Service Manuals, User Guides, Schematic Diagrams or docs for : . Car Manuals Nissan 300ZX 1984-1985,1988,1990,1994-1996 Approved 1988 Heater & AC

<< Back | Home

Most service manuals and schematics are PDF files, so You will need Adobre Acrobat Reader to view : Acrobat Download Some of the files are DjVu format. Readers and resources available here : DjVu Resources
For the compressed files, most common are zip and rar. Please, extract files with Your favorite compression software ( WinZip, WinRAR ... ) before viewing. If a document has multiple parts, You should download all, before extracting.
Good luck. Repair on Your own risk. Make sure You know what You are doing.




Image preview - the first page of the document
Heater & AC


>> Download Heater & AC documenatation <<

Text preview - extract from the document
I                                                                                                   AIR CONDITIONER

                                                                                       SECTION                   HA
CONTENTS
GENERAL DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .                 HA-    2
AIR FLOW AND COMPONENT LAYOUT (Manual) ...........................                                                                    HA-    3
LOCATION OF VACUUM COMPONENTS (Manual) ...........................                                                                    HA-    5
CONTROL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   HA-    6

HEATER ELECTRICAL CIRCUIT                               ..........................................                                    HA-   7

DESCRIPTION . Conditioner (Manual) ....................................
              Air                                                                                                                     HA-    9
DISCHARGING. EVACUATING. CHARGING AND CHECKING . . . . . . . . . . . . . . . . .                                                      HA-   10
A/C PERFORMANCE TEST (Manual) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .                           HA-   16
PRECAUTIONS FOR REFRIGERANT CONNECTION ..........................                                                                     HA-   18
PIPING. COMPRESSOR MOUNTING AND F.1.C.D .............................                                                                 HA-   19
COMPRESSOR O I L - ForMJS170 ..........................................                                                               HA-   21
COMPRESSOR -Model MJS170 ............................................                                                                 HA-   23
A/C ELECTRICAL CIRCUIT (Manual) ......................................                                                                HA-   28
A/C ELECTRICAL COMPONENTS (Manual) ..................................                                                                 HA-   30
LOCATION OF A/C ELECTRICAL COMPONENTS (Manual) ....................                                                                   HA-   32
TROUBLE DIAGNOSES (Manual) ..........................................                                                                 HA-   33

DESCRIPTION - A i r Conditioner (Auto) ......................................                                                         HA- 65
AIR FLOW AND COMPONENT LAYOUT (Auto) .............................                                                                    HA- 85
LOCATION OF VACUUM COMPONENTS (Auto) .............................                                                                    HA- 87
A/C PERFORMANCE TEST (Auto) .........................................                                                                 HA- 88
A/C PERFORMANCE TEST (Auto)/PIPING (Auto) ............................                                                                HA- 89
A/C ELECTRICAL CIRCUIT (Auto) ........................................                                                                HA- 90
A/C ELECTRICAL COMPONENTS (Auto) ...................................                                                                  HA- 94
LOCATION OF A/C ELECTRICAL COMPONENTS (Auto) .....................                                                                    HA- 95
SELF-DIAGNOSING SYSTEM OF TROUBLE (Auto) ..........................                                                                   HA- 98
TROUBLE DIAGNOSES (Auto) ............................................                                                                 HA-102

SERVICE DATA AND SPECIFICATIONS (S.D.S.) .............................                                                                HA-131
SPECIAL SERVICE TOOLS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .                   ~A-134
                                     GENERAL DESCRIPTION
             Continuously Variable                       -Device    for Distributing Cool Air                               -
              Air Flow Control                             to the Feet during "FACE MODE"
The Tan control amplifier, which utilizes transistor     A vacuum actuator is used in the cool-air distribu-
circuits, continuouslv controls the air flow blown       tion device to remove the hot air directed to the
out by the blower, allowing for selection of the de-     floor area and distribute the optimum air tempera-
sired air flowrate. The fan control amplifier is         ture to the driver's compartment. When the vac-
housed in the blower motor unit. The heat-radiat-        uum switch is turned "ON", part of the outside air
ing plate o f the amplifier is placed in the stream of   (or: part of the cool air on models equipped with
the air flow t o effectively cool the transistors.       air conditioning systems) taken in the vehicle is
                                                         bypassed to the shower duct on the driver's side
  *
       --
      To blower relay

            -.
      Tp control unit
                         -.-- 7
                        -. . -
                                       BLOWER MOTOR
                                                         through the operation of the actuator.

