USER MANUAL
                                Programmes' setting TV-2K


Press remote control key MENU. On TV screen appears tables MENU:



           After first pressing         After second pressing            After third pressing
                Picture                        Install                          Setup
                Brightness                     Auto Tune                        Timer
                Contrast                       Manual Tune                      Organize
                Colour                         Fine Tune                        Function
                Sharpness                      Store                            Language




Press the MENU key on remote control 2 times and choose function "Install". Press P- key and choose
"Auto Tune" or "Manual Tune" functions. Press the OK key to enter programs' search mode. When
programme appears, press the MENU key and return to the installation table. Pres the P- key and choose
function "Store". Press the OK key. When installation table appears, choose required programme
number in table "Programe" by using "+", "-" keys, then choose Store and OK.
Press the MENU key to return to the installation table and start setting of the next programme.




                           Control of supply voltages
                  Programme UEBL (PAL) must by turned on TV set




 Parameter name        Parameter        Control element      Measuring place     Measuring
                       value                                                     conditions

 Supply voltage        (106-114)V       VR5O1               D6O7"+"
                                                                                UEBL
                                                                                BRIGHT.SATURAT -31
 Filament voltage       6,O-6,6V        VR5O1               Stand connector
                                                                                CONTRAST -45




                                                -3-
               Regulation and checking of raster parameters' (TV-2K)



 Parameter name        Parameter          Control element    Measuring place        Measuring
                       value                                                        conditions


 4.1 Centering         +6 mm              Hposition             O-63              UEBL PAL GRID
 -horizontal           +4 mm              VPOS 5O               O-15              at 9 gradations
 -vertical                                                                        of brightness


  4.2 Picture size    22.5-24.5            VR5O1                                  UEBL brightness
  -horizontal         windows'             VAMP 5O                                from min. to max.
  -vertical           16.5-18.0
                      windows
                                                               O-63

 4.3 Nonlinear         See user                                                   GRIG at 9
 distortions along     parameters'                                                gradations of
 horizontal and        checking                                                   brightness
 vertical



 4.4 Geometrical                           AS
 distortions


                                        Service modes
Press the service key and the OK key on remote control one time. First service table appears on
the screen. You will have second service table Service V3.0 - after pressing the OK key the
second time and Design table - after pressing one more time. Set the raster parameters visually
by using the remote control keys "+", "-", "P+" and "P-": size, centering, nonlinear and geometrical
distortions.
The other parameters you should    set as indicated in the table.
Service table 1                           Service table 2                        Service table 3
                  14" 20", 21"      Service V3.0      14"TV 20",21"TV       Design
Red     Gain       32   40          Tuner AGC            22         22      AGC Gane            00
DC      Red       064 064           *H Position          31         31      Option 1            48
Green Gain        32    40          *V Pos 50            10         07      Option 2            00
DC      Green     063 063           -V Pos 60            11         11      Option 3            07
Blue    Gain        32 40           *V AMP 50            44         55      * Option 4     09 (11)
DC      Blue      063 063                -V AMP 60       62         62      Option 5            00
Apr.    Threshold 15    15          Bright Max.          63         63      ST Text             00
Logo              6-- 6--           Bright Min.          00         00      H POS OSD 001
                                    Sub. Tint            32         32      V POS OSD 01
                                    -VCO Coarse          05         05      H POS TXT 057
                                    -VCO Fine           039       - 069     V POS TXT 04
                                    -VCO Coarse L1 05               05      Op.4 *09-AV,RGB;
                                    -VCO Fine L1 080               080      Op.4*11-AV1,AV2,RGB

                                                -4-
Specific value of V AMP 50 depends on type picture tube.
* The parameters values are specified during adjusting operations.
- Uncontrolled parameters
The values of parameters should be set as shown in table.
To exit from service mode you should press the service key.

Check value of high voltage. The voltage should be not less than 20.5 kV at maximal brightness
and contrast. The high voltage should not exceed 26.5 kV at 100 