Service Manuals, User Guides, Schematic Diagrams or docs for : Agilent 5990-7532EN Time Sidelobe Measurements to see Performance of Compressed-Pulse Radars - Application Note c20140725 [7]

<< Back | Home

Most service manuals and schematics are PDF files, so You will need Adobre Acrobat Reader to view : Acrobat Download Some of the files are DjVu format. Readers and resources available here : DjVu Resources
For the compressed files, most common are zip and rar. Please, extract files with Your favorite compression software ( WinZip, WinRAR ... ) before viewing. If a document has multiple parts, You should download all, before extracting.
Good luck. Repair on Your own risk. Make sure You know what You are doing.




Image preview - the first page of the document
5990-7532EN Time Sidelobe Measurements to see Performance of Compressed-Pulse Radars - Application Note c20140725 [7]


>> Download 5990-7532EN Time Sidelobe Measurements to see Performance of Compressed-Pulse Radars - Application Note c20140725 [7] documenatation <<

Text preview - extract from the document
Keysight Technologies
Solutions for Using Time Sidelobe Measurements to
Assess the Performance of Compressed-Pulse Radars




                                    Application Note
                                    Radar Measurement Series
Overview                                                                  the effect of such a reflection when evaluating the overall functional
                                                                          performance of a frequency chirped, pulse compression radar.
In a radar system, the use of modulation on pulse for "compression"
provides enhanced spatial resolution as well as extended range for a        Pulse compression radar

given output power level. Consequently, this technique is widely used                                   Waveform
                                                                                                         exciter
                                                                                                                       DAC                               PA
                                                                                                                                                                Transmitter


in current- and next-generation radar systems.                                                                                                                                Antenna
                                                                                                                   STALO
                                                                                                    COHO

Unfortunately, traditional RF pulse measurements become less
effective predictors of performance in radars that use pulse                I       Synchronous
                                                                                                                             IF                           LNA
                                                                            Q       I/Q detector
compression. For example, the width of an uncompressed radar                                                                                                      Receiver


pulse is directly related to spatial resolution. In contrast, the




                                                                                         Mismatch




                                                                                                                                        Mismatch
resolution depends on pulse width, chirp bandwidth and chirp
linearity in a compressed radar system that uses linear frequency
modulated (LFM) chirp pulses.

Within the field of radar development, a technique called the time                                  Reflection             Reflection

sidelobe level (SSL) measurement has emerged as a viable solution                                                                                  Internally generated echo
to predict performance. This method distills a wide range of potential
signal impairments down to a simple metric that can be used to
determine if radar performance will fit the intended application.         Figure 1. Mismatch reflections may cause ghost echo returns

This application brief defines key problems related to measurements
                                                                          Other problems from within the radar may involve other component
of compressed-pulse radars, describes the time sidelobe method, and
                                                                          impairments that can affect the results at the demodulator.
outlines the practical uses of this approach.
                                                                          Examples include unintended phase noise, amplitude modulation,
Problem                                                                   reflections and group delay. These routinely distort what is actually
                                                                          detected in the receiver, limiting the dynamic range and detection
As suggested above, the modulation parameters used in compressed          accuracy of the radar.
radars clearly affect system performance. One of the overall problems
is in the determination of "what's good enough?" with regard to the
attributes of components used to build radar subsystems. Similarly,
in a diagnostic scenario, it is difficult to assess overall performance
without separately measuring the traits of individual components.

