Making Resistance Measurement Using B2901A 02A 11A 12A - Demo Guide 5991-3950EN c20141010 [2]


>> Download Making Resistance Measurement Using B2901A 02A 11A 12A - Demo Guide 5991-3950EN c20141010 [2] documenatation <<

Text preview - extract from the document
Demo Guide
Making Resistance Measurement Using B2901A/02A/11A/12A
B2900A Series Precision Source/Measure Unit

  Procedure Overview                                              Objective                                                                 Required instrument and accessory
  1. Make a resistance measurement                                This demo shows how easily a resistance measurement can
  2. Make an accurate low resistance measurement                  be made with the B2900A Series via easy-to-use Graphical                                                  1.1 k resistor
                                                                  User Interface.

                                                                                                                                            Keysight B2901A/02A/11A/12A     1 k resistor          Keysight 11059A
                                                                                                                                            Precision Source/Measure Unit
                                                                                                                                                                                                  Kelvin Probe Set

Setup-1                                                           1-2. Use AUTO measurement operation                                       Setup-2
1. Connect the yellow banana plug to Ch 1 Low Force terminal.     a. Rotate       to select Resistance measurement operation,               1. Connect the yellow banana plug to Ch 1 Low Force terminal.
2. Connect the red banana plug to Ch 1 High Force terminal.                                                                                 2. Connect the orange banana plug to Ch 1 Low Sense terminal.
3. Clip the one lead of 1 k Resistor with the black gold-plated      and then press        to edit it. Then select         to set           3. Connect the red banana plug to Ch 1 High Force terminal.
   tweezers.                                                         Resistance measurement operation to AUTO.                              4. Connect the brown banana plug to Ch 1 High Sense terminal.
4. Clip the other lead of 1 k Resistor with the red gold-plated                                                                             5. Clip the one lead of 1  Resistor with red gold-plated flat
   tweezers.                                                                                                                                   tweezers.
                                                                                                                                            6. Clip the other lead of 1  Resistor with black gold-plated
                                                                                                                                               tweezers.
                           1 k resistor
                                                                                                                                                                         1  resistor
                        Red             Red
                      (11059A)        (11059A)                    b. Press Ch1        to turn on Channel 1 Output relay.                                                Brown            Red
                                                  4       Brown                                                                                                        (11059A)        (11059A)
               2                                          Brown
                                                          Black   c. Press       to perform a single point measurement.                                        4                                    6
               1                                          Brown                                                                                                                                              Brown
                                                  3       Brown                                                                                                3     Red (11059A)                            Black
                                                                                                  Measurement parameters are
                       Yellow           Black                                                                                                                                                                Black
                                                                                                  updated whenever Trigger Button is                               Orange (11059A) Black (11059A)            Silver
                      (11059A)        (11059A)                                                                                                                 2
                                                                                                  pressed                                                                                                    Brown
                                                                                                                                                               1                                    5
1. Make a resistance measurement                                  d. Press       to repeat single point measurements periodically.
                                                                                                                                                                   Yellow (11059A)
1-1. Change View mode to Single View                                                                    Measurement parameters are
                                                                                                        updated periodically                2. Make an accurate low resistance measurement
a. Press         repeatedly until Single View for Channel 1 is                                                                              2-1. Reset the instrument
   shown in the display.
                                                                                                        "Auto" indicator is turned on       a. Press          ,         and then press                  to
                                                                                                                                               display Confirmation dialogue.
                                                                  e. Press       to stop making measurements periodically.
                                                                                                           "Auto" indicator is turned off
                                                                                                                                                                                                  (1) Press More...


                                                                  1-3. Turn off the channel output                                                                                                (2) Press System

                                                                  a. Press Ch1        to turn off Channel 1 Output relay.
                                                                                                                                                                                                  (3) Press Reset
Keysight | Making Resistance Measurement Using B2901A/02A/11A/12A 