Agilent 16192A
Parallel Electrode SMD Test Fixture
Operation and Service Manual
Agilent 16192A Parallel Electrode SMD Test Fixture
Operation and Service Manual




               Agilent Part No. 16192-90030
              Printed in JAPAN August 2001
                      Sixth Edition
Notice
The information contained in this document is subject to change without notice.
This document contains proprietary information that is protected by copyright. All rights are
reserved. No part of this document may be photocopied, reproduced, or translated to another
language without the prior written consent of the Agilent Technologies.

  Agilent Technologies Japan, Ltd.
  Component Test PGU-Kobe
  1-3-2, Murotani, Nishi-ku, Kobe-shi,
  Hyogo, 651-2241 Japan





 Copyright Agilent Technologies Japan, Ltd. 1993, 1996, 1999, 2000, 2001
c
Manual Printing History
The manual printing date and part number indicate its current edition. The printing date
changes when a new edition is printed. (Minor corrections and updates that are incorporated
at reprint do not cause the date to change.) The manual part number changes when extensive
technical changes are incorporated.
   December 1993 : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : First Edition
   June 1996 : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : Second Edition
   October 1996 : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : Third Edition (part number: 16192-90010)
   December 1999 : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : Fourth Edition (part number: 16192-90010)
   September 2000 : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : Fifth Edition (part number: 16192-90020)
   August 2001 : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : Sixth Edition (part number: 16192-90030)




                                                                                                                                                                        iii
Safety Summary
The following general safety precautions must be observed during all phases of operation,
service, and repair of this instrument. Failure to comply with these precautions or with specic
WARNINGS given elsewhere in this manual violates safety standards of design, manufacture,
and intended use of the instrument.
The Agilent Technologies assumes no liability for the customer's failure to comply with these
requirements.

DO NOT Operate In An Explosive Atmosphere
Do not operate the instrument in the presence of 
ammable gasses or fumes. Operation of any
electrical instrument in such an environment constitutes a safety hazard.

Keep Away From Live Circuits
Operating personnel must not remove instrument covers. Component replacement and internal
adjustments must be made by qualied maintenance personnel. Do not replace components
with the power cable connected. Under certain conditions, dangerous voltages may exist even
with the power cable removed. To avoid injuries, always disconnect power and discharge
circuits before touching them.

DO NOT Service Or Adjust Alone
Do not attempt internal service or adjustment unless another person, capable of rendering rst
aid and resuscitation, is present.

DO NOT Substitute Parts Or Modify Instrument
Because of the danger of introducing additional hazards, do not substitute parts or perform
unauthorized modications to the instrument. Return the instrument to a Agilent Technologies
Sales and Service Oce for service and repair to ensure the safety features are maintained.

Dangerous Procedure Warnings
Warnings, such as the example below, precede potentially dangerous procedures throughout
this manual. Instructions contained in the warnings must be followed.
Warning         Dangerous voltages, capable of causing death, are present in this
                instrument. Use extreme caution when handling, testing, and adjusting
                this instrument.

The voltage levels found in this test xture when used with the intended instruments do not
warrant more than normal safety precautions for operator safety.




iv
Operating Precaution
Do not exceed the operating input power, voltage, and current level and signal type
appropriate for the instrument being used, refer to your instrument's operation manual.

Caution         Electrostatic discharge (esd) can damage the highly sensitive microcircuits in
                your instrument. ESD damage is most likely to occur as the test xtures are
                being connected or disconnected. Protect them from ESD damage by wearing a
                grounding strap that provides a high resistance path to ground. Alternatively,
                ground yourself to discharge any static charge built-up by touching the
                outer shell of any grounded instrument chassis before touching the test port
                connectors.
                Never touch the test clip contacts.
                Use a work station equipped with an anti-static work surface.




Certication
Agilent Technologies certies that this product met its published specications at the time
of shipment from the factory. Agilent Technologies further certies that its calibration
measurements are traceable to the United States National Institute of Standards and
Technology, to the extent allowed by the Institution's calibration facility, or to the calibration
facilities of other International Standards Organization members.



Warranty
This Agilent Technologies instrument product is warranted against defects in material and
workmanship for a period of one year from the date of shipment, except that in the case of
certain components listed in Instrument Specications of this manual, the warranty shall be
for the specied period. During the warranty period, Agilent Technologies will, at its option,
either repair or replace products which prove to be defective.
For warranty service or repair, this product must be returned to a service facility designated by
Agilent Technologies. Buyer shall prepay shipping charges to Agilent Technologies and Agilent
Technologies shall pay shipping charges to return the product to Buyer. However, Buyer shall
pay all shipping charges, duties, and taxes for products returned to Agilent Technologies from
another country.
Agilent Technologies warrants that its software and rmware designated by Agilent
Technologies for use with an instrument will execute its programming instruction when
property installed on that instrument. Agilent Technologies does not warrant that the operation
of the instrument, or software, or rmware will be uninterrupted or error free.




                                                                                                     v
Limitation Of Warranty
The foregoing warranty shall not apply to defects resulting from improper or inadequate
maintenance by Buyer, Buyer-supplied software or interfacing, unauthorized modication or
misuse, operation outside of the environmental specications for the product, or improper site
preparation or maintenance.
No other warranty is expressed or implied. Agilent Technologies specically disclaims the
implied warranties of merchantability and tness for a particular purpose.