As an example, it can be difficult to judge the affect of component
performance on any impairment added to a modulated pulse--and
errors in these measurements routinely result in costly over-specifying
of components. Consider a frequency-dependent mismatch reflection
of an IF filter used in a radar receiver (Figure 1). Typically, lower-
frequency IF filters have significant signal delays. When these
combine with internal reflections from a desired radar pulse the result
may be a "ghost" echo return. It might be very difficult to determine
Solution                                                                  Windowing functions
                                                                          Amplitude weighting of the output signals is generally used to
One way to meet these challenges is to distill the characterization       reduce the time sidelobes to an acceptable level. As a side effect
of a wide range of potential signal impairments down to a simple          the signal weighting will result in the loss of signal to noise ratio.
metric, preferably one that can be used to determine if radar             Some of the more commonly used windowing functions are shown
performance will fit the intended application. Time sidelobe
                                                                          in table 1 with their suppression levels and signal to noise losses.
measurements provide an effective way to use known-good
test equipment--with internal impairments calibrated out of the           Table 1. Popular windowing functions and their effects
measurements--and mathematically consistent processing of
measurement data to accurately characterize the performance of a           Weighting                     Peak Sidelobe        S/N Loss (dB)
compressed-pulse radar.                                                    Function                      Level (dB)
                                                                           Uniform                              -13.2                 0
What are time sidelobes?                                                   Hamming                              -42.8                1.34
Sometimes referred to as range sidelobes, time sidelobes are a             Hann                                  -32                 1.4
result of using pulse compression techniques. They are produced            Blackman                              -58                 2.37
when the ideal radar return is convolved with the response of the
                                                                           Blackman-Harris (3 term)              -67                 2.33
less than ideal correlation filter during the compression process
or when a non-deal radar return is convolved with the response
of the less than ideal correlation filter or some combination of          Figure 2 graphically shows the characteristics of the Hamming
the two. This causes some of the energy in the return pulse to lie        function.
outside the pulse bandwidth. In the time domain this is indicated
by a spreading in range (time) of the return pulse, particularly in
the presence of ground clutter or transmit signal anomalies caused
by imperfections in the transmitter path.

Since the correlation filter in modern radar is nearly always
implemented digitally within a DSP rather than with an analog
Standing Acoustic Wave (SAW) filter, the resulting compressed
pulse waveform is mathematically deterministic and repeatable
and as such, easily optimized through simulation.




Figure 2. Hamming windowing function and associated frequency response




                                                                      2
     F ( t ) = A cos( wc t + 1 ut 2 )
                             2
                                                                                                               Time side lobe level
                                                                                                             (SLL) is a quality metric

                                                        Pulse                                                                              Compressed
                                                        width                                                                              pulse width
                                                                                                                SLL

                                                                  Correlation
                                                                     filter

              Linear FM chirp pulse                                                                                Compressed pulse

