Service Manuals, User Guides, Schematic Diagrams or docs for : Agilent 5990-4341EN N9000A CXA X-Series Signal Analyzer - Configuration Guide c20140923 [12]

<< Back | Home

Most service manuals and schematics are PDF files, so You will need Adobre Acrobat Reader to view : Acrobat Download Some of the files are DjVu format. Readers and resources available here : DjVu Resources
For the compressed files, most common are zip and rar. Please, extract files with Your favorite compression software ( WinZip, WinRAR ... ) before viewing. If a document has multiple parts, You should download all, before extracting.
Good luck. Repair on Your own risk. Make sure You know what You are doing.




Image preview - the first page of the document
5990-4341EN N9000A CXA X-Series Signal Analyzer - Configuration Guide c20140923 [12]


>> Download 5990-4341EN N9000A CXA X-Series Signal Analyzer - Configuration Guide c20140923 [12] documenatation <<

Text preview - extract from the document
Keysight Technologies
CXA X-Series Signal Analyzer
N9000A




        Configuration Guide
Configure Your Keysight CXA Signal Analyzer

This CXA configuration guide will help you determine which performance options, measurement applications,
accessories, and services to include with your new CXA or to add as upgrades to an existing CXA.

This step-by-step process will help you custom-configure your CXA signal analyzer. Capabilities that are listed as
standard come with the instrument at no additional charge. Tailor the performance, exterior, and service packages
to meet your requirements. Ordering optional capabilities at time of purchase provides the lowest overall cost.

For detailed specifications, refer to the CXA Signal Analyzer Specification Guide (N9000-90016). For a summary of
specifications, refer to the CXA Signal Analyzer Data Sheet (5990-4327EN).



 Step 1. Select maximum frequency range (required option; frequency range not upgradeable)
 Description                           Option number            Additional information
 Frequency range, 9 kHz to 3.0 GHz     N9000A-503
 Frequency range, 9 kHz to 7.5 GHz     N9000A-507
 Frequency range, 9 kHz to 13.6 GHz    N9000A-513
 Frequency range, 9 kHz to 26.5 GHz    N9000A-526

 Step 2. Add a preamplifier
 Description                            Option number          Additional information: Preamplifiers improve the noise floor for
                                                               low-level signal detection; +20 dB: 100 kHz to 26.5 GHz
 Preamplifier, 100 kHz to 3.0 GHz       N9000A-P03             Compatible with N9000A-503, N9000A-507, N9000A-513,
                                                               and N9000A-526
 Preamplifier, 100 kHz to 7.5 GHz       N9000A-P07             Compatible with N9000A-507, N9000A-513, and N9000A-526
 Preamplifier, 100 kHz to 13.6 GHz      N9000A-P13             Compatible with N9000A-513 and N9000A-526
 Preamplifier, 100 kHz to 26.5 GHz      N9000A-P26             Compatible with N9000A-526

 Step 3. Choose frequency reference
 Description                            Option number          Additional information
 Frequency reference                    Standard               Aging rate: 