Service Manuals, User Guides, Schematic Diagrams or docs for : . Rare and Ancient Equipment SIMPSON TB9-6625-2352-35 simpson_270,269,260-series_triplett_310,666r,630-series_us-army_tb9-6625-2352-35_calibration_procedure_up-to-6kv_2005_sm

<< Back | Home

Most service manuals and schematics are PDF files, so You will need Adobre Acrobat Reader to view : Acrobat Download Some of the files are DjVu format. Readers and resources available here : DjVu Resources
For the compressed files, most common are zip and rar. Please, extract files with Your favorite compression software ( WinZip, WinRAR ... ) before viewing. If a document has multiple parts, You should download all, before extracting.
Good luck. Repair on Your own risk. Make sure You know what You are doing.




Image preview - the first page of the document
simpson_270,269,260-series_triplett_310,666r,630-series_us-army_tb9-6625-2352-35_calibration_procedure_up-to-6kv_2005_sm


>> Download simpson_270,269,260-series_triplett_310,666r,630-series_us-army_tb9-6625-2352-35_calibration_procedure_up-to-6kv_2005_sm documenatation <<

Text preview - extract from the document
                           *TB 9-6625-2352-35
      DEPARTMENT OF THE ARMY TECHNICAL BULLETIN
CALIBRATION PROCEDURE FOR ANALOG
    MULTIMETERS 0 TO 6000 VOLTS
            (GENERAL)
                   Headquarters, Department of the Army, Washington, DC
                                       3 June 2005
           Distribution Statement A: Approved for public release; distribution is unlimited
            REPORTING OF ERRORS AND RECOMMENDING IMPROVEMENTS
        You can improve this manual. If you find any mistakes or if you know of a way to
        improve these procedures, please let us know. Mail your letter or DA Form 2028
        (Recommended Changes to Publications and Blank Forms) directly to: Commander,
        US Army Aviation and Missile Command, AMSAM-MMC-MA-NP, Redstone Arsenal,
        AL 35898-5000. A reply will be furnished to you. You may also provide DA Form
        2028 information to AMCOM via e-mail, fax, or the World Wide Web. Our fax
        number is DSN 788-6546 or Commercial 256-842-6546. Our e-mail address is
        [email protected]. Instructions for sending an electronic 2028 may be found
        at the back of this manual. For the World Wide Web, use
        https://amcom2028.redstone.army.mil.


                                                                                                      Paragraph   Page
   SECTION           I.    IDENTIFICATION AND DESCRIPTION
                           Test instrument identification ...........................                     1        2
                           Forms, records and reports..................................                   2        2
                           Calibration description .......................................                3        2

                    II.    EQUIPMENT REQUIREMENTS
                           Equipment required ............................................                4        3
                           Accessories required ............................................              5        3

                    III.   CALIBRATION PROCESS
                           Preliminary instructions .....................................                 6         3
                           Equipment setup .................................................              7         4
                           Dc voltage .............................................................       8         4
                           Ac voltage..............................................................       9         4
                           Resistance .............................................................      10         5
                           Dc current .............................................................      11        5
                           Final procedure ....................................................          12        31




_________
   *This bulletin supersedes TB 9-6625-2352-35, dated 15 April 2004.
TB 9-6625-2352-35
                                   SECTION I
                        IDENTIFICATION AND DESCRIPTION

1. Test Instrument Identification.         This bulletin provides instructions for the
calibration of Analog Multimeters 0 to 6000 Volts (General) listed in table 1. The
manufacturers' manuals or TMs were used as the prime data sources in compiling these
instructions. The equipment being calibrated will be referred to as the TI (test instrument)
throughout this bulletin.

    a. Model Variations. Variations among models are described in text, tables and figures.
   b. Time and Technique. The time required for each calibration is approximately 2
hours, using the dc and low frequency technique.
2. Forms, Records, and Reports

   a. Forms, records, and reports required for calibration personnel at all levels are
prescribed by TB 750-25.
   b. Adjustments to be reported are designated (R) at the end of the sentence in which
they appear. When adjustments are in tables, the (R) follows the designated adjustment.
Report only those adjustments made and designated with (R).
3. Calibration Description. TI parameters and performance specifications which
pertain to this calibration are listed in table 1.

                                      Table 1. Test Instrument
                                                             Tables for specifications, calibration
                                Models or              performance limits, and figures for adjustments
     Manufacturers        military designators               Tables                         Figures
          ---                  ME-297//U                       3                                1
          ---                  TS-352( )/U                     4                                2
       Simpson                     260                         5                               ---
       Simpson                    260-3                        6                                3
       Simpson                    260-4                        7                                4
       Simpson                    260-5                        8                                5
       Simpson                     269                         9                               ---
       Simpson               269 Series III                   10                                6
       Simpson                     270                        11                                7
       Triplett                    310                        12                               ---
       Triplett                    630                        13                               ---
       Triplett                  630NA                        14                                8
       Triplett                  630PL                        15                               ---
       Triplett                   666R                        16                               ---




2
                                                                                                     TB 9-6625-2352-35
                                              SECTION II
                                       EQUIPMENT REQUIREMENTS

4. Equipment Required. Table 2 identifies the specific equipment to be used in this
calibration procedure. This equipment is issued with Secondary Transfer Calibration
Standards Set AN/GSM-286, and AN/GSM-287. Alternate items may be used by the
calibrating activity. The items selected must be verified to perform satisfactorily prior to
use and must bear evidence of current calibration. The equipment must meet or exceed the
minimum use specifications listed in table 2. The accuracies listed in table 2 provide a four-
to-one ratio between the standard and TI.

5. Accessories Required. The accessories required for this calibration are common
usage accessories issued as indicated in paragraph 4 above, and are not listed in this
calibration procedure.
                               Table 2. Minimum Specifications of Equipment Required
                                                                                        Manufacturer and model         (part
Common name                     Minimum use specifications1
                                                                                        number)
CALIBRATOR                      Dc voltage:      Range: 0 to 1100 V                     Fluke, Model 5720A (5700A/EP)
                                                 Accuracy: 



◦ Jabse Service Manual Search 2024 ◦ Jabse PravopisonTap.bg ◦ Other service manual resources online : FixyaeServiceinfo