Exclusive Remedies
The remedies provided herein are buyer's sole and exclusive remedies. Agilent Technologies
shall not be liable for any direct, indirect, special, incidental, or consequential damages,
whether based on contract, tort, or any other legal theory.



Assistance
Product maintenance agreements and other customer assistance agreements are available for
Agilent Technologies products.
For any assistance, contact your nearest Agilent Technologies Sales and Service Oce.
Addresses are provided at the back of this manual.




vi
Safety Symbols
General denitions of safety symbols used on equipment or in manuals.
                Instruction manual symbol: the product is marked with this symbol when it is
                necessary for the user to refer to the instruction manual in order to protect
                against damage to the instrument.
                Indicates dangerous voltage (terminals fed from the interior by voltage
                exceeding 1000 volts must be so marked).
                Protective conductor terminal. For protection against electrical shock in case
                of a fault. Used with wiring terminals to indicate the terminal which must be
                connected to ground before operating equipment.
                Low-noise or noiseless, clean ground (earth) terminal. Used for a signal
                common, as well as providing protection against electrical shock in case of
                fault. A terminal marked with this symbol must be connected to ground in the
                manner described in the installation (Operation) manual, and before operating
                the equipment.
                Frame or chassis terminal. A connection to the frame (chassis) of the
                equipment which normally includes all exposed metal structures.
                Alternating current (power line).
                Direct current (power line).
                Alternating or direct current (power line).
                Warning denotes a hazard.     It calls attention to a procedure, practice, condition
                or the like, which, if not correctly performed or adhered to, could result in
                injury or death to personnel.
                Caution sign denotes a hazard. It calls attention to a procedure, practice,
                condition or the like, which, if not correctly performed or adhered to, could
                result damage to or destruction of part or all of the product.
                Note denotes important information. It calls attention to a procedure, practice,
                condition or the like, which is essential to highlight.




                                                                                                  vii
APC-7
 is a U.S. registered trademark of the Bunker Ramo Corporation.
     R

viii
Contents
 1. General Information
    Introduction . . . . . . . . . . . . . . .    .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .     1-1
      Manual Summary . . . . . . . . . . .        .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .     1-1
    Product Description . . . . . . . . . . .     .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .     1-1
    Applicable Instruments . . . . . . . . . .    .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .     1-1
    Options Available . . . . . . . . . . . .     .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .     1-2
    Accessories Supplied . . . . . . . . . . .    .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .     1-2
    Specications . . . . . . . . . . . . . .     .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .     1-2
    Supplemental Performance Characteristics      .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .     1-3
    Residual Inductance of the Shorting Bar . .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .     1-4
 2. Preparation for Use
    Introduction . . . . . . . . . . . . . . . . . . . . . . .                    .   .   .   .   .   .   .   .   .   .     2-1
    Initial Inspection . . . . . . . . . . . . . . . . . . . . .                  .   .   .   .   .   .   .   .   .   .     2-1
    Adjusting the Conguration to SMD Size . . . . . . . . . .                    .   .   .   .   .   .   .   .   .   .     2-3
    Connecting the Test Fixture for Use . . . . . . . . . . . .                   .   .   .   .   .   .   .   .   .   .     2-4
    Repackaging the Test Fixture For Shipment . . . . . . . .                     .   .   .   .   .   .   .   .   .   .     2-5
    Measurement Error Correcting Function for Each Instrument                     .   .   .   .   .   .   .   .   .   .     2-6
 3. Operation
    Introduction . . . . . . . . . . . . . . . . . . . . . .                  .   .   .   .   .   .   .   .   .   .   .     3-1
    Operating Flow . . . . . . . . . . . . . . . . . . . .                    .   .   .   .   .   .   .   .   .   .   .     3-1
    Overview . . . . . . . . . . . . . . . . . . . . . . .                    .   .   .   .   .   .   .   .   .   .   .     3-2
    How to set the SHORT condition, and the OPEN condition                    .   .   .   .   .   .   .   .   .   .   .     3-3
      Setting the SHORT condition . . . . . . . . . . . . .                   .   .   .   .   .   .   .   .   .   .   .     3-3
      Setting the OPEN condition . . . . . . . . . . . . .                    .   .   .   .   .   .   .   .   .   .   .     3-4
    How to connect the DUT . . . . . . . . . . . . . . . .                    .   .   .   .   .   .   .   .   .   .   .     3-5
 4. Service
    Introduction . . . . . . . . . . . . . . . . . .          .   .   .   .   .   .   .   .   .   .   .   .   .   .   .    4-1
    General Information . . . . . . . . . . . . . .           .   .   .   .   .   .   .   .   .   .   .   .   .   .   .    4-1
    Assembly Replacement . . . . . . . . . . . . .            .   .   .   .   .   .   .   .   .   .   .   .   .   .   .    4-3
      Disassembly and Assembly Procedure . . . . .            .   .   .   .   .   .   .   .   .   .   .   .   .   .   .    4-3
        Length Positioning Stage Assembly Removal:            .   .   .   .   .   .   .   .   .   .   .   .   .   .   .    4-3
        Width Positioning Stage Assembly Removal: .           .   .   .   .   .   .   .   .   .   .   .   .   .   .   .    4-3
      Replaceable Parts . . . . . . . . . . . . . .           .   .   .   .   .   .   .   .   .   .   .   .   .   .   .    4-4
    Troubleshooting . . . . . . . . . . . . . . . .           .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   4-10
      Open Impedance Check . . . . . . . . . . .              .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   4-10
      Short Impedance Check . . . . . . . . . . .             .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   4-11
      Short Impedance Repeatability Check . . . . .           .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   4-11




