Service Manuals, User Guides, Schematic Diagrams or docs for : Minolta Copiers CF3101 LINKFILE DF-332-sequence

<< Back | Home

Most service manuals and schematics are PDF files, so You will need Adobre Acrobat Reader to view : Acrobat Download Some of the files are DjVu format. Readers and resources available here : DjVu Resources
For the compressed files, most common are zip and rar. Please, extract files with Your favorite compression software ( WinZip, WinRAR ... ) before viewing. If a document has multiple parts, You should download all, before extracting.
Good luck. Repair on Your own risk. Make sure You know what You are doing.




Image preview - the first page of the document
DF-332-sequence


>> Download DF-332-sequence documenatation <<

Text preview - extract from the document
Single-sided mode with 4 documents (1/4)

                                                                                                                    1st Original Exchange to Complete
                                                                                                                    2nd Original Preliminary Take-up Start
                                       1st Original Preliminary Take-up Start            1st Original
                                       Misted Original Detecting Signal Start                                                                                       2nd Original
                                                                                         Exchange to Start     2nd Original Preliminary Take-up Complete
                                                                                                                                                                    Exchange to Start

                            on
/SCEND                      off
                            on
/DSET                       off                                                                              DSET Signal Transmission
                                                                          104ms   61ms                                                              104ms    61ms
                  High CW
Take up      (M1) Low off
Motor             Low
                  High CCW                  On Registration                                                             On Registration
                                            Amount of Registration Loop 6[mm]                                           Amount of Registration Loop 6[mm]
                                                                                                             86ms
               High CW
Transport (M2) Low off
Motor          Low
               High CCW

                  High CW            50ms
Registration      Low
             (M3) Low off
Motor
                  High CCW
                     With Paper
Empty Sensor(PC4)
                     Without Paper
                             on
Registration Sensor(PC1)
                             off
                             on
Pick up Sensor(PC2)
                             off
                             on
Turnover Sensor(PC5)
                             off
                             on
Exit Sensor(PC6)
                             off
                                              705ms                                                                       705ms
                             on
Registration Clutch(CL1)
                             off
                                                              766ms
                             on
Exit Solenoid(SL2)
                             off
                             on
Turnover Solenoid(SL1)
                             off
                                                                                    Original Exchange Time              Preliminary Take-up Time
900mm/sec=High                                                                               384ms                                 952ms
150mm/sec=Low
Single-sided mode with 4 documents (2/4)



                                                                     3rd Original Preliminary Take-up Complete
                                     2nd Original             1st Original Exchange to Complete
                                                                                                                        3rd Original Exchange to Start
                                     Exchange to Start        3rd Original Preliminary Take-up Start

                            on
/SCEND                      off
                            on
/DSET                       off                               DSET Signal Transmission
                                                                                                       104ms     61ms
                            CW
Take up      (M1)           off
Motor
                            CCW                                              On Registration
                                                              86ms           Amount of Registration Loop 6[mm]
                            CW
Transport (M2)              off
Motor
                            CCW

                            CW
Registration
             (M3)           off
Motor
                            CCW
                     With Paper
Empty Sensor(PC4)
                     Without Paper
                             on
Registration Sensor(PC1)
                             off
                             on
Pick up Sensor(PC2)
                             off
                             on
Turnover Sensor(PC5)
                             off
                             on
Exit Sensor(PC6)
                             off
                             on                                               705ms
Registration Clutch(CL1)
                             off
                             on
Exit Solenoid(SL2)
                             off
                             on
Turnover Solenoid(SL1)
                             off
                                     Original Exchange Time           Preliminary Take-up Time
                                              384ms                              952ms
Single-sided mode with 4 documents (3/4)


                                       3rd Original Exchange to Start                                                                           4th Original Exchange to Start                                   3rd Original Exit to Start
                                       1st Original Exit to Start           4th Original Preliminary Take-up Start
                                                                                                                                                2nd Original Exit to Start                  2nd Original Exit to Complete
                                                              3rd Original Exchange to Complete                           1st Original Exit
                                                                                                                                                                       4th Original Exchange to Complete
                                                              4th Original Preliminary Take-up Start                      to Complete

                            on
/SCEND                      off
                            on
/DSET                       off                               DSET Signal Transmission                                                                                 DSET Signal Transmission
                                                                                                           104ms       61ms
                            CW
Take up      (M1)           off
Motor
                            CCW                                             On Registration
                                                              86ms          Amount of Registration Loop 6[mm]                                                          88ms
                            CW
Transport (M2)              off
Motor
                            CCW
                                                                82ms      181ms                                315ms                                                     82ms   181ms                             315ms
                            CW
Registration
             (M3)           off
Motor
                            CCW
                     With Paper
Empty Sensor(PC4)
                     Without Paper
                             on
Registration Sensor(PC1)
                             off
                             on
Pick up Sensor(PC2)
                             off
                             on
Turnover Sensor(PC5)
                             off
                             on
Exit Sensor(PC6)
                             off
                                                                                  705ms
                             on
Registration Clutch(CL1)
                             off
                             on
Exit Solenoid(SL2)
                             off
                             on
Turnover Solenoid(SL1)
                             off

