Troubleshooting and Repair Manual
                           Volume 1


HP 85660B Spectrum Analyzer RF Section




                      ri!ia   HEWLETT
                              PACKARD

    HP Part No. 85660-90210    Microfiche Part No. 85660-90211
                 Printed in USA December 1990
@Copyright Hewlett-Packard Company 1990
All Rights Reserved. Reproduction, adaptation, or translation without prior written
permission is prohibited, except as allowed under the copyright laws.
1212 Valley House Drive, Rohnert Park, CA 94928-4999, USA
Certification
Hewlett-Packard Company certifies that this product met its published specifications at the
time of shipment from the factory. Hewlett-Packard further certifies that its calibration
measurements are traceable to the United States National Institute of Standards and
Technology, to the extent allowed by the Institute's calibration facility, and to the calibration
facilities of other International Standards Organization members.




Warranty
This Hewlett-Packard instrument product is warranted against defects in material and
workmanship for a period of one year from date of shipment. During the warranty period,
Hewlett-Packard Company will, at its option, either repair or replace products which prove to
be defective.
For warranty service or repair, this product must be returned to a service facility designated
by HP. Buyer shall prepay shipping charges to HP and HP shall pay shipping charges to
return the product to Buyer. However, Buyer shall pay all shipping charges, duties, and taxes
for products returned to HP from another country.
HP warrants that its software and firmware designated by HP for use with an instrument
will execute its programming instructions when properly installed on that instrument. HP
does not warrant that the operation of the instrument, or software, or firmware will be
uninterrupted or error-free.

Limitation of Warranty
  The foregoing warranty shall not apply to defects resulting from improper or inadequate
  maintenance by Buyer, Buyer-supplied software or interfacing, unauthorized modification or
  misuse, operation outside of the environmental specifications for the product, or improper
  site preparation or maintenance.
  NO OTHER WARRANTY IS EXPRESSED OR IMPLIED. HP SPECIFICALLY
  DISCLAIMS THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS
  FOR A PARTICULAR PURPOSE.

Exclusive Remedies
  THE REMEDIES PROVIDED HEREIN ARE BUYER'S SOLE AND EXCLUSIVE
  REMEDIES. HP SHALL NOT BE LIABLE FOR ANY DIRECT, INDIRECT, SPECIAL,
  INCIDENTAL, OR CONSEQUENTIAL DAMAGES, WHETHER BASED ON
  CONTRACT, TORT, OR ANY OTHER LEGAL THEORY.




Assistance
Product maintenance agreements and other customer assistance agreements are available for
Hewlett-Packard products.
For any assistance, contact your nearest Hewlett-Packard Sales and Service Office.

                                                                                                    ...
                                                                                                    iii
Safety Symbols
The following safety symbols are used throughout this manual. Familiarize yourself with each
of the symbols and its meaning before operating this instrument.

Caution        The caution sign denotes a hazard. It calls attention to a procedure which,
               if not correctly performed or adhered to, could result in damage to or
               destruction of the instrument. Do not proceed beyond a caution sign until the
     u         indicated conditions are fully understood and met.


Warning        The warning sign denotes a hazard. It calls attention to a procedure which,
               if not correctly performed or adhered to, could result in injury or loss of life.
               Do not proceed beyond a warning sign until the indicated conditions are fully
     Q         understood and met.




General Safety Considerations
Warning        Before this instrument is switched on, make sure it has been properly grounded
               through the protective conductor of the ac power cable to a socket outlet
               provided with protective earth contact.
     9
               Any interruption of the protective (grounding) conductor, inside or outside
               the instrument, or disconnection of the protective earth terminal can result in
               personal injury.


Warning        There are many points in the instrument which can, if contacted, cause personal
               injury. Be extremely careful.
               Any adjustments or service procedures that require operation of the instrument
               with protective covers removed should be performed only by trained service
               personnel.