                                                                                                                      Contents-1
Figures
    1-1.   Applicable DUT Size . . . . . . . . . . . . . . . . . . . .     .   .   .   .   .   .   .   .    1-3
    1-2.   Simulation Setup . . . . . . . . . . . . . . . . . . . . .      .   .   .   .   .   .   .   .    1-5
    2-1.   16192A Product Overview . . . . . . . . . . . . . . . . .       .   .   .   .   .   .   .   .    2-2
    2-2.   Electrodes conguration and SMD Size . . . . . . . . . . .      .   .   .   .   .   .   .   .    2-3
    2-3.   Connecting the Test Fixture with APC-7
 Connector (4291B)
                                                    R                      .   .   .   .   .   .   .   .    2-4
    3-1.   16192A Test Fixture Overview . . . . . . . . . . . . . . .      .   .   .   .   .   .   .   .    3-2
    4-1.   16192A Product Overview . . . . . . . . . . . . . . . . .       .   .   .   .   .   .   .   .    4-2
    4-2.   Replaceable Parts for Main Assembly . . . . . . . . . . . .     .   .   .   .   .   .   .   .    4-4
    4-3.   Replaceable Parts for Length Positioning Stage Assembly . . .   .   .   .   .   .   .   .   .    4-5
    4-4.   Replaceable Parts for Insertion Clip Assembly . . . . . . . .   .   .   .   .   .   .   .   .    4-6
    4-5.   Replaceable Parts for Width Positioning Stage Assembly . . .    .   .   .   .   .   .   .   .    4-7
    4-6.   Replaceable Parts for Test Stage Assembly . . . . . . . . . .   .   .   .   .   .   .   .   .    4-8
    4-7.   Obsolete parts manufactured earlier than 1996 . . . . . . .     .   .   .   .   .   .   .   .    4-9
    4-8.   Shorting Device Position . . . . . . . . . . . . . . . . . .    .   .   .   .   .   .   .   .   4-10




Tables
    1-1.   Furnished Accessories . . . . . . . . . . . . . . . . . . .     .   .   .   .   .   .   .   .    1-2
    1-2.   Supplied Shorting Device Residual Inductance (Typical) . . .    .   .   .   .   .   .   .   .    1-4
    1-3.   Option 010 Shorting Device Residual Inductance (Typical) . .    .   .   .   .   .   .   .   .    1-4
    2-1.   16192A Contents . . . . . . . . . . . . . . . . . . . . .       .   .   .   .   .   .   .   .    2-2
    2-2.   Measurement Error Correcting Functions for Each Instrument      .   .   .   .   .   .   .   .    2-6
    4-1.   16192A Product Overview . . . . . . . . . . . . . . . . .       .   .   .   .   .   .   .   .    4-2
    4-2.   Replaceable Parts for Main Assembly . . . . . . . . . . . .     .   .   .   .   .   .   .   .    4-4
    4-3.   Replaceable Parts for Length Positioning Stage Assembly . . .   .   .   .   .   .   .   .   .    4-5
    4-4.   Replaceable Parts for Insertion Clip Assembly . . . . . . . .   .   .   .   .   .   .   .   .    4-6
    4-5.   Replaceable Parts for Width Positioning Stage Assembly . . .    .   .   .   .   .   .   .   .    4-7
    4-6.   Replaceable Parts for Test Stage Assembly . . . . . . . . . .   .   .   .   .   .   .   .   .    4-9
    4-7.   Open Impedance Value Guideline . . . . . . . . . . . . . .      .   .   .   .   .   .   .   .   4-11
    4-8.   Short Impedance Value Guideline . . . . . . . . . . . . . .     .   .   .   .   .   .   .   .   4-11
    4-9.   Short Impedance Repeatability Guideline . . . . . . . . . .     .   .   .   .   .   .   .   .   4-11




Contents-2
                                                                                                                 1
General Information
Introduction
The purpose of this manual is to enable you to use your 16192A Parallel Electrode SMD Test
Fixture eciently and condently.

Manual Summary
This manual contains the following:
  The specications of the 16192A (see this chapter).
  Installing the 16192A (see Chapter 2).
  Operating the 16192A (see Chapter 3).
  Ordering replaceable parts for the 16192A (see Chapter 4).



Product Description
The 16192A is used to measure a parallel electrodes surface mount device (SMD) with high
repeatability.



