Service Manuals, User Guides, Schematic Diagrams or docs for : Agilent N2830A Series InfiniiMax III+ Probes Configuration Card N2830-92000 c20140623 [2]

<< Back | Home

Most service manuals and schematics are PDF files, so You will need Adobre Acrobat Reader to view : Acrobat Download Some of the files are DjVu format. Readers and resources available here : DjVu Resources
For the compressed files, most common are zip and rar. Please, extract files with Your favorite compression software ( WinZip, WinRAR ... ) before viewing. If a document has multiple parts, You should download all, before extracting.
Good luck. Repair on Your own risk. Make sure You know what You are doing.




Image preview - the first page of the document
N2830A Series InfiniiMax III+ Probes Configuration Card N2830-92000 c20140623 [2]


>> Download N2830A Series InfiniiMax III+ Probes Configuration Card N2830-92000 c20140623 [2] documenatation <<

Text preview - extract from the document
                   Keysight N2830A-Series InfiniiMax III+ Probes                                          Connecting the Probe to the In niium Scope
                                                                                                          To Connect                                                 To Disconnect
Locate the User's Guide                                                                                   1. With the lever in relaxed in position push the probe    Move and hold the lever at R
                                                                                                          onto the BNC.                                              (Release) and pull the probe
  Download the user's guide from the        Read the user's guide in Keysight's Probe Resource Center                                                                from the BNC.
                                                                                                          2. The lever moves towards the R (release)  and returns
  probe's product page on
  www.keysight.com.
                                            (PRC). The PRC is an application that runs on a PC, Mac, or
                                            iOS device. Available at www.keysight.com/ nd/PRC.
                                                                                                           
                                                                                                          to     symbol.
                                                                                                          3. Move the lever towards the   symbol until snug.
CAUTION. Risk of Damage Due to Electrostatic Discharge (ESD)                                                                                                                          

 This probe is a high-performance device that ESD can quickly and imperceptibly damage or destroy.
 Always work at a static-safe workstation and wear a wrist strap when handling probe components.
 Refer to the User's Guide. To connect the probe to the oscilloscope, follow these four steps:
        If the DUT is not grounded                       Connect the probe                                Additional Accessories
  1 to the oscilloscope via the                  2 head to the DUT.
        AC mains ground, connect                         The probe
the DUT ground to the oscillo-                 ampli er must not be                                        N1022B for connecting the In niiMax III+ probing system to In niium 86100D DCA-X
scope ground. An example of a                  connected to the                                            sampling oscilloscope or other RF instruments.
  oating ground is a battery-                  oscilloscope or the probe head!
                                                                                                           N2787A 3D probe positioner for holding the browser or probe ampli er.
powered DUT.
                                                                                                           Strain relief putty (N5439-65201).
                                                                      Connect the
                                                                3     probe ampli er                       N5450B Extreme Temp. Extension Cable. See user's guide for more information.
                                                          1


         1
                                                          2
                                                                      to the oscillo-                      E2655C or N5443A PV Fixture. Required to calibrate, deskew, and verify the
         2
                                                          3
                                                               scope. Do not connect                       performance of the probe. Properly positions the probe for performance veri cation
         3
                                                          4
                                                               the probe head to the                       testing.
         4
                               Probe Comp
                                                               ampli er at this time.

                                                                                Probe Ampli er            In niiMax III+ Probe Compatibility
                                        4 Connect the
                                          probe head to                                     Probe Head

                                   the probe ampli er.                                                    Compatible Oscilloscopes                       Not Compatible
When probing, you can                                                                                       90000 X/Q Series (with N5442A adapter)          9000 and In niiVision scopes
move the probing site without
breaking the head-to-ampli er                                                                               90000A Series                                   N2830/1/2A In niiMax III+ probes are
connection. EXCEPTION: break the                                                                                                                            not compatible with In niiMax I and
                                                                                                            S Series
connection before moving an                                                                                                                                 II probe heads and vice versa.
                                                                                                            86100C/D Series (with N1022A/B
N2836A or N5441A solder-in probe
                                                                                                            adapter)
head.
Recommended Probe Configurations            See user's guide for detailed information.    3 N5439A ZIF Probe Head                                     4 N5444A 2.92 mm/3.5 mm
                                                                                                                                                                  SMA Head
1 N5445A Differential Browser               2 N2848A QuickTip Probe Head
                                                                                                                          N5439A                                  ii M o
                                                                                                                                                           fi n




