Service Manuals, User Guides, Schematic Diagrams or docs for : Agilent 5991-2908EN Creating and Optimizing 802.11ac Signals with the M8190A AWG - Application Note c20140725 [9]

<< Back | Home

Most service manuals and schematics are PDF files, so You will need Adobre Acrobat Reader to view : Acrobat Download Some of the files are DjVu format. Readers and resources available here : DjVu Resources
For the compressed files, most common are zip and rar. Please, extract files with Your favorite compression software ( WinZip, WinRAR ... ) before viewing. If a document has multiple parts, You should download all, before extracting.
Good luck. Repair on Your own risk. Make sure You know what You are doing.




Image preview - the first page of the document
5991-2908EN Creating and Optimizing 802.11ac Signals with the M8190A AWG - Application Note c20140725 [9]


>> Download 5991-2908EN Creating and Optimizing 802.11ac Signals with the M8190A AWG - Application Note c20140725 [9] documenatation <<

Text preview - extract from the document
Keysight Technologies
Creating and Optimizing 802.11ac
Signals with the M8190A AWG




                 Application Note
Introduction

     The new IEEE 802.11ac wireless LAN standard aims to provide higher data throughput rates of over
     1 gigabit per second, to improve the user experience and to enable new applications, such as
     transmission of multiple streams of high-deinition multimedia data. To achieve these data rates, the
     Very High Throughput (VHT) physical layer speciication has introduced new features, including wider
     bandwidth channels of up to 160 MHz and 256 QAM modulation.

     802.11ac devices will need to meet more stringent speciications for RF performance, especially for
     error vector magnitude (EVM) over wider bandwidths, so it is important to have test tools that provide
     the best reference signals and EVM measurements, particularly for R&D and design validation.

     This application note details how to create and optimize 802.11ac signals using the N7617B Signal
     Studio for WLAN 802.11a/b/g/n/ac software with the Keysight Technologies, Inc. M8190A Arbitrary
     Waveform Generator (AWG) to get the highest quality signals from the instrument. This application
     note is based on the application note Creating and Optimizing 802.11ac Signals and Measurements,
     Literature number 5991-0574EN, which also includes the analysis of 802.11ac signals using the
     N9030A PXA signal analyzer and provides hints for achieving the best EVM measurements with this
     solution.
03 | Keysight | Creating and Optimizing 802.11ac Signals with the M8190A AWG 



◦ Jabse Service Manual Search 2024 ◦ Jabse PravopisonTap.bg ◦ Other service manual resources online : FixyaeServiceinfo