Applicable Instruments
The 16192A has been designed to operate specically with the following LCR meters and
impedance analyzers:
  You can directly connect the 16192A to:                                  4191A, 4291B, E4991A
  You can use the 16192A with 43961A:                                      4395A (option 010),
                                                                           4396A/B (option 010)
  You can use the 16192A with 41951A:                                      4195A
  You can use the 16192A with RF adapter 42942A:                           4294A
  You can use the 16192A with RF adapter 16085B:                           4284A1
  You can use the 16192A with RF adapter 16099A:                           4194A with 41941A23
  1 The 4284A is a typical instrument. Other 4-terminal pair instruments that can be used with the 16085B are
    also applicable.
  2 The 4194A with 41941A is a typical instrument. Other instruments that can be used with the 16099A are also
    applicable.
  3 The 16192A is not adapted by some old type 16099A. For detail, please contact your Agilent Technologies sales
    oce.




                                                                                           General Information      1-1
Options Available
The following option is supplied for the 16192A:
Option 001      Delete the magnifying lens and tweezers
Option 010      Add industry standard size short bar set



Accessories Supplied
The following accessories are supplied with the 16192A:
                                                   Table 1-1. Furnished Accessories
                                             Description             Part Number                                                       Quantity
                        Operation and Service Manual                                         P/N 16192-90030                                   1
                        Shorting device (4 types)                                            P/N 16191-29001                                   1
                                                                                             P/N 16191-29002                                   1
                                                                                             P/N 16191-29003                                   1
                                                                                             P/N 16191-29004                                   1
                        Case for shorting devices                                            P/N 1540-0692                                     1
                        Option 010*1                                                         P/N 16191-29005                                   1
                                                                                             P/N 16191-29006                                   1
                                                                                             P/N 16191-29007                                   1
                                                                                             P/N 16191-29008                                   1
                        Magnifying lens                                                      P/N 16193-60002                                   1
                        Tweezers                                                             P/N 8710-2081                                     1
                        Insulator                                                            P/N 16192-09002                                   1

*1 Option 010 sizes are the same as industry standard (EIA/EIAJ) SMD sizes. This short bar
set has the following SMD sizes included : 1005(mm)/0402(inch), 1608(mm)/0603(inch),
2012(mm)/0805(inch), 3216(mm)/1206(inch). Order option 010 if the SMD that is to be measured
has the same size as the EIA/EIAJ sizes.



Specications
This section lists the complete 16192A specications. These specications are the performance
standards and limits against which the 16192A is tested. When shipped from the factory, the
16192A meets the following specications:
   Maximum DC Bias Voltage : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : 6 40V
   Operating Temperature : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : 055 to +85 C
   Operating Humidity (@wet bulb temperature <40 C)
       : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : 15 % to 95 % RH
   Non-operating Temperature : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : 055 to +85 C
   Non-operating Humidity (@wet bulb temperature <65 C)
      : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : Up to 90 % RH
   Weight : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : 400 g
   Dimension : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : 150(W) 2 70(H) 2 90(D) [mm]


1-2     General Information
Supplemental Performance Characteristics
This section lists supplemental performance characteristics. Supplemental performance
characteristics are not specications, but are typical characteristics included as additional
information for the operator. Supplemental performance characteristics are not guaranteed.
   Frequency Range : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : DC to 2 GHz
   Applicable DUT size (see Figure 1-1) : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : 1 mm to 20 mm
   Supplied shorting device size
       P/N 16191-29001                   : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : 1 2 1 2 2.4 [mm]
       P/N 16191-29002                   : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : 1.6 2 2.4 2 2 [mm]
       P/N 16191-29003                   : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : 2.4 2 2.4 2 3.2 [mm]
       P/N 16191-29004                   : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : 2.4 2 2.4 2 4.5 [mm]
   Option 010 shorting device size
     P/N 16191-29005 : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : 1.0(L) 2 0.5(W) 2 0.5(H) [mm]
     P/N 16191-29006 : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : 1.6(L) 2 0.8(W) 2 0.8(H) [mm]
     P/N 16191-29007 : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : 2.0(L) 2 1.2(W) 2 0.8(H) [mm]
     P/N 16191-29008 : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : 3.2(L) 2 1.6(W) 2 0.8(H) [mm]
   Electrical length (when the length between electrodes is 2 mm) : : : : : : : : : : : : : : : : : : : : : : : 11 mm
   Additional Error3 : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : 1.5 2 f2 [%]
   Repeatability3
       (for inductive component) : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : 30 + 250 2 f [m
]
                                                                                                                                           (impedance of 30 m
, 40 pH)
        : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : 2 + 30 2 f [S]
                                                                                                                                                  (admittance of 2 S, 5 fF)
      3 f: frequency (GHz)




                                                         Figure 1-1. Applicable DUT Size




                                                                                                                                              General Information                1-3
Residual Inductance of the Shorting Bar
The usual method to compensate the test xture's residual inductance is to let SHORT = 0H.
In this method, the measurement result is the relative value of the measured impedance to the
shorting bar's impedance. The short bar's residual inductance as a result of its size and shape is
not estimated.
On the other hand, there is a denition method to let SHORT = x H. In this method, the
measurement result is the absolute value of the device's impedance. The short bar's residual
inductance as a result of its size and shape is estimated under specic conditions and is used as
a reference value. This method, is useful for devices with values which are close to the short
conditions of the measurement system.
The reference inductance values presented Table 1-2 and Table 1-3 were simulated as the
relative dierence to a disk-type 0 
 termination on either the 7 mm or the 3.5 mm connector.
The measurement of these short bars under other conditions than shown below cannot
reproduce the reference inductance values.
             Table 1-2. Supplied Shorting Device Residual Inductance (Typical)
         Shorting Bar l [mm] d [mm] h [mm] Oset [mm] Connector Inductance
                                                                         (Typical)
       P/N 16191-29001        1      2.4        1          0.75     3.5 mm           0.2 nH
       P/N 16191-29002      1.6      2.4        2          0.45     3.5 mm           0.2 nH
       P/N 16191-29002        2      2.4      1.6          0.25     3.5 mm           0.2 nH
       P/N 16191-29002      2.4        2      1.6           1.3       7 mm           0.7 nH
       P/N 16191-29003      3.2      2.4      2.4           0.9       7 mm           0.6 nH
       P/N 16191-29004      4.5      2.4      2.4             0       7 mm           0.6 nH