                                     Original Exchange Time                    Preliminary Take-up Time                                       Original Exchange Time
                                             384ms                                        952ms                                                        384ms
                                                               Original Exit Time                                                                                                Original Exit Time
                                                                        1397ms                                                                                                          1397ms
Single-sided mode with 4 documents (4/4)




                                     3rd Original Exit to Start                                3rd Original Exit to Complete                                4th Original Exit to Complete
                                                                                               4th Original Exit to Start

                            on
/SCEND                      off
                            on
/DSET                       off
                            CW
Take up      (M1)           off
Motor
                            CCW
                            CW
Transport (M2)              off
Motor
                            CCW
                                                              82ms   181ms             315ms                         82ms      181ms                315ms
                            CW
Registration
             (M3)           off
Motor
                            CCW
                     With Paper
Empty Sensor(PC4)
                     Without Paper
                             on
Registration Sensor(PC1)
                             off
                             on
Pick up Sensor(PC2)
                             off
                             on
Turnover Sensor(PC5)
                             off
                             on
Exit Sensor(PC6)
                             off
                             on
Registration Clutch(CL1)
                             off
                             on
Exit Solenoid(SL2)
                             off
                             on
Turnover Solenoid(SL1)
                             off
                                                                  Original Exit Time                                           Original Exit Time
                                                                        1397ms                                                         1397ms
Double-sided mode with 3 documents (1/7)

                                                                                                                1st Original Exchange to Complete
                                                                                                                2nd Original Preliminary Take-up Start
                                      1st Original Preliminary Take-up Start             1st Original            2nd Original Preliminary Take-up Complete          1st Original (Reverse Side)
                                      Misted Original Detecting Signal Start             Exchange to Start                                                          Exchange to Complete

                            on
/SCEND                      off
                            on
/DSET                       off                                                                               DSET Signal Transmission
                                                                          104ms   61ms                                                              104ms    61ms
                  High CW
Take up      (M1) Low off
Motor             Low
                  High CCW                    On Registration                                                            On Registration
                                              Amount of Registration Loop 6[mm]                               86ms       Amount of Registration Loop 6[mm]
               High CW
Transport (M2) Low off
Motor          Low
               High CCW

                  High CW            50ms
Registration      Low
             (M3) Low off
Motor
                  High CCW
                     With Paper
Empty Sensor(PC4)
                     Without Paper
                             on
Registration Sensor(PC1)
                             off
                             on
Pick up Sensor(PC2)
                             off
                             on
Turnover Sensor(PC5)
                             off
                             on
Exit Sensor(PC6)
                             off
                                               705ms                                                                      705ms
                             on
Registration Clutch(CL1)
                             off
                                                               766ms
                             on
Exit Solenoid(SL2)
                             off
                             on
Turnover Solenoid(SL1)
                             off

                                                                                     Original Exchange Time            Preliminary Take-up Time
                                                                                              384ms                               952ms
Double-sided mode with 3 documents (2/7)



                                     1st Original (Reverse Side) Exchange to Start         1st Original (Reverse Side) Exchange to Complete   2nd Original
                                                                                                                                              Exchange to Start
                            on
/SCEND                      off
                            on
/DSET                       off
                  High CW
Take up      (M1) Low off
Motor             Low
                  High CCW
                                                              103ms                456ms
                  High CW
Transport    (M2) Low off
Motor             Low
                  High CCW
                                                              97ms             150ms
                  High CW
Registration      Low
             (M3) Low off
Motor
                  High CCW
                     With Paper
Empty Sensor(PC4)
                     Without Paper
                             on
Registration Sensor(PC1)
                             off
                             on
Pick up Sensor(PC2)
                             off
                             on
Turnover Sensor(PC5)
                             off
                             on
Exit Sensor(PC6)
                             off
                             on
Registration Clutch(CL1)
                             off
                             on
Exit Solenoid(SL2)
                             off
                                                               563ms
                             on
Turnover Solenoid(SL1)                                                         133ms
                             off

                                                   Reverse side Original Exchange Time
                                                                      1330ms
Double-sided mode with 3 documents (3/7)


                                                                                                                                                   3rd Original Preliminary Take-up Complete
                                        2nd Original Exchange to Start             2nd Original Exchange to Complete        1st Original Exit                       2nd Original (Reverse Side)
                                        1st Original Exit to Start                 3rd Original Preliminary Take-up Start   to Complete                             Exchange to Start