                                                                                                                                                                       de
                                                                                                                                                      In
                                                         ii M o
                                                  fi n
                                                                       N2848A




                                                              de
                                            In




                                                                                                                                                      Co




                                                                                                                                                                           d
                                                                                                                                                       m




                                                                                                                                                                       ea
                                                                                                                                                           p ati le H
                                                                                                                      ZIF tips                                  b




                                            Co




                                                                  d
                                              m




                                                              ea
                                                  p ati le H                                                 N2838A            N5440A
                                                       b
                                                                                                                                                       BW up to 28 GHz
                                                                                                                                                       Connect two 2.92 mm, 3.5 mm, SMA
                                                                           N2849A                                                                      cables to make a di erential measure-
                                                                                                                                                       ment on a single oscilloscope channel.
                                                                                                                                                       Accessory: N5448A 2.92 mm exible
                                                                                                                                                       cables (25 cm) to extend the cable
                                             In niiMode. Di erential, common mode,                                                                     length.
  BW up to 30 GHz                            single-ended measurements without
                                             changing connections.
  Replacement tips, ground blades and
  ground screws available                    BW: 16 GHz Di , 10 GHz CM, 10 GHz SE                                                                     5 N2836A InfiniiMode
                                                                                            N2838A: 25 GHz BW, normal sensitivity                                 Solder-In Probe Head
                                             Easy, secure magnetic connection between
  Best handheld probe for di erential and                                                   N5440A: 28 GHz BW, normal sensitivity
                                             head and tip.
  single-ended signals
                                                                                            N5447A: not compatible with In niiMax III+                            ii M o
                                             Extreme temperature environments.                                                                             fi n
  Spring-loaded tips and variable spacing




                                                                                                                                                                       de
                                                                                            ampli ers




                                                                                                                                                      In
  (0.5 mm to 3.1 mm, use thumbwheel to       Accessory: 4 QuickTips (N2849A)
  adjust)                                                                                   5 PC Board ZIF tips (N2838A)




                                                                                                                                                      Co




                                                                                                                                                                           d
                                                                                                                                                       m




                                                                                                                                                                       ea
                                                                                                                                                           p ati le H
                                                                                            5 Ceramic ZIF tips (N5440A)                                         b
  Accessory: 4 replacement tips (N5476A)
  Accessory: 4 replacement ground blades
                                            6 N5441A Solder-In Probe Head                   Economical replaceable tip form factor
  (N5445-68700)                                                                             Choice of 450 (normal sensitivity) or
                                                                                            200 ZIF tips (high sensitivity)
  Accessory: 4 replacement ground screws                                                                                                               In niiMode. Di erential, common
  (N5445-68701)                                                                             Variable spacing                                           mode, single-ended measurements
                                                                                                                                                       without changing connections.
  Using the N2787A 3D probe positioner                                                      N2838A replacement axial resistors:
  with the N5445A browser probe head         BW up to 16 GHz, variable span                  N2836-68701                                               BW up to 26 GHz, variable span
  reduces the chance of browser tips         Economical, semi-permanent connection                                                                     Economical, semi-permanent
  breakage and ensures that the tips         Extra wire accessory: 7 mil (01169-81301),                                                                connection
                                                                                          Keysight Technologies (N2830-92000) April 2014, Edition 2
  maintain solid contact.                    5 mil (01169-21306 ).                                                                                     Replacement axial resistors:
                                                                                           *N2830-92000*                                                N2836-68701



◦ Jabse Service Manual Search 2026 ◦ Jabse PravopisonTap.bg ◦ Other service manual resources online : FixyaeServiceinfo