            Table 1-3. Option 010 Shorting Device Residual Inductance (Typical)
         Shorting Bar l [mm] d [mm] h [mm] Oset [mm] Connector Inductance
                                                                         (Typical)
       P/N 16191-29005      1.0      0.5      0.5          0.75     3.5 mm           0.5 nH
       P/N 16191-29006      1.6      0.8      0.8          0.45     3.5 mm           0.4 nH
       P/N 16191-29007      2.0      1.2      0.8           1.5       7 mm           0.9 nH
       P/N 16191-29008      3.2      1.6      0.8           0.9       7 mm           0.8 nH




1-4   General Information
Figure 1-2. Simulation Setup




                               General Information   1-5
                                                                                                  2
Preparation for Use
Introduction
This chapter explains how to install the 16192A. The topics include the following:
  Initial inspection.
  Connecting the test xture for use.
  Repackaging the test xture for shipment.
  Measurement error correcting function for each instrument.



Initial Inspection
The parallel electrode SMD test xture has been carefully inspected before being shipped
from the factory. It should be in perfect physical condition, no scratches, dents or the like. It
should also be in perfect electrical condition. Verify this by carefully performing an incoming
inspection to check the parallel electrode SMD test xture set for signs of physical damage and
missing contents. If any discrepancy is found, notify the carrier and Agilent Technologies. Your
Agilent Technologies sales oce will arrange for repair and replacement without waiting for
the claim to be settled.
  Inspect the shipping container for damage. Keep the shipping materials until the inspection is
  completed.
  Verify that the shipping container contains everything shown in Figure 2-1 and listed in
  Table 2-1.
  Inspect the exterior of the 16192A for any signs of damage.




                                                                            Preparation for Use   2-1
                                  Figure 2-1. 16192A Product Overview
                                     Table 2-1. 16192A Contents
                            Description                  Agilent Part                       Quantity
                                                            Number
          
 Test xture
          1                                                       16192A                            1
          
 Operation and Service Manual1
          2                                                       P/N 16192-90030                   1
          
 Shorting device2 (12122.4[mm])
          3                                                       P/N 16191-29001                   1
                              (1.622.422[mm])                     P/N 16191-29002                   1
                              (2.422.423.2[mm])                   P/N 16191-29003                   1
                              (2.422.424.5[mm])                   P/N 16191-29004                   1
          
 Case for shorting device
          4                                                       P/N 1540-0692                     1
          
 Magnifying lens34
          5                                                       P/N 16193-60002                   1
          
 Tweezers4
          6                                                       P/N 8710-2081                     1
          
 Insulator
          7                                                       P/N 16192-09002                   1

          1 Operation and Service Manual is not shown in Figure 2-1.
          2 Depending on your order conguration.
          3 The magnifying lens is packed separately from the 16192A body. Connect it as shown in
            Figure 2-1.
          4 Not contained if you ordered the 16192A option 001.



2-2   Preparation for Use
Adjusting the Conguration to SMD Size
The 16192A's applicable SMD size is 1 mm to 20 mm, changing the electrodes conguration as
follows.




                    Figure 2-2. Electrodes conguration and SMD Size

                                                                         Preparation for Use   2-3
Connecting the Test Fixture for Use
Note      Some instruments require an adapter to be connected to the 16192A (see
                    \Applicable Instruments" in Chapter 1).


1. Calibrate your analyzer at the APC-7
 connector plane before connecting test xture. See
                                          R
   Table 2-2 for the applicable error correcting function. After calibration, disconnect any
   standards from the APC-7
 connector.
                              R

2. Place the xture on the APC-7
 connector.
                                   R

3. Tighten (turn counterclockwise) the coupling nut of the APC-7
 connector.
                                                                   R




           Figure 2-3. Connecting the Test Fixture with APC-7
 Connector (4291B)
                                                             R




2-4   Preparation for Use
Repackaging the Test Fixture For Shipment
If shipment to an Agilent Technologies service center is required, each test xture should be
repackaged using the original factory packaging materials.
If this material is not available, comparable packaging materials may be used. Wrap the parallel
electrode SMD test xture in heavy paper and pack in anti-static plastic packing material. Use
sucient shock absorbing material on all sides of the 16192A to provide a thick, rm cushion
and to prevent movement. Seal the shipping container securely and mark it FRAGILE.




