Service Manuals, User Guides, Schematic Diagrams or docs for : Agilent Optoelectronic IC Component Evaluation 5991-0015EN c20130528 [2]

<< Back | Home

Most service manuals and schematics are PDF files, so You will need Adobre Acrobat Reader to view : Acrobat Download Some of the files are DjVu format. Readers and resources available here : DjVu Resources
For the compressed files, most common are zip and rar. Please, extract files with Your favorite compression software ( WinZip, WinRAR ... ) before viewing. If a document has multiple parts, You should download all, before extracting.
Good luck. Repair on Your own risk. Make sure You know what You are doing.




Image preview - the first page of the document
Optoelectronic IC Component Evaluation 5991-0015EN c20130528 [2]


>> Download Optoelectronic IC Component Evaluation 5991-0015EN c20130528 [2] documenatation <<

Text preview - extract from the document
                                          Optoelectronic IC/Component Evaluation
                                          Quick Bench-top Evaluation of ICs and Electronic Components
                                          Agilent B2900A Series of Precision
                                          Source/Measure Units facilitates quick
                                          DC evaluation of optoelectronic
                                          components such as optocouplers.
                                                                                                                                   B2912A (front view)           B2912A (rear view)

DC evaluation of optoelectronic IC's/components                                              Measurement examples
 An optoelectronic IC or component typically consists of an emitting device (like an LED)     Example 1: LED forward voltage
 and photo detectors (PDs). This arrangement requires the simultaneous DC evaluation          This is the most basic optoelectronic device measurement. Only one SMU is used to
 of both devices.                                                                             source and measure the LED. The B2900A's graphical display lets you directly view the
 A pair of source/measure units (SMUs) is the ideal choice to make flexible DC                IV curve.
 measurements on both the LED and PD.                                                         Example 2: Input photo diode current transfer ratio
 To illustrate this, two measurement examples of an off-the-shelf optocoupler are outlined    Measuring how efficiently light is transferred from the LED to the PD is essential for
 in this document.                                                                            optocouplers. In this example, SMU1 is used to source forward current to the LED, while
                                                                                              SMU2 monitors the generated current as it changes the reverse bias voltage across PD1.



                                                         Dump to          Organize your
    Set SMUs for DUT           Measurement
                                                       USB memory          quick report                              B2912A                      DUT (HCNR-201)
                                                                               Quick
                                                                             Evaluation
                                                                               Report
                                                                                                                                               1          LED           8
                                                                                                           SMU1                V
                                                                                                                                               2                        7


                                                                                                                               A               3                        6
      What is Quick Bench-top Evaluation?
                                                                                                           SMU2
      The B2900A series does not require a PC to make measurements on the
      bench-top. You can view graphical measurement results on the B2900A and                                                                  4                        5
                                                                                                                                                         PD1    PD2
      save the graphs and data to any USB memory device, thereby improving the
      efficiency of your bench-top evaluation and debugging. Of course, if you
      prefer using a PC to control the B2900A then you can download Agilent's
                                                                                                            DUT and SMU setup
                                                                                                                                                   Note: HCNR-201 is a product of
      free Quick I/V Measurement Software from our website.                                                                                        Avago Technologies
  Example 1: LED forward voltage                                                               Example 2: Input photo diode current transfer ratio



                      SMU1 current                                                                                                                             Cursor aligned to the
                      swept from 0                                                                                                                             maximum value shows
                                                         For the B2900A series,
                      to 25 mA                                                                  SMU2 voltage swept                                             46.47 



◦ Jabse Service Manual Search 2026 ◦ Jabse PravopisonTap.bg ◦ Other service manual resources online : FixyaeServiceinfo