flickerless

   Lens Unit
Focal Length:                    5.4 - 64.8 mm (12X)
Maximum Relative Aperture:       F1.8 - F2.7
Zoom:                            Electronic power
Focus:                           Auto Focus

   Liquid Crystal Display Unit
Size:                            2.9 inch
Brightness:                      Manually adjustable
Resolution:                      480 (H) x 130 (V) pixels

                                                            C 1997 Matsushita Communication Industrial Co., Ltd.
                                                            All rights reserved. Unauthorized copying and
                                                            distribution is a violation of law.
                                                                                  !    WARNING
             This service information is designed for experienced repair technicians only and is not designed for use by the
             general public.
             It does not contain warnings or cautions to advise non-technical individuals of potential dangers in attempting to
             service a product.
             Products powered by electricity should be serviced or repaired only by experienced professional technicians. Any
             attempt to service or repair the product or products dealt with in this service information by anyone else could
             result in serious injury or death.




                                                                                              This symbol warns the user that uninsulated voltage within
                                                       CAUTION                                the unit may have sufficient magnitude to cause electric
                                                   RISK OF ELECTRIC SHOCK                     shock. Therefore, it is dangerous to make any kind of contact
                                                         DO NOT OPEN
                                                                                              with any inside part of this unit.

                                      CAUTION:
                                      TO REDUCE THE RISK OF ELECTRIC SHOCK,
                                      DO NOT REMOVE COVER (OR BACK). NO USER                  This symbol alerts the user that important literature concerning
                                      SERVICEABLE PARTS INSIDE.                               the operation and maintenance of this has been included.
                                      REFER SERVICING TO QUALIFIED SERVICE                    Therefore, it should be read carefully in order to avoid
                                      PERSONNEL.                                              any problems.



                                                                            IMPORTANT SAFETY NOTICE

                                        There are special components used in this equipment which are important for safety. These parts are indicated
                                        by the " ! " mark on the schematic diagram and the replacement parts list. It is essential that these critical
                                        parts should be replaced with manufacturer's specified parts to prevent shock, fire, or other hazards.
                                        Do not modify the original design without permission of manufacture.




    Main Unit
Video Input:                                                           1.0 V[p-p] composite/75, RCA standard jack (X2)
S-Video Input:                                                         Y: 1.0 V[p-p]/75,
                                                                       C: 0.3 V[p-p] (Burst Level)/75, Mini DIN 4-pin connector (X2)
                                                                       (Direct out via Input Selector)
Audio Input:                                                           RCA standard jack (X2)
Microphone Input:                                                      -65 dB/600, phone jack, unbalanced
Video Output:                                                          1.0 V[p-p] composite/75, RCA standard jack (X1)
S-Video Output:                                                        Y: 1.0 V[p-p]/75,
                                                                       C: 0.3 V[p-p] (Burst Level)/75, Mini DIN 4-pin connector (X1)
Audio Output:                                                          -20 dBV (1V = 0 dBV), RCA standard jack
Fluorescent lamp:                                                      6W, 12V
Ambient operating Temperature:                                         +5