Quick Start Guide
                    Agilent Technologies
                    14565A Device
                    Characterization Software
                    for Windows 95,
                    Windows 98, and
                    Windows NT 4.0
Contents

Description ...........................................................................................................3

System Requirements ...........................................................................................3

Installing and Running the Software.....................................................................4

Configuring the I/O ..............................................................................................4

Performing Basic Operations................................................................................5

Display Area.........................................................................................................6

Making Triggered Measurements.........................................................................7

Performing Measurements on Waveforms............................................................8

Placing a Waveform on the Display .....................................................................9

Printing and Saving Measurement Data..............................................................10

Advanced Measurement Settings........................................................................10

Display Preferences ............................................................................................10

Source Settings ...................................................................................................11

Sample Waveforms.............................................................................................11

Warranty.............................................................................................................12




                                                          2
Description
What the          The Agilent Technologies 14565A Device Characterization
Agilent           Software is an easy-to-use graphical user interface for the
14565A            Agilent 66300-series Dynamic Measurement DC Sources. With
Will Do           it, you can:
                  a Control output and measurement functions from a single
                        screen.
                  a View an oscilloscope-like display of dynamic output
                        measurements.
                  a Superimpose up to two stored waveforms on active
                        waveform data.
                  a Get measurement details by zooming in on active
                        waveforms.
                  a View calculated measurements based on active waveforms.
                  a Save and recall waveform data.
What the          The Agilent 14565A Device Characterization Software does not:
Agilent           a Control instruments other than Agilent dc sources.
14565A
                  a Provide drivers for other GPIB instruments.
Will Not Do
                  a Operate with Windows 3.1.



System Requirements
PC            a 486DX66 (minimum)
              a 16 Mbytes RAM
              a 4 Mbytes of disk space
32-bit        a Windows 98
Platforms     a Windows 95
              a Windows NT 4.0
Supported     a Agilent 82340B, 82341C, 82341D, 82335B1
I/O           a National AT GPIB/TNT, AT GP-IB/TNT PnP (Windows 95)
              a RS-232
              1
               The Agilent 82335B is only supported for Windows 95, provided you have
              either the E2094F or E2094E I/O library.

Supported     a Agilent 66309B/D
Dc Source     a Agilent 66311A/B/D
Models        a Agilent 66312A/66332A
              a Agilent 66319B/D; 66321B/D




                                         3
   Installing and Running the Software

   NOTE: Before running the Agilent 14565A application, you must have installed
         and connected your dc source to the PC using the appropriate interface
         cable. You must also have the appropriate interface card installed and
         configured. If you are using an Agilent interface card, you must have
         the appropriate 32-bit SICL or VISA library drivers installed.

   1.    Place Disk #1 in the A: drive of your computer and run SETUP.EXE.
   2.    Follow the directions on the screen to install the software. The
         README.TXT file contains product updates or corrections that are not
         documented in the help file. Use any text editor to open and read this file.
   3.    To run the Agilent 14565A application, click on its desktop icon.
         You can also click on the Start button and select:
         Programs | Agilent 4565A DCS | Agilent 14565A DCS

   Configuring the I/O
   Make sure that the dc source is turned on. To configure the I/O, select the I/O
   Configuration command in the Edit menu. This step is necessary to establish
   communication with the dc source. The I/O configuration screen comes up
   automatically when you turn Simulation mode off in the Source menu.
   Note that the serial port is much slower than the HP-IB interface.
  Select I/O type.                                                         Serial port only.
    (HPIB, GPIB,                                                           Specifies the comm
  VISA, or serial)                                                         port on the PC.

   Address must                                                            Serial port only. Dc
 match setting of                                                          source must match
     instrument.                                                           these Baud rate,
(HPIB/GPIB only)                                                           Parity and Flow
                                                                           control settings
 For HPIB cards
only. Must match                                                           Click to automatically
SICL name used                                                             search for any dc
  in GPIB card's                                                           source on the
   configuration.                                                          interface.



   If there seems to be no communication between the Agilent 14565A application
   and the dc source, select Auto Detect to detect any dc sources connected to your
   pc. Also, try resetting the I/O interface by clicking the red reset button. This also
   resets the dc source to its default settings.