                                                                            Preparation for Use   2-5
    Measurement Error Correcting Function for Each Instrument
    Each LCR meter or analyzer has measurement error correcting functions. Table 2-2 shows the
    functions of the instrument that can be used for calibration, setting the electrical length, and
    Open/Short/Load compensation.
             Table 2-2. Measurement Error Correcting Functions for Each Instrument
  Instrument          Calibration        Electrical length         OPEN             SHORT            LOAD
                                                                Compensation     Compensation     Compensation
4291A                Calibration       Selecting Test Fixture       OPEN             SHORT           LOAD
                        OPEN              Port Extension         Compensation     Compensation    Compensation1
                       SHORT
                        LOAD
                 LOW-LOSS Capacitor1
4191A                Calibration         Electrical Length       No capability    No capability    No capability
                          0S
                          0

                         50 

4194A with          No capability          No capability        OPEN Correction SHORT Correction LOAD Correction1
16085B
4195A with          Calibration OPEN       Port Extension         0 S OFFSET       0 
 OFFSET      No capability
41951A                   SHORT            (Port 1 or Port 2)
                          LOAD
4194A with             Calibration         No capability         Compensation     Compensation     No capability
41941A/B,                   0S                                    ZERO OPEN       ZERO SHORT
16099A                      0

                           50 

4194A with             Calibration         No capability         Compensation     Compensation     No capability
16085B                      0S                                    ZERO OPEN       ZERO SHORT
                            0

                           50 


1 According to demand for precise measurement




    2-6   Preparation for Use
                                                                                                                 3
Operation
Introduction
This chapter describes how to use the test xture and the measurement error correcting
techniques for the test xture.

Operating Flow
Before performing a measurement, you have to compensate for the residual error of the test
xture by using the measurement error correcting functions. Perform the following steps when
measuring the DUT:
   The 16192A has inherent stray capacitance, residual inductance, and residual resistance that aect the
   measurement. To compensate for these residuals and thus minimize their eect on measurement accuracy, the
   measurement instrument's OPEN and SHORT compensation capabilities must be used.

                                              ( 7 indicates procedures in the following pages.)

                                  Described in Chapter 2.



                                  The 16192A's electrical length is 11 mm (typical value).
                                  To set the electrical length, see your analyzer's Operation Manual.


                                  To set the xture and devices for xture compensation, see:
                                  7 \How to set the SHORT condition, and the OPEN condition"
                                  These procedures show how to set the test xture for the
                                  OPEN/SHORT/LOAD compensation procedure.
                                  For how to measure OPEN/SHORT/LOAD, see the Operation Manual
                                  supplied with your analyzer. (You can omit LOAD compensation.)


                                  To connect the DUT, see:
                                  7 \How to connect the DUT"




 3 The compensating functions are dierent for each instrument. See Table 2-2 and perform the listed functions.


                                                                                                     Operation   3-1
Overview




                       Figure 3-1. 16192A Test Fixture Overview
Length positioning stage Slides to x an electrode.
Length locking knob        Fixes the length positioning stage.
Device stage               Te
on sheet to place the device.
Device holder              Fixes a device.
Width locking knob         Fixes the width positioning stage.
Width positioning stage Fixes the device holder and the device stage.
Device holder adjustment Moves the device holder.
Electrodes                 These are connected to the device.
Device scale               Used for rough adjustment of the length positioning stage.
Insertion clip             Tightens or loosens an electrode.
Shorting device            (Not shown in Figure 3-1) Used for short compensation.
      Four types of shorting devices are supplied with the 16192A. Use one that has dimensions similar to the DUT.
      When making a shorting device of same dimensions as your DUT, very low residual impedance and a high
      conductivity metal (that is not easily corroded) must be used to construct the shorting device. (It must also be
      clean.)

Magnifying lens                          (Not shown in Figure 3-1) Used when placing a small device
                                         within the electrodes.
Warning              DO NOT look at the sun through the magnifying glass.
                     DO NOT operate or leave the magnifying glass under direct sunlight.

3-2    Operation
How to set the SHORT condition, and the OPEN condition
Setting the SHORT condition




   The names of each part are listed above.               1. Loosen the three knobs.




   2. Move stage A and the two device holders to the      3. Adjust stage C so that the shorting device is placed
   outside.                                               on position 
.
                                                                       s




   4. Place the shorting device so that it contacts the   5. Adjust the two B stages and the two device holders
   electrode.                                             to hold the shorting device.



                                                                                                       Operation    3-3
      6. Tighten the two B knobs to x the B stages and the 7. 
 Push the lever. 
 Slide stage A while pushing
                                                               1                   2
      device holders.                                       the lever until the electrode on the stage A slightly
                                                            contacts the shorting device.




      8. Tighten knob A while pushing the lever.              9. Release the lever to hold the shorting device.


Setting the OPEN condition




      1. Set the DUT on the test xture just as you set the   2. Push the black lever and remove the DUT.
      shorting device in the SHORT compensation.




3-4   Operation
How to connect the DUT




  1. Push the lever and place the DUT on the electrode. 2. Release the lever to hold the DUT.




                                                                                                Operation   3-5
                                                                                              4
Service
Introduction
This chapter covers the following subjects:
  General Information
  Assembly Replacement
     Disassembly Procedure for main assembly
     Replaceable Parts
  Troubleshooting
Warning        These servicing instructions are for use by qualied personnel only. Do
               NOT perform any servicing (other than that contained in the operating
               section) unless you are qualied to do so.