Figure 3. Pulse compression and the Time Side Lobe Measurement


Applying the time sidelobe method                                         SLL measurements made. The pulse generation platform should
                                                                          provide repeatability when creating and recreating the pulses
The detector in a radar receiver correlates the transmitted signal
                                                                          for the measurement stimulus and for the relative comparison
with echoes and noise received over time. When the received
                                                                          measurement.
signal matches the sent signal a correlation peak occurs and
target detection is marked at that time.1                                 Alternatively, the ideal compressed pulse could simply be created
                                                                          mathematically and compared to the measured pulse without
An ideal correlation peak would be infinitely narrow, have a value        ever physically generating it. The limitation here is that the relative
of one, and be surrounded by noise-like sidelobe levels. At the           comparison is always with the ideal which may not always be
other extreme, the correlation between a pure signal and pure             desired. At times there may be a need to measure SSL between
noise is zero. Figure 3 indicates the process of pulse compression        two points within the system in trying to track down the specific
and the time sidelobe measurement.                                        source of an anomaly.
System impairments ranging from imperfectly generated
compressed pulses to internal reflections from filters can cause              Three tools suggested for creating the pulsed waveform may use
                                                                              different methods but the end result is the same: a combined or
correlation sidelobe levels well above the noise floor (Figure 4).            separate I and Q waveform file(s) that can be directly downloaded into
Because it is difficult to judge the effect of such impairments on            the waveform memory of an Arbitrary Waveform Generator (AWG).
a compressed pulse, using the time sidelobe level technique
provides quantitative measurements of transmitted pulse shapes                SystemVue: A system modeling tool, SystemVue with the optional radarmodel
                                                                              library provides signal processing reference models for exploring trade-offs in
and received signals.                                                         radar system architectures for Pulsed Doppler, FMCW, Digital Array, and UWB
                                                                              Radars. It enables scenario modeling by adding targets, clutter, fading, noise,
An accurate measurement of SLL requires a filter that is perfectly            interferers, and the RF effects necessary for realistic system analysis and early
correlated to the desired pulse shape. The first step is to build an          R&D verification using connections to live test equipment.
                                                                              www.keysight.com/find/SystemVue
ideal waveform that represents the desired compressed pulse:
bandwidth, pulse width, and chirp or modulation characteristics
                                                                              Signal Studio for pulse building: Enables flexible generation of complex,
are essential parameters. Modeling can be performed with                      wideband pulse patterns using the E8267D PSG or E4438C ESG vector signal
software such as SystemVue or Signal Studio for pulse building                generators. Custom pulse shaping, modulation, antenna patterns, and user-
from Keysight Technologies, Inc. or MATLAB from The MathWorks.                defined pulse patterns are easily achieved with the straightforward graphical user
                                                                              interface or with your own test executive using the COM-based API. Add the
The mathematically generated, ideal (i.e., repeatable with no                 N603xA/N824xA/M933xA wideband AWG to Signal Studio for pulse building
impairments added) representation of the compressed pulse can                 such as signal processing, signal modulation, digital filtering, and curve fitting.
be stored in memory and recalled later to correlate measured                  www.keysight.com/find/signalstudio
waveforms and enable calculations of SLL.
                                                                              MATLAB: A software environment and programming language created by
                                                                              MathWorks and now available directly from Keysight as an option with most sig-
The FM chirp pulse waveform for the SLL measurement and                       nal generators and signal analyzers. MATLAB extends the capabilities of Keysight
calculation should be designed to imitate the operational                     signal analyzers and generators to make custom measurements, analyze and visu-
waveform of the radar system. For systems that feature multiple               alize data, create arbitrary waveforms, control instruments, and build test systems.
                                                                              It provides interactive tools and command-line functions for data analysis tasks
operating modes multiple waveforms should be used and multiple                such as signal processing, signal modulation, digital filtering, and curve fitting.
                                                                              www.keysight.com/find/MATLAB

1. As a reminder, the time differential between "send" and "receive" is
   related to the distance between the radar and the target.

                                                                          3
When measuring pulse waveforms that will be correlated for SLL          Once these preparations have been complete, the measurement
calculations, instrument calibration and waveform correction are        can be performed. Within the VSA software, the measured
other important factors. The reason: The wideband nature of most        frequency data (real and imaginary) is multiplied by the ideal
compressed pulses gives rise to potential inaccuracies in both          pulse. This result is processed with the inverse fast Fourier
phase and amplitude versus frequency within the measurement             transform (IFFT) function to produce the time cross correlation
instrument. To prevent these inaccuracies from affecting SLL            needed for the SLL measurement.
measurements, a measuring receiver with built-in equalization
and signal generation software or hardware with predistortion           Measured (t)  Ideal (t) = IFFT [Measured(f) * conj[Ideal(f)]]
capabilities is essential.                                                    Where
                                                                              Measured (f) = window * FFT (Measured (t))
Making time sidelobe measurements                                             Ideal (f) = window * FFT (Ideal (t))

The measurement process starts with detailed knowledge of the
ideal compressed pulse, as described above. The next requirement
is a suitable broadband signal analyzer, oscilloscope or logic
analyzer with vector signal analysis (VSA) software. Example
instruments include Keysight's PXA and MXA signal analyzers,
Infiniium 90000X-Series oscilloscopes and 16900 series logic
analyzers. These all support the Keysight 89600 VSA software,
which supports more than 70 signal formats and is capable of
implementing the mathematics needed to make and display the
time sidelobe measurement. The VSA software can run on a PC
or inside instruments such as those mentioned here.

The instrument is used to acquire and digitize the measured
waveform. The VSA software can be configured to use the                                                                                   



◦ Jabse Service Manual Search 2024 ◦ Jabse PravopisonTap.bg ◦ Other service manual resources online : FixyaeServiceinfo