Text preview - extract from the document
Agilent AN 1310
Mobile Communications Device Testing
Application Note




Considerations when selecting a System Power Supply for Mobile
Communications Device Testing


                                   Abstract
                                   Pulsed battery drain currents, reg-
                                   ulated charge currents, and remote
                                   DUT (Device Under Test) fixtures,
                                   dictate the need for specialized
                                   power sourcing, loading, and meas-
                                   urement capabilities for testing
                                   mobile communications devices.
                                   Many of these capabilities are not
                                   available in general-purpose system
                                   power supplies.

                                   This guide will assist the test sys-
                                   tem designer in selecting a system
                                   power supply by properly evaluat-
                                   ing test system and power supply
                                   needs that are unique to the appli-
                                   cation and not immediately obvi-
                                   ous. In this way, many problems
                                   likely to arise in production can be
                                   avoided.
Overview
Mobile Communications System Power Supplies


The growth of the mobile communica-         In the production testing of mobile        Section One
tions market is clearly in the newer        communications products, a system          Considerations when Sourcing Power to
digital wireless products. The con-         power supply replaces the battery.         the DUT
sumer advantages are significant--          High volume manufacturing often dic-       A. Transient Voltage Drop at the DUT
improved transmission quality, acces-       tates that the DUT fixture is remotely        Fixture
sibility, security, and operating time.     located from the test system, intro-
                                            ducing significant impedance due to        B. Pulsed Current Sourcing for DUT
Digital mobile communications               long wiring length. This, in combina-         Transmit Burst Current Drain
devices transmit in short bursts            tion with pulsed current drain, makes
which conserves power between               it challenging to maintain a stable,       Section Two
transmissions, thus extending talk          transient-free voltage at the fixture      Considerations when Loading the DUT
time of the battery. Likewise, during       just as if the DUT were operating          Battery Charger
standby, some digital devices also          directly from a battery. In addition to    A. Constant Voltage Loading
"wake up" and listen for incoming           emulating the battery, the power sup-         Capability
calls in short bursts, again extending      ply can also provide current and volt-
battery life. The resulting battery         age measurements required for test-        Section Three
drain is pulsed current, ranging from       ing and calibrating the DUT.               Considerations when Making DUT Current
milliamperes to amperes. Accurate                                                      Measurements
current drain measurements are              All of these things dictate the need       A. Talk-mode Current Drain
important to assure proper battery          for a system power supply with power          Measurements
life for these different operating          sourcing, loading, and measurement
modes.                                      capabilities specially tailored for this   B. Standby-mode Current Drain
                                            application. By properly evaluating           Measurements
Mobile communications devices incor-        these unique needs of the test system
porate a wide variety of battery            and power supply, the test system
                                                                                       C. Off-mode Current Leakage
charging schemes. Constant and              designer can avoid production test
                                                                                          Measurement
pulsed charge currents ranging from         problems by selecting a power supply
milliamperes to amperes are charac-         suited for the application.
                                                                                       D. Battery Charger Current
teristic of rapid, slow, and trickle bat-
                                                                                          Measurement
tery charge modes of these devices.         Considerations when Selecting a
There are a variety of charge termina-
tion methods all primarily deter-
                                            System Power Supply                        The following references are useful in
                                            There are several unique needs to          the selection of any system power
mined by battery voltage.
                                            consider in the system current supply      supply:
                                            selection, specific to mobile commu-
                                            nications device testing.                  