Caution        Before this instrument is switched on, make sure its primary power circuitry
               has been adapted to the voltage of the ac power source.
               Failure to set the ac power input to the correct voltage could cause damage to
               the instrument when the ac power cable is plugged in.




iv
Contents


Volume 1
General Information     General information on the contents of the manual, including storage,
                        shipment, and packaging.
Overall                 Troubleshooting index, special messages, diagnostic functions, error
Troubleshooting         correction routine, sweep system block diagram and troubleshooting,
                        mnemonics listing, and spectrum analyzer overall block diagram.
Analog                  Phase lock loop operation, start frequency tuning equations, and phase
Troubleshooting         lock troubleshooting.
Digital                 Instrument preset checks, digital storage verification, and RF digital
Troubleshooting         troubleshooting block diagram.
A5 Front Panel          Service sheets containing circuit descriptions, troubleshooting
through A8              information (if applicable), replacement procedures (if applicable),
Rectifier/AS Power      replaceable parts lists, parts identification (if applicable), block
Line Module             diagrams, component locations, and schematic diagrams.

Volume 2
A10 20/30               Service sheets containing circuit descriptions, troubleshooting
Synthesizer through     information (if applicable), replacement procedures (if applicable),
A23 Motherboard         replaceable parts lists, parts identification (if applicable), block
                        diagrams, component locations, and schematic diagrams.
General Parts Listing   Replaceable parts information, reference designations and
                        abbreviations, manufacturer's code list, RF miscellaneous parts list,
                        RF assemblies parts list, and instrument parts identification.
Major Assembly and RF section major assembly and component locations.
Comuonent Locations




                                                                                    Contents 1
General Information


Introduction
This volume of the Troubleshooting and Repair Manual contains information for the
troubleshooting and repair of the RF Section of the instrument. This information is combined
in service sheets and indexed with tabs for quick reference. Also contained in this volume
are overall troubleshooting information and illustrations of the instrument useful in isolating
failures to the RF or IF-Display Section

Instruments Covered by This Manual
This Troubleshooting and Repair manual contains information for the servicing of all
HP 85660B RF Sections with serial number prefixes of 2410A and above. The assemblies of
the HP 8566AB Retrofit Kit (HP 8566A to HP 8566B Retrofit Kit) are also covered in this
manual. The following HP 85660B RF Sections Options are covered in this manual.
n   Option 001 (75fl Input)
n   Option 400 (400 Hz Operation)
n   Option 462 (Impulse Bandwidths)
Changes that are made to the HP 85660B after the printing of this manual will be included in
an update supplement.
The HP 85660B RF Section is used with the HP 85662A IF-Display Section as the HP 8566B
Spectrum Analyzer. The HP 85660B RF Section is used with the HP 85662A Option 462
IF-Display Section as the HP 8566B Option 462 Spectrum Analyzer.

Service Sheets
The service sheets in this manual are organized in alphanumeric order and are indexed with
tabs to make it easy to locate a specific service sheet. Each of the service sheets contain the
following information:
w Circuit Description (where practical)
n   Replacement Procedure (where practical)
w Troubleshooting Hints (where practical)
w Replaceable Parts List
n   Component Location Illustration
w Parts Identification (where practical)
n   Block Diagram (where practical)

                                                                           General Information 1
n   Schematic Diagram

Replacement Procedures
Replacement procedures are included for use in removing and replacing assemblies for repair.
They are located in the following sections:
w A5 Front Panel
     Front Panel Removal and Repair
w A6 RF Module
     A6 RF Module Replacement
     A6Al Coaxial Switch and A6A17 300 MHz BPF Replacement
     A6A2 RF Attenuator Replacement
     A6A4 Second Converter Replacement
     A6A6 First Converter Replacement
     A6A15 3.6 GHz BPF, A6A16 1.5 GHz
     LPF, and A6A18 LPF Replacement
n   A6A3 Last Converter
     A6A3 Last Converter Replacement
H A6A7 YTX Current Driver/A6A5 ACLU/A6A8 YTX
     A6A5 Amplifier/Coupler/Load Unit
     (ACLU) Replacement
     A6A7 YTX Current Driver Replacement
     A6A8 YTX Replacement
w A7M/N-Reference
     A7 M/N-Reference Replacement
H A8 Rectifier/A9 Power Line Module
     RF Section Internal Fuse Replacement
     Transformer Replacement
     Power Transistor Replacement
n   All YTO Loop
     All YTO Loop and AllA3 YTO
     (2.0 to 6.2 GHz Oscillator) Replacement
n   Al7 Positive Regulator
     RF Section Internal Fuse Replacement
n   Al8 Negative Regulator
     RF Section Internal Fuse Replacement




2 General Information
Major Assembly and Component Locations
Major assembly and component location illustrations for the RF Section are located at the
rear of this manual.