                                                                   F i v e r a y center dun
                                                                                              7
                               1                                                                  rVemilator   bypas duct




                                                                                                   Vacuum switch
           F A N CONTROL AMPLIFIER                                                                 (Floor ventilator Open-Close1
                                             SHP.2556          L(Driver-side)
                                                                o w e r t y pe




                                                                           -JI-J(y
                                                                                                      I1       Vacuum hose




                                                                                                                     SHA230B




                                                    HA-2
AIR FLOW AND COMPONENT LAYOUT (Manual)
                Air Flow




                             I




                                         SHA231B




                HA-3
AIR FLOW AND COMPONENT LAYOUT (Manual)
            Component Layout




                                         SHA7908




                 HA-4
LOCATION OF VACUUM COMPONENTS (Manual)


                             Intake actuator   Actuator lFor defroster door 11


With vacuum actuator1




                                                                   Vacuum w i t c h
                                                                   (For floor mntilator)




                                                                                           Front side




    \Vacuum     tank




                        Vacuum pump motorJ              M                                     SH A980 B




                                   HA-5
                                                  CONTROL
                     Heater and Air Conditioner Control Removal




: Heater and air conditioner control assembly mounting bolts




                                                        HA-6
            HEATER ELECTRICAL CIRCUIT
                             Schematic

                                  BATTERY                           FUSIBLE
                                                                    LINK




 POTENT10
 BALANCE
 RESISTOR




SETTING
POTENT10
             k
             z
             3
             J
                     I A
             k
             z                    ZZL
             8                    aos
                                  U O 4
                                                        FUSE



                     I
                                            FAN
                     I                      RHEOSTAT




                 For ventilator




                                                       LIGHTING SWITCH




                                                                              SHA4178




                                  HA-7
     HEATER ELECTRICAL CIRCUIT
               Wiring Diagram

     1:   L-




 r
-
I
                     :--
                     as
                     SU          SHA990B




                  HA-8
                        DESCRIPTION-Air Conditioner (Manual)
                                                 Refrigeration Cycle

REFRIGERANT FLOW
The refrigerant flows in the standard pattern, that is, through the compressor, the condenser, the receiver
drier, through the evaporator, and back to the compressor.
The refrigerant evaporation through the evaporator coil is controlled by an externally equalized expansion
valve, located inside the evaporator case.

FREEZE PROTECTION              - Compressor control
The compressor cycles on and off t o maintain the evaporator temperature within a specified range. When
the evaporator coil temperature falls below a specified point, the thermo control amplifier interrupts the
compressor operation. When the evaporator coil temperature rises above the specification, the thermo con-
trol amplifier allows compressor operation.
The refrigerant system is protected against excessively high pressure by a pressure relief valve located
between the receiver drier and the condenser. Protection against excessively low pressure (interruption of
compressor operation) i s provided by a low pressure switch, located on the receiver drier.




                                     Condenser




                    Safety   valve
                             refriawant to
                                        ~~




                   atmosphere at pressures
                   h o w apwox. 3,727 kPa                                                       Blower motor
                   138 kglcm', 540 psi).
                   The MIH Cannot be reumd.




                                                          Delivers sprayed refrigerant to the
                        Turns OFF at pressure below       evawrator to facilitate refrigerant
                        196 kPa (2 ke/cm',28 poi)         evaporation and controls the amount
   ow-preoure   witch   cutting compressor wwr supply.    of refriwrant passing the orifics.                   SHA926B




                                                         HA-9
     DISCHARGING, EVACUATING, CHARGING AND CHECKING
                  Precautions                                          Discharging

WARNING:                                             Slowly open the valves to discharge only refriger-
0 Always be careful t h a t refrigerant does not     ant. I f they are opened quickly, compressor oil will
  come in contact with your skin.                    also be discharged.
0 Always wear eye protection when working                                                    To high-pressure
                                                                                             service v d v e
  around the system.
0 Keep refrigerant containers stored below 50