Caution        When you repair the 16192A, put on lint-free groves to avoid contaminating
               inner parts of the 16192A. Agilent Technologies supplies lint-free groves
               (Agilent part number 9300-0163).




General Information
Table 4-1 shows all items included with the 16192A Parallel Electrode SMD Test Fixture.




                                                                                    Service   4-1
                                Figure 4-1. 16192A Product Overview
                                 Table 4-1. 16192A Product Overview
    Reference           Agilent Part
    Designator           Number             Qty.                  Description
        1              (not assigned)       1     Main Assembly
        2               16193-60002         1     Magnifying Glass
        3               16192-09002         1     Insulator
        4                8710-2081          1     Tweezers
        5               16191-29001         1     Shorting Device (12122.4 mm)
        6               16191-29002         1     Shorting Device (1.622.422 mm)
        7               16191-29003         1     Shorting Device (2.422.423.2 mm)
        8               16191-29004         1     Shorting Device (2.422.424.5 mm)
        9                1540-0692          1     Case for shorting devices
        -               16191-29021         1     Styrofoam Holder1
        -               16192-90030         1     Operation and Service Manual1

1     Not shown in the gure.




4-2   Service
Assembly Replacement
This section includes Disassembly and Assembly Procedures and Replacement Parts for the
Main Assembly.

Disassembly and Assembly Procedure
This section contains the information required to disassemble and assemble the Main Assembly.
Length Positioning Stage Assembly Removal:

1. Loosen the Length Locking Knob (\1" in Table 4-3).
2. Remove the Length Positioning Stage Assembly (\1" in Table 4-2).
Width Positioning Stage Assembly Removal:

1. Loosen each Width Positioning Knob (\1" in Table 4-5).
2. Remove each Width Positioning Stage Assembly (\3" and \4" in Table 4-2).
3. Remove the Device Stage (\2" in Table 4-2).




                                                                                   Service   4-3
Replaceable Parts
Table 4-2 through Table 4-5 show and list the replaceable parts for the 16192A. The parts listed
can be ordered from your nearest Agilent Technologies Oce. Ordering information must
include the Agilent part number and the quantity required.




                      Figure 4-2. Replaceable Parts for Main Assembly
                     Table 4-2. Replaceable Parts for Main Assembly
 Reference        Agilent Part
 Designator        Number            Qty.                    Description
        1         (not assigned)         1      Length Positioning Stage Assembly
        2          16192-09001           1      Device Stage
        3         (not assigned)         1      Width Positioning Stage Assembly
        4         (not assigned)         1      Width Positioning Stage Assembly
        5         (not assigned)         1      Test Stage Assembly



4-4   Service
         Figure 4-3. Replaceable Parts for Length Positioning Stage Assembly
         Table 4-3. Replaceable Parts for Length Positioning Stage Assembly
Reference       Agilent Part
Designator        Number           Qty.                    Description
     1          16192-24006         1     Length Locking Knob
     2          16192-20002         1     Length Positioning Stage Block
     3          16192-23001         2     Nut
     4          16192-01202         1     Contact
     5           0515-2421          2     Screw M1.4L3
     6         (not assigned)       1     Insertion Clip Assembly
     7           3050-1066          2     Washer
     8           2190-0654          2     Washer
     9           0515-0976          2     Screw Pan Head M2L6
    10          16192-25004         1     Rod




                                                                               Service   4-5
                Figure 4-4. Replaceable Parts for Insertion Clip Assembly
                Table 4-4. Replaceable Parts for Insertion Clip Assembly
 Reference       Agilent Part
 Designator        Number           Qty.                      Description
        1         0520-0133           1      Screw
        2         2190-0014           1      Washer
        3        16092-40010          1      Holder
        4        16092-40016          1      Holder
        5        16092-40011          1      Lever
        6        16092-23010          1      Shaft
        7         1460-0352           1      Spring




4-6   Service
         Figure 4-5. Replaceable Parts for Width Positioning Stage Assembly
         Table 4-5. Replaceable Parts for Width Positioning Stage Assembly
Reference      AgilentPart
Designator       Number            Qty.                    Description
    1          16192-24006         2      Width Positioning Knob
    2          16192-24005         2      Device Holder Adjustment Knob
    3          16192-24004         2      Holder
    4          16192-25002         1      Device Holder L
    5          16192-25003         1      Device Holder R
    6           0515-0994          2      Screw Flat Head M2L6




                                                                              Service   4-7
                Figure 4-6. Replaceable Parts for Test Stage Assembly


4-8   Service
               Table 4-6. Replaceable Parts for Test Stage Assembly
Reference      Agilent Part
Designator      Number            Qty.                     Description
    1            0515-0914            4       Screw Flat Head M3L6
    2           16192-00201           1       Table
    3           16192-00603           1       Plate
    4           16192-01201           2       Angle
    5           16192-60001           1       Contact Assembly
    6           16192-24013           3       Nut
    7            0515-0952            3       Screw Flat Head M2L4
    8            1250-0907            1       Contact-RF Connector

Caution      If your 16192A test xture was manufactured earlier than 1996 and you need
             to replace either the plate (Figure 4-7: 3) or the contact assembly (Figure 4-7:
             5), it will be necessary to buy replacements for both parts (Figure 4-6: 3
             and 5) since they were modied at the same time. Neither of the new parts
             (Figure 4-6: 3 and 5) can be tted to the other obsolete parts (Figure 4-7: 3 and
             5).




