Service Manuals, User Guides, Schematic Diagrams or docs for : Agilent 5990-4341EN N9000A CXA X-Series Signal Analyzer - Configuration Guide c20140923 [12]
<< Back |
HomeMost service manuals and schematics are PDF files, so You will need Adobre Acrobat Reader to view : Acrobat Download
Some of the files are DjVu format. Readers and resources available here : DjVu Resources
For the compressed files, most common are zip and rar. Please, extract files with Your favorite compression software ( WinZip, WinRAR ... ) before viewing.
If a document has multiple parts, You should download all, before extracting.
Good luck. Repair on Your own risk. Make sure You know what You are doing.
Image preview - the first page of the document
>> Download 5990-4341EN N9000A CXA X-Series Signal Analyzer - Configuration Guide c20140923 [12] documenatation <<Text preview - extract from the documentKeysight Technologies
CXA X-Series Signal Analyzer
N9000A
Configuration Guide
Configure Your Keysight CXA Signal Analyzer
This CXA configuration guide will help you determine which performance options, measurement applications,
accessories, and services to include with your new CXA or to add as upgrades to an existing CXA.
This step-by-step process will help you custom-configure your CXA signal analyzer. Capabilities that are listed as
standard come with the instrument at no additional charge. Tailor the performance, exterior, and service packages
to meet your requirements. Ordering optional capabilities at time of purchase provides the lowest overall cost.
For detailed specifications, refer to the CXA Signal Analyzer Specification Guide (N9000-90016). For a summary of
specifications, refer to the CXA Signal Analyzer Data Sheet (5990-4327EN).
Step 1. Select maximum frequency range (required option; frequency range not upgradeable)
Description Option number Additional information
Frequency range, 9 kHz to 3.0 GHz N9000A-503
Frequency range, 9 kHz to 7.5 GHz N9000A-507
Frequency range, 9 kHz to 13.6 GHz N9000A-513
Frequency range, 9 kHz to 26.5 GHz N9000A-526
Step 2. Add a preamplifier
Description Option number Additional information: Preamplifiers improve the noise floor for
low-level signal detection; +20 dB: 100 kHz to 26.5 GHz
Preamplifier, 100 kHz to 3.0 GHz N9000A-P03 Compatible with N9000A-503, N9000A-507, N9000A-513,
and N9000A-526
Preamplifier, 100 kHz to 7.5 GHz N9000A-P07 Compatible with N9000A-507, N9000A-513, and N9000A-526
Preamplifier, 100 kHz to 13.6 GHz N9000A-P13 Compatible with N9000A-513 and N9000A-526
Preamplifier, 100 kHz to 26.5 GHz N9000A-P26 Compatible with N9000A-526
Step 3. Choose frequency reference
Description Option number Additional information
Frequency reference Standard Aging rate: