Service Manuals, User Guides, Schematic Diagrams or docs for : Agilent E5072A ENA Series Network Analyzer - Configuration Guide 5990-8001EN c20141209 [9]

<< Back | Home

Most service manuals and schematics are PDF files, so You will need Adobre Acrobat Reader to view : Acrobat Download Some of the files are DjVu format. Readers and resources available here : DjVu Resources
For the compressed files, most common are zip and rar. Please, extract files with Your favorite compression software ( WinZip, WinRAR ... ) before viewing. If a document has multiple parts, You should download all, before extracting.
Good luck. Repair on Your own risk. Make sure You know what You are doing.




Image preview - the first page of the document
E5072A ENA Series Network Analyzer - Configuration Guide 5990-8001EN c20141209 [9]


>> Download E5072A ENA Series Network Analyzer - Configuration Guide 5990-8001EN c20141209 [9] documenatation <<

Text preview - extract from the document
Keysight Technologies
E5072A ENA Series Network Analyzer
30 kHz to 4.5/8.5 GHz




                         Coniguration Guide
02 | Keysight | E5072A ENA Series Network Analyzer - Coniguration Guide



       Ordering Guide
       The following steps will guide you through configuring your E5072A. 1-year return to Keysight service warranty is included
       as standard

       Standard furnished item
        Description                                                Additional information
        Installation guide                                         Contains the information necessary to start up with the E5072A.
        Power Cable
        Calibration of Certiication
        IO LIBRARIES MEDIA SUITE


       Step 1. Choose test set option (Mandatory. Select one)
        Option no                                                  Description
        E5072A-245                                                 2-port, 30 kHz to 4.5 GHz, conigurable test set
        E5072A-285                                                 2-port, 30 kHz to 8.5 GHz, conigurable test set


       Step 2. Choose software option (Optional. If not required, go to step 3)
        Option no                                                  Description
        E5072A-008                                                 Frequency offset mode
        E5072A-010                                                 Time domain analysis


       Step 3. Choose time base option (Mandatory. Select one)
        Option no                                                  Description
        E5072A-UNQ                                                 Standard stability time base
        E5072A-1E5                                                 High stability time base


       Step 4. Choose hard disk drive option (Mandatory. Select one)
        Option no                                                  Description
        E5072A-017                                                 Removable hard disk drive
        E5072A-019                                                 Standard hard disk drive
03 | Keysight | E5072A ENA Series Network Analyzer - Coniguration Guide



       Step 5. Choose accessory option (Optional. If not required, go to step 6)
        Option no                                                  Description
        E5072A-1CM                                                 Rack mount kit
        E5072A-1CN                                                 Front handle kit
        E5072A-1CP                                                 Rack mount and Front handle kit
        E5072A-810                                                 Add keyboard
        E5072A-820                                                 Add mouse


       Step 6. Choose calibration option (Optional. If not required, go to step 7)
        Option no                                                  Description
        E5072A-1A7                                                 ISO 17025 compliant calibration
        E5072A-A6J                                                 ANSI Z540 compliant calibration


       Step 7. Choose warranty service (Optional)
        Option no                                                  Description
        R-50C-011-3                                                3 year return-to Keysight warranty and service
        R-50C-011-5                                                5 year return-to Keysight warranty and service
04 | Keysight | E5072A ENA Series Network Analyzer - Coniguration Guide



       Test Accessories and Calibration Kits
       Test accessories and calibration kits that can be used with the E5072A are listed in this section. A complete line of test
       accessories and calibration kits can be found at the Keysight RF and Microwave Test Accessories Web site:
       www.keysight.com/find/accessories


       Test accessories
       Test accessories such as test port cable are necessary for a complete measurement system using the E5072A. Order test
       accessories in accordance with the desired measurement system.


       Calibration kits
       Calibration is an accuracy enhancement procedure that effectively reduces the system errors that cause uncertainty in
       network measurement. Calibration kit is necessary to perform the calibration.

         



◦ Jabse Service Manual Search 2024 ◦ Jabse PravopisonTap.bg ◦ Other service manual resources online : FixyaeServiceinfo