                     Figure 4-7. Obsolete parts manufactured earlier than 1996




                                                                                   Service   4-9
Troubleshooting
This section includes the functional check procedure used to troubleshoot the 16192A Parallel
Electrode SMD Test Fixture.

Open Impedance Check
1. Adjust the electrode distance for connecting the 12122.4 mm Shorting Device (PN
   16191-29001).
   (Refer to Figure 4-8.)




                             Figure 4-8. Shorting Device Position
2. Place the xture on the calibrated APC-7
 terminal of the 4291B RF Impedance/Material
                                            R
   Analyzer.
3. Set the 4291B RF Impedance/Material Analyzer as follows:
   Measurement Parameter              Cp (parallel capacitance)
   Start Frequency                    100 MHz
   Stop Frequency                     1 GHz
   OSC Level                          0.12 V
   Number of Point                    2
   Point Averaging Factor             16
   Point Averaging                    ON
4. Perform a single sweep measurement.
5. Read Cp value at 100 MHz and 1 GHz.
The guideline for the open impedance value is as follows:

4-10   Service
                      Table 4-7. Open Impedance Value Guideline
              Parameter       Frequency       Guideline (absolute value)
                 Cp            100 MHz             750 fF 6 300 fF
                 Cp              1 GHz             750 fF 6 300 fF


Short Impedance Check
1. After the Open Impedance Check is completed, put the 12122.4 mm Shorting Device (PN
   16191-29001) between the electrodes (refer to Figure 4-8).
2. Set the 4291B RF Impedance Analyzer as follows:
   Measurement Parameter             Ls (series inductance)
   Start Frequency                   100 MHz
   Stop Frequency                    1 GHz
   OSC Level                         0.12 V
   Number of Point                   2
   Point Averaging Factor            16
   Point Averaging                   ON
3. Make a single sweep measurement.
4. Read Ls value at 100 MHz and 1 GHz.
The guideline of the short impedance value is as follows:
                      Table 4-8. Short Impedance Value Guideline
              Parameter       Frequency        Guideline (absolute value)
                  Ls           100 MHz              4.5 nH 6 1.5 nH
                  Ls             1 GHz              4.5 nH 6 1.5 nH


Short Impedance Repeatability Check
1. After the Short Impedance Check is completed, remove the Shorting Device and put it back
   on the same place again (refer to Figure 4-8).
2. Make a single sweep measurement with the same measurement conditions.
3. Read Lp value at 100 MHz and 1 GHz and check the value is within the Short Impedance
   Value Guideline described in Table 4-8.
4. Calculate the dierence between the rst Ls measurement value and second Ls
   measurement value at each frequency.
The guideline for the short impedance repeatability is as follows:
                   Table 4-9. Short Impedance Repeatability Guideline
              Parameter        Frequency         Guideline (dierence)
                  Ls            100 MHz                 6 45 pH
                  Ls             1 GHz                  6 20 pH




                                                                                 Service   4-11
              REGIONAL SALES AND SUPPORT OFFICES
For more information about Agilent Technologies test and measurement products, applications, services, and
for a current sales office listing, visit our web site: http://www.agilent.com/find/tmdir. You can also contact one
of the following centers and ask for a test and measurement sales representative.                          11/29/99


United States:                           (fax) (61 3) 9272 0749
Agilent Technologies                     (tel) 0 800 738 378 (New Zealand)
Test and Measurement Call Center         (fax) (64 4) 802 6881
P.O.Box 4026
Englewood, CO 80155-4026                 Asia Pacific:
(tel) 1 800 452 4844                     Agilent Technologies
                                         24/F, Cityplaza One, 1111 King's Road,
Canada:                                  Taikoo Shing, Hong Kong
Agilent Technologies Canada Inc.         (tel) (852)-3197-7777
5150 Spectrum Way                        (fax) (852)-2506-9284
Mississauga, Ontario
L4W 5G1
(tel) 1 877 894 4414

Europe:
Agilent Technologies
Test & Measurement
European Marketing Organization
P.O.Box 999
1180 AZ Amstelveen
The Netherlands
(tel) (31 20) 547 9999

Japan:
Agilent Technologies Japan Ltd.
Call Center
9-1, Takakura-Cho, Hachioji-Shi,
Tokyo 192-8510, Japan
(tel) (81) 426 56 7832
(fax) (81) 426 56 7840

Latin America:
Agilent Technologies
Latin American Region Headquarters
5200 Blue Lagoon Drive, Suite #950
Miami, Florida 33126
U.S.A.
(tel) (305) 267 4245
(fax) (305) 267 4286

Australia/New Zealand:
Agilent Technologies Australia Pty Ltd
347 Burwood Highway
Forest Hill, Victoria 3131
(tel) 1-800 629 485 (Australia)
16192-90030



◦ Jabse Service Manual Search 2024 ◦ Jabse PravopisonTap.bg ◦ Other service manual resources online : FixyaeServiceinfo