NOTE:          If you program the Agilent dc source from the front panel of the unit,
               you will need to refresh or update the Agilent 14565A application. Go
               to the View menu and select the Reread Instrument State command.




                                             4
        Performing Basic Operations
        The Main window appears when you run the Agilent 14565A application. From
        this window you can control the output of the dc source and view output
        measurements.

        NOTE:        Not all controls are displayed when you initially run the Agilent
                     14565A application. Output 2 controls are only available on Agilent
                     66309B/D and 66319B/D. DVM controls are only available on
                     Agilent 66311D/66309D and 66319D/66321D.

                                                                                  Click V to
                                                                                  measure voltage;
                                                                                  Click A to
        Turn on                                                                   measure current.
       output 1.

  Enter voltage                                                                   Click to make a
    and current                                                                   measurement.
   for output 1.                                                                  This overwrites
                                                                                  the previous
                                                                                  waveform.
  Output 2 and
  DVM controls
   not available                                                                  Adjust values to
 on all models.                                                                   vary sample rate
Use View menu                                                                     and vertical scale.
     to display.                                                                  Can be done
                                                                                  before or after
                                                                                  measurement.




        To display a sample waveform:
        a     Select the Load Waveform command in the File menu, and then select
              DemoWaveform1.txt.
        a     Select Active Waveform in the Load Waveform Location dialog box. The
              waveform should match the one shown in the above figure.
        To set the voltage, current, and resistance levels:
        a     Click in the field labeled Voltage, type in the desired output voltage and
              press Enter.
        a     Enter a current limit value in the field labeled Current.
        a     For units that have programmable output resistance, enter a resistance value
              in the field labeled Resistance.
        To turn on the output:
        a     Enable the dc source output by pressing the ON button. On some models,
              each output has its own output control. If the message OVLD appears in
              the display, set the Current Measurement control to the Hi Range.


                                                  5
  To make a measurement:
  a     Click the A button to select current measurements; click the V button to
        select voltage measurements.
  a     Click the Measure button to make the measurement.
  a     Adjust the time/div and amps/div fields to adjust the sample rate and vertical
        scale. Click Auto Scale to fit the display to the acquired waveform.
  To view the output 2 controls and the DVM display:
  a     If your dc source has a second output or a DVM input, go to the View menu
        and check the item that you wish to display.
         Second Output
         Digital Voltmeter
        If the item is greyed out, your dc source does not have this feature.

  Display Area
  The display area displays the output measurement after the Measure button is
  pressed. Only measurements from the main output can be displayed. The
  following figure describes the various measurements displayed in the window.

      Maximum
      measured
         value.

   Vertical axis                                                             Average high
       displays                                                              level.
    amplitude.



      Minimum
      measured                                                               Average low
         value.                                                              level.


   Displays the
measurements
calculated from
 the waveform.




  The values in the measurement area at the bottom of the display are calculated
  from the all of the data that is captured in the display. If horizontal markers have
  been set, measurements are calculated only from the data between the markers.
  Refer to Performing Measurements on Waveforms.
  Calculated measurements at the bottom of the display may not agree exactly with
  values shown on the front panel of the instrument if the sample rate of the
  display differs significantly from the instrument's front panel sample rate.


                                           6
    Making Triggered Measurements

    Triggered measurements let you control when the measurement trigger will
    occur. The following figure describes the various trigger controls.

    NOTE:          If you do not know where to set the trigger level, you can make a
                   measurement with the trigger set to Auto Trig. Then view the
                   measurement to see where to place the trigger level. Set the trigger
                   controls and make another measurement.



                                                                                   Click to
                                                                                   initialize a
                                                                                   triggered
 Move slide to                                                                     measurement
    specify the
  trigger level.
                                                                                   Trigger level
                                                                                   is identified by
   Set up the                                                                      a red line.
    triggered
measurement                                                                        Trigger offset
                                                                                   is identified by
 Move slide to                                                                     a vertical red
      specify a                                                                    line.
 trigger offset.

                                                                                   Specifies a
   Specify # of                                                                    hysteresis band
sweeps. Refer                                                                      around the
to online help.                                                                    trigger level.




    a      Click the A button to select current measurements; click the V button to
           select voltage measurements.
    