Troubleshooting
Troubleshooting information for the RF Section is divided into three levels as follows:
W Instrument Level
     Spectrum Analyzer Overall Troubleshooting
w Section Level
     RF Section Analog Troubleshooting
     RF Section Digital Troubleshooting
     A6 RF Module
     A7 M/N-Reference/A22 10 MHz Frequency Standard
     A10 20/30 Synthesizer
     All YTO Loop
n   Assembly Level
      Most assemblies have troubleshooting hints immediately following circuit descriptions.
      Troubleshooting information is also located on assembly level block diagrams, notes, and
      schematics.
All assemblies are indexed by tab except for the ones listed below. The index tab they can be
found under is also listed.

                                 Table 1. Assembly Locations

                          Assembly                    Location

                          A24        I   General Parts Listing               I
                          Tl             A8 Rectifier/AS Power Line Module


Printed Circuit Board Edge Connector Contact Cleaning

Materials
w Lint-free cloth or equivalent (HP Part Number 9310-0039, Check Digit 3).
w Solution of 80% electronics-grade isopropyl alcohol and 20% water.
w Static-free work station.

Procedure
1. Dampen the cloth with the alcohol and water solution and scrub the edge connector
   contacts vigorously, using a circular motion. Polish one side of the board at a time until
   the contacts shine, keeping the cloth damp to dissolve contaminants and reduce static
   electricity.



                                                                                 General Information 3
2. Using a clean cloth, dry the contacts by wiping from their inside to outside edge. This
   prevents particles from building up on the contact edges.

Caution         Do not use erasers to clean the edge connectors. They cause microscopic
                damage to the contact surface, removing the thin gold plating and exposing
                the nickel underplating, which eventually corrodes. Erasers also leave a film on
  9             the contact and generate static electricity.
                Do not use paper of any kind to clean the edge connector contacts. Paper or
                lint particles left on the edge contact surface can cause intermittent electrical
                connections.
                Do not touch contact or trace surfaces with bare hands. Always handle the
                board by its edges.


HP-IB Address Selection
The HP-IB address for the HP 8566B is preset at the factory by means of a five-segment
binary switch located on the Al5 Controller Assembly. This switch is set to the binary
number 11111 which corresponds to a decimal equivalent of 31. The number 31 is a special
instruction code that commands the instrument to use the last input address stored in
memory. This stored HP-IB address is ASCII 2R (decimal 18) and determines the address to
                                                        l
be used on "power up."
The HP-IB address may be changed to any of the addresses listed in Table 2 by resetting the
HP-IB address switch to correspond to the binary equivalent of the desired ASCII character
or decimal value as indicated in the table. The five-segment switch is illustrated in Figure 1
and is shown in its preset position (decimal 31).




4 General Information
Table 2. Cross-Reference Between ASCII, Decimal, and Binary Address
                              Codes
        ASCII Character Decimal Value 5-Bit Binary Equivalent

        @       SP            00               00000

        A        !            01               00001

        B       "             02               00010

        C       #             03               00011

        D       $             04               00100

        E       %             05               00101

        F       &             06               00110

        G        '            07               00111

        H        (            08               01000

        I        >            09               01001

        J       *             10               01010

        K       +             11               01011

        L        '            12               01100

        M       -             13               01101

        N        .            14               01110

        0       /             15               01111

        P       0             16               10000

        Q       1             17               10001

        R       2             18               10010

        S       3             19               10011

        T       4             20               10100

        U       5             21               10101

        V       6             22               10110

        W       7             23               10111

        X       8             24               11000

        Y       9             25               11001

        Z                     26               11010

            [    ;            27               11011

        \       <             28               11100

        ]       =             29               11101

        ?       >             30               11110




                                                           General Information 5
                                                                    A6       A5       A4       A3       A2       Al
                                                               I
                        Switch in
                        Down Position
                        = Logic 1

                         Indicates Switch
                         in Down Position


                      Figure 1. HP-IB Address Switch (Shown in Factory Preset Position)

The HP-IB address may also be changed from the front panel or programmed via a controller
using a special shift key function (KSP). This address remains in effect as long as the
instrument memory has power from either the ac line or the internal battery. However, if
this stored address is lost, the default address is the factory preset decimal 18 (ASCII 2R).
For additional information on the HP-IB address, refer to the Operating and Programming
Manual.

Storage and Shipment

Environment
The instrument may be stored or shipped in environments within the following limits:
  Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -40