Text preview - extract from the document
                                                                      MINOLTA CO., LTD., SERVICE ENGINEERING DIVISION

                                                                                                         PAGE NO. : 1/1
                 SERVICE BULLETIN
                                                                      PROBLEM            FUNCTION             SAFETY

                                                                                       SERVICEABILITY         OTHERS

MODEL NAME :     Di620                                                 OTHERS          PERFORMANCE          CORRECTION

                                                                                     SAFETY REGULATION        OTHERS
MODEL CODE :     1155
         NO. :   009B
       DATE :    981001
    SUBJECT :    CORRECTION OF SERVICE MANUAL


Please amend your Service Manual according to the instructions given below.

GENERAL, MECHANICAL/ELECTRICAL

Page: M-121



 ADDITION


18-7. Mechanism and Control of Fusing Roller Small-Amount Turning
      If the Upper and Lower Fusing Rollers are kept in the temperature-controlled stage for more than a given
      period of time, the areas of the two rollers in contact with each other are deformed by heat and pressure. To
      prevent this situation, the rollers are automatically driven for a given period of time to change the areas of the
      rollers in contact with each other.



                                         Warm-up Completed



           Fusing Roller Temperature
           Control


           Fusing Motor (M3)



                                                   T1: 240min       T2: 63ms




                                                                                             PCJ-242iA PRINTED IN JAPAN