                             on
 /SCEND                      off
                             on
 /DSET                       off
                                                                                                               104ms                            61ms
                   High CW
 Take up      (M1) Low off
 Motor             Low
                   High CCW                                                                     On Registration
                                                                                  86ms          Amount of Registration Loop 6[mm]
                High CW
 Transport (M2) Low off
 Motor          Low
                High CCW
                                                                      181ms                                315ms
                   High CW
 Registration      Low
              (M3) Low off
 Motor
                   High CCW
                      With Paper
 Empty Sensor(PC4)
                      Without Paper
                              on
 Registration Sensor(PC1)
                              off
                              on
 Pick up Sensor(PC2)
                              off
                              on
 Turnover Sensor(PC5)
                              off
                              on
 Exit Sensor(PC6)
                              off
                                                                                                705ms
                              on
 Registration Clutch(CL1)
                              off
                                                          939ms
                              on
 Exit Solenoid(SL2)                   20ms
                              off
                              on
 Turnover Solenoid(SL1)
                              off
                                             Original Exchange Time                            Preliminary Take-up Time
                                                     730ms                                                  952ms
                                                                       Original Exit Time
                                                                              1365ms
Double-sided mode with 3 documents (4/7)




                                     2nd Original (Reverse Side) Exchange to Start           2nd Original (Reverse Side) Exchange to Complete   1st Original
                                                                                                                                                Exchange to Start
                            on
/SCEND                      off
                            on
/DSET                       off
                            CW
Take up      (M1)           off
Motor
                            CCW
                                                             103ms                   456ms
                            CW
Transport (M2)              off
Motor
                            CCW
                                                             97ms           150ms
                            CW
Registration
             (M3)           off
Motor
                            CCW
                     With Paper
Empty Sensor(PC4)
                     Without Paper
                             on
Registration Sensor(PC1)
                             off
                             on
Pick up Sensor(PC2)
                             off
                             on
Turnover Sensor(PC5)
                             off
                             on
Exit Sensor(PC6)
                             off
                             on
Registration Clutch(CL1)
                             off
                             on
Exit Solenoid(SL2)
                             off
                                                              563ms
                             on
Turnover Solenoid(SL1)                                                     563ms
                             off
                                                   Reverse side Original Exchange Time
                                                                1330ms
Double-sided mode with 3 documents (5/7)

                                     3rd Original Exchange to Start              3rd Original Exchange to Complete   2nd Original Exit to Complete   3rd Original (Reverse Side)
                                     2nd Original Exit to Start                                                                                      Exchange to Start

                            on
/SCEND                      off
                            on
/DSET                       off
                  High CW
Take up      (M1) Low off
Motor                Low
                     High CCW
                                                                                86ms
                  High CW
Transport    (M2) Low off
Motor             Low
                  High CCW
                                                                181ms                                315ms
                  High CW
Registration      Low
             (M3) Low off
Motor
                  High CCW
                     With Paper
Empty Sensor(PC4)
                     Without Paper
                             on
Registration Sensor(PC1)
                             off
                             on
Pick up Sensor(PC2)
                             off
                             on
Turnover Sensor(PC5)
                             off
                             on
Exit Sensor(PC6)
                             off
                             on
Registration Clutch(CL1)
                             off
                                                       939ms
                             on
Exit Solenoid(SL2)                   20ms
                             off
                             on
Turnover Solenoid(SL1)
                             off
                                        Original Exchange Time
                                                 730ms
                                                           Original Exit Time
                                                                  1365ms
Double-sided mode with 3 documents (6/7)


                                     3rd Original (Reverse Side) Exchange to Start             3rd Original (Reverse Side) Exchange to Complete   3rd Original Exit to Start


                            on
/SCEND                      off
                            on
/DSET                       off
                            CW
Take up      (M1)           off
Motor
                            CCW
                                                              103ms                    456ms
                            CW
Transport (M2)              off
Motor
                            CCW
                                                               97ms            150ms
                            CW
Registration
             (M3)           off
Motor
                            CCW
                     With Paper
Empty Sensor(PC4)
                     Without Paper
                             on
Registration Sensor(PC1)
                             off
                             on
Pick up Sensor(PC2)
                             off
                             on
Turnover Sensor(PC5)
                             off
                             on
Exit Sensor(PC6)
                             off
                             on
Registration Clutch(CL1)
                             off
                             on
Exit Solenoid(SL2)
                             off
                                                               563ms
                             on
Turnover Solenoid(SL1)                                                         133ms
                             off

                                                    Reverse side Original Exchange Time
                                                                      1330ms
Double-sided mode with 3 documents (7/7)



                                      3rd Original Exit to Start                           3rd Original Exit to Complete


                            on
/SCEND                      off
                            on
/DSET                       off
                            CW
Take up      (M1)           off
Motor
                            CCW
                            CW
Transport (M2)              off
Motor
                            CCW
                                                                   181ms           315ms
                            CW
Registration
             (M3)           off
Motor
                            CCW
                     With Paper
Empty Sensor(PC4)
                     Without Paper
                             on
Registration Sensor(PC1)
                             off
                             on
Pick up Sensor(PC2)
                             off
                             on
Turnover Sensor(PC5)
                             off
                             on
Exit Sensor(PC6)
                             off
                             on
Registration Clutch(CL1)
                             off
                                                      939ms
                             on
Exit Solenoid(SL2)                   20ms
                             off
                             on
Turnover Solenoid(SL1)
                             off
                                                              Original Exit Time
                                                                    1365ms



◦ Jabse Service Manual Search 2024 ◦ Jabse PravopisonTap.bg ◦ Other service manual resources online : FixyaeServiceinfo