Text preview - extract from the document
1073 & 1084 Channel Amplifiers



Contents

       Introduction                                   1

       High Pass Filter (resistor modification)       1

          Important Note                               1

       Installation                                   2

       Dimensions                                     3

       Power Requirements                             3

          Mains Supply (rack units)                    4
          DC Power Supply Indicators (rack units)      4

       Phantom Power                                  4

       Output Level Control                           4

       Connector Details                              5

       Amplifier Controls                             6

          1073 Module                                  6
          1084 Module                                  7

       Specifications                                 8

          1073 and 1084 Modules                        8

       Recall Sheets                                  9

          1073 - Vertical Module                       9
          1073 - Horizontal Module                    10
          1084 - Vertical Module                      11
          1084 - Horizontal Module                    12

       Service Information                            13

          Schematic Drawing Index - 1073/1084 Racks   13
          Schematic Drawing Index - 1073 Module       13
          Schematic Drawing Index - 1084 Module       14




User Guide Issue 5                                         Page i
1073 & 1084 User Manual                                                                       AM5028



Introduction

        These 45 series modules are the same as the original designs, and contain all of the original
        components.

     1073 Channel Amplifiers

        These very popular sounding mic pre's are considered by many to capture the very essence of the
        Neve sound. In manufacture since the early 1970s, the Class A design offers 3 bands of EQ with
        one fixed high frequency and a high pass filter.

     1084 Channel Amplifiers

        Based on the same technology as the 1073s, the 1084s again deliver the unique sound and quality
        of Neve. However, the 1084s offer additional features, including 3 switchable EQ bands with cut
        and boost, a high Q for presence and low pass/high pass filters.



High Pass Filter (resistor modification)

Important Note
        The high pass filter in both the 1073 & 1084 modules is a passive design and as such must be
        correctly terminated to achieve a maximally flat response.

        In order to achieve this there is a 5k1 resistor fitted inside the module on the back connector
        between pin E (0v) and pin K (fader send) see diagram below:




        In situations where the fader connection is not used (most Neve 45 series consoles except
        BCM10's) then the resistor remains in place.

        In situations where the fader connection is used (BCM10's and AMS Neve 1073/1084 racks)
        then the 5k1 resistor should be disconnected and replaced with a fader or potentiometer whose
        value is 4k7 / 5k ohms.

        Failure to do so will result in incorrect levels and uneven frequency response.




User Guide Issue 5                                                                              Page 1
1073 & 1084 User Manual                                                                          AM5028



Installation

        The 1073s and 1084s are available as stand-alone modules, or in a choice of two housings.

        The 3U rack houses two modules mounted horizontally in a 19" rack-mounting unit.

        The 5U rack houses eight modules mounted vertically in a 19" rack-mounting unit.

        Both have rear panels with XLRs for transformer balanced I/O.

        The 3U rack rear panel has a fused, voltage selector IEC mains input connector. The 5U rack has a
        free standing AC supply with a fused, voltage selector IEC mains input connector and connects to
        the rack via a connector and a 1.5 meter cable.

        Modules of any combination can be fitted into a rack unit.




                     Example: 5U Rack fitted with1084 modules



Additional Information

        *Rack Mount Instructions *_
           A) Elevated Operating Ambient - If installed in a closed or multi-unit rack assembly, the
           operating ambient temperature of the rack environment may be greater than room ambient.
           Therefore, consideration should be given to installing the equipment in an environment
           compatible with the maximum ambient temperature (Tma) specified by the manufacturer.
           B) Reduced Air Flow - Installation of the equipment in a rack should be such that the amount of
           air flow required for safe operation of the equipment is not compromised.
           C) Mechanical Loading - Mounting of the equipment in the rack should be such that a hazardous
           condition is not achieved due to uneven mechanical loading.
           D) Circuit Overloading - Consideration should be given to the connection of the equipment to
           the supply circuit and the effect that overloading of the circuits might have on overcurrent
           protection and supply wiring. Appropriate consideration of equipment nameplate ratings
           should be used when addressing this concern.


           E) Reliable Earthing - Reliable earthing of rack-mounted equipment should be maintained.
           Particular attention should be given to supply connections other than direct connections to the
           branch circuit (e.g. use of power strips).



        Recommended Tma = 50 deg C



User Guide Issue 5                                                                                Page 2
1073 & 1084 User Manual                                                                   Dimensions




        Mains Voltage Adjustment

        1.) Switch off unit.

        2.)   Remove fuse.

        3.) Turn inner barrel with screwdriver or coin until correct voltage figure is under the white
        arrow on the housing.

        4.) Replace fuse.




Dimensions


     Stand-alone Modules             Width           Height            Depth             Approx.
                                   mm (inches)      mm (inches)      mm (inches)         Weight
                                                                                         kg (lbs)
         1073 Module                 45 (1.8)        222 (8.75)        254 (10)          2.5 (5.5)
         1084 Module                 45 (1.8)        222 (8.75)        254 (10)          2.5 (5.5)




        19" Rack Mounting               U         Depth            Height           Approx. Weight
                                                mm (inches)       mm (inches)          kg (lbs)
         2 Module Version               3         405 (16)          133 (5.25)         11 (24.2) *
         8 Module Version               5         405 (16)          222 (8.75)          30 (66) *

        * Fully populated rack




User Guide Issue 5                                                                             Page 3
1073 & 1084 User Manual                                                                Power Requirements




Power Requirements

                     Rack Units                        3U                         5U
         Rated Voltage                      100-230V AC                100-230V AC
         Rated Frequency                    50-60 Hz                   50-60Hz
         Rated Current                      0.5A Max                   0.8A Max


         Primary Protection Fuse:
         Operating Voltage                  100-230V AC                100-230V AC
         Fuse Rating and Type               T0.5A H 250V               T1A H 250V
                                            20mm x 5mm CERAMIC         20mm x 5mm CERAMIC
         Location                           IEC Mains connector        IEC Mains connector
         Secondary Protection Fuse:
         Output Voltage                                                24V DC
         Fuse Rating and Type                                          T 2.0A L 250V
                                                                       20mm x 5mm GLASS
         Location                                                                 F1
         Output Voltage                                                48V DC
         Fuse Rating and Type                                          T 250mA L 250V
                                                                       20mm x 5mm GLASS
         Location                                                                 F2


                     Modules                                      Power
                    1073